10kV three-phase epoxy-resin dry-type transformer
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 10kv three-phase epoxy-resin dry-type transformer in China. If you're going to buy customized 10kv three-phase epoxy-resin dry-type transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
introduction of 10kV three-phase epoxy-resin dry-type transformer
GNEE TRANSFORMER supplies 10kV cast resin dry-type Transformer.
Epoxy-resin dry-type transformers are commonly used in applications where fire safety is a concern, as they are less likely to cause a fire than oil-filled transformers. They also have lower maintenance requirements, as there is no need to monitor oil levels or perform oil tests.
Dry transformers come in a range of sizes and voltages and can be used in various applications, including power distribution, lighting, and control circuits. They are particularly suited for indoor use, such as in hospitals, schools, and office buildings, where their low noise levels and low emissions make them a popular choice.
three-phase epoxy-resin dry-type transformer Advantages
- Standards: Compliant with GB, IEC, GOST, EN, NF, ANSI/IEEE (can be customized according to customer-specified standards)
- Certifications: ISO, CE, IEC, SABS, COC, CSA, UL
- Efficiency: The efficiency of the 33kV dry-type transformer can reach over 99%
- Maintenance-Free: With IP23 protection class and Class F1 insulation, it features safer and superior fire resistance, and has a design life of more than 25 years
- Overload Capacity: Equipped with a complete temperature protection and control system, it can operate at 120% of the rated load under forced air cooling conditions
10KV three-phase epoxy-resin dry-type transformer Technical Parameters
Input Voltage: 10KV
Output Voltage: 0.4KV
Capacity: 30-2500KVA
Remarks: Voltage, capacity, frequency, connection group and loss can all be customized according to customer requirements
| Capacity | Rated voltage&Off-load tapping | Vector Group |
NO-load loss(W) |
Load loss (W)F |
NO-load current(%) |
Short circuit impedance(%) |
||||
| H.V(kv) | High pressure Tap range(%) |
L.V(kv) | ||||||||
| 30 | 11 10.5 10 6.6 6.3 6 |
±5% ±2.5% |
0.4 0.69 |
Dyn11 Yyn0 |
150 | 710 | 2 | 4 | ||
| 50 | 215 | 1000 | 2 | 4 | ||||||
| 80 | 295 | 1380 | 1.5 | 4 | ||||||
| 100 | 320 | 1570 | 1.5 | 4 | ||||||
| 125 | 375 | 1850 | 1.3 | 4 | ||||||
| 160 | 430 | 2130 | 1.3 | 4 | ||||||
| 200 | ±5% ±2x2.5% |
495 | 2530 | 1.1 | 4 | |||||
| 250 | 575 | 2760 | 1.1 | 4 | ||||||
| 315 | 705 | 3470 | 1 | 4 | ||||||
| 400 | 785 | 3990 | 1 | 4 | ||||||
| 500 | 930 | 4880 | 1 | 4 | ||||||
| 630 | 1070 | 5880 | 0.85 | 4 | ||||||
| 630 | 1040 | 5960 | 0.85 | 6 | ||||||
| 800 | 1215 | 6960 | 0.85 | 6 | ||||||
| 1000 | 1415 | 8130 | 0.85 | 6 | ||||||
| 1250 | 1670 | 9100 | 0.85 | 6 | ||||||
| 1600 | 1960 | 11700 | 0.85 | 6 | ||||||
| 2000 | 2440 | 14400 | 0.7 | 6 | ||||||
| 2500 | 2880 | 17100 | 0.7 | 6 | ||||||
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: 10kv three-phase epoxy-resin dry-type transformer, China 10kv three-phase epoxy-resin dry-type transformer manufacturers, suppliers, factory, dry type power transformers, insulation transformer, dry type transformer types, Cast Dry Transformer, Dry distribution transformer, amorphous steel transformer
You Might Also Like
Send Inquiry