Product Introduction
A transformerpole mounted transformer is a device that uses the principle of electromagnetic induction to change the AC voltage. Its main components are the primary coil, secondary coil, and iron core (magnetic core). In electrical equipment and wireless circuits, it is commonly used for voltage regulation, impedance matching, safety isolation, etc.
Characteristics of pillar mounted single-phase transformer
1.Installation method: The column mounted design fixes the transformer through pillars, commonly found on 10-15 meter poles. It adopts a suspended installation method, significantly reducing the footprint and infrastructure investment.
2.Energy efficiency advantage: Compared with three-phase transformers of the same capacity, single-phase column mounted transformers have lower no-load and load losses, especially suitable for dispersed load scenarios such as rural power grids and remote mountainous areas.
3.Structural design:Adopting a fully sealed fuel tank structure, maintenance free operation enhances reliability.
The iron core uses grain oriented silicon steel sheets or amorphous alloy materials to further reduce no-load losses and noise.
Parameter List
Rated Power (KVA) |
High Voltage (KV) |
Low Voltage (V) |
Dimension(mm) |
Weight(KG) |
|||
W |
D |
H |
Oil Weight |
Total Weight |
|||
5KVA |
24.94/14.4kV 12.47/7.2kV 34.5KV/ 19.92KV/ 13.8KV/ 13.2KV/ or others |
120/240V 480Y/ 277V 600Y/ 347V |
465 |
485 |
855 |
15 |
92 |
10KVA |
500 |
525 |
885 |
22 |
150 |
||
15KVA |
520 |
565 |
905 |
30 |
210 |
||
25KVA |
560 |
590 |
935 |
45 |
258 |
||
37.5KVA |
610 |
625 |
935 |
50 |
340 |
||
50KVA |
635 |
675 |
1035 |
62 |
395 |
||
75KVA |
745 |
840 |
1035 |
88 |
480 |
||
100KVA |
770 |
965 |
1035 |
94 |
530 |
||
167KVA |
795 |
890 |
1035 |
138 |
680 |
||
250KVA |
988 |
1001 |
1035 |
150 |
780 |
||
333KVA |
1012 |
1015 |
1035 |
172 |
850 |
Application scenario: Suitable for small distribution networks without three-phase loads, such as agricultural production, lighting electricity, and railway power supply renovation, which can reduce low-voltage line losses by more than 60%.
Hot Tags: 15kva single phase pole mounted transformer, China 15kva single phase pole mounted transformer manufacturers, suppliers, factory, 12 kV 3 phase pole mounted transformer, distribution transformer for pole mounted power supply, electrical power supply for pole mounted power transformers, pole mounted electrical power distribution network, pole mounted step up transformer, power distribution transformer used on poles