35kv Power Transformer
1.Type: outdoor
2.Ambient temperature:max.temperature:+40℃; min.temperature:-30℃
3.Altitude: 1000m(temperature rise shall be corrected when>1000m
4.Relative humidity:<90%(25℃)
5.Installation place: without corrosive gas and apparent fouling
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 35kv power transformer in China. If you're going to buy customized 35kv power transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
introduction of 35kv power transformer

A 35 kV power transformer is a medium-voltage substation transformer that steps 35 kV transmission/distribution voltage down to 10.5 kV, 6.3 kV or 3.15 kV for regional distribution networks, industrial plants, mines, and renewable-energy collection systems. GNEE supplies both oil-immersed (S11 / SZ11 with on-load or off-circuit tap changing) and dry-type (SCB / SG series) 35 kV transformers covering 630 kVA to 25000 kVA.
Manufactured by GNEE Electric, every 35 kV power transformer is designed with dedicated electromagnetic calculation and verification software, optimized core and coil structures, and superior materials - resulting in compact dimensions, light weight, low losses, low partial discharge and low noise, all verified by complete factory testing to IEC 60076.
Oil-Immersed vs Dry-Type: Choosing Your 35 kV Power Transformer
|
Item |
Oil-Immersed (S11 / SZ11) |
Dry-Type (SCB / SG) |
|
Voltage level |
35 kV and below |
35 kV and below |
|
Typical ratings |
630–25000 kVA |
30–2500 kVA (larger on request) |
|
Cooling |
ONAN / ONAF |
AN / AF |
|
Fire safety |
Requires oil containment; ester fluid optional |
Flame-retardant, no oil |
|
Installation |
Outdoor substations, main transmission and distribution |
Indoor, high-rise, hospitals, data centers, new-energy stations |
|
Maintenance |
Periodic oil sampling and treatment |
Reduced maintenance (cleaning, IR measurement) |
|
First cost |
Lower at large ratings |
Higher; preferred where fire rules apply |
- Oil-immersed 35 kV transformers (S11 / SZ11): high insulation performance and reliability for power transmission and distribution systems, main transmission lines and industrial distribution. SZ11 models add on-load tap changing (OLTC) for automatic voltage regulation.
- Dry-type 35 kV transformers (SCB / SG): fire-resistant, moisture-resistant and maintenance-reduced, widely used in industrial, medical and new-energy applications and in buildings where oil-filled units are not permitted.
Tip: If the load center sits inside a building or near occupied areas, dry-type usually wins despite the higher first cost, because it removes fire compartments, oil containment and ventilation requirements. For outdoor substation duty above ~2500 kVA, oil-immersed is the economical default.
Applications
-
Oil-Immersed Transformers
-
Dry-Type Transformers
35 kV Power Transformer Operating Conditions
- Type: outdoor (indoor available)
- Ambient temperature: maximum +40 °C; minimum −30 °C
- Altitude: ≤ 1000 m (temperature-rise correction required above 1000 m)
- Relative humidity: < 90% (25 °C)
- Installation site: free from corrosive gases and heavy pollution
Note: For altitudes above 1000 m, ambient temperatures below −30 °C, or corrosive/polluted sites (coastal, chemical, mining), the design must be derated or upgraded at order stage - declare site conditions with your inquiry.
35 kV Three-Phase Double-Winding Power Transformer Specifications
35 kV three-phase double-winding transformer series, off-circuit tap changing (on-load regulation available as SZ11). Loss values per GB/T 6451 design basis:
|
Rated Capacity (kVA) |
HV Tapping Range (kV, %) |
LV (kV) |
Vector Group |
No-Load Loss (kW) |
Load Loss (kW) |
No-Load Current (%) |
Short-Circuit Impedance (%) |
|
630 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
0.83 |
7.86 |
0.65 |
6.5 |
|
800 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
0.98 |
9.40 |
0.65 |
6.5 |
|
1000 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
1.15 |
11.5 |
0.65 |
6.5 |
|
1250 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
1.40 |
13.9 |
0.55 |
6.5 |
|
1600 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
1.69 |
16.6 |
0.45 |
6.5 |
|
2000 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
2.17 |
18.3 |
0.45 |
6.5 |
|
2500 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
2.56 |
19.6 |
0.45 |
6.5 |
|
3150 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
3.04 |
23.0 |
0.45 |
7.0 |
|
4000 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
3.61 |
27.3 |
0.45 |
7.0 |
|
5000 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
4.32 |
31.3 |
0.45 |
7.0 |
|
6300 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
Yd11 |
5.24 |
35.0 |
0.45 |
7.0 |
|
8000 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
YNd11 |
7.20 |
38.4 |
0.35 |
8.0 |
|
10000 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
YNd11 |
8.70 |
45.3 |
0.35 |
8.0 |
|
12500 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
YNd11 |
10.0 |
53.8 |
0.30 |
8.0 |
|
16000 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
YNd11 |
12.1 |
65.8 |
0.30 |
8.0 |
|
20000 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
YNd11 |
14.4 |
79.5 |
0.30 |
8.0 |
|
25000 |
35, ±2×2.5% |
3.15 / 6.3 / 10.5 |
YNd11 |
17.0 |
94.0 |
0.25 |
10.0 |
How to Select a 35 kV Power Transformer Model
- Capacity – common ratings: 630, 800, 1000, 1250, 1600, 2000, 2500, 3150, 5000, 6300 kVA and above; select based on projected load with 20–30% growth margin.
- Voltage combination – HV 35 kV standard; LV 10.5 / 6.3 / 3.15 kV per your distribution level.
- Regulation method – off-circuit tap changing (standard) or on-load tap changing (SZ11, OLTC) for networks with frequent voltage fluctuation.
- Model notation – example: S11-20000/35 denotes a 20000 kVA (20 MVA), 35 kV oil-immersed transformer of the S11 loss series.
Tip: For renewable-energy collection systems (solar/wind/energy storage), GNEE offers 35 kV transformers specifically designed for generator-side duty - harmonic-tolerant windings and reversed load-flow design.
Why Choose GNEE electric?
Wide voltage coverage – GNEE produces transformers from 10 kV up to 500 kV, including 35 kV oil-immersed, dry-type, amorphous-alloy and new-energy transformers and prefabricated substations.
International certifications – ISO 9001 / ISO 14001 / ISO 45001 / SA8000 systems; 10 kV and 35 kV distribution transformers and compact substations hold IEC, UL, TÜV, CE, KEMA and GOST certifications.
Advanced production equipment – intelligent laser cutting, CNC punch presses, automatic laminating lines, winding units and welding robots in dedicated oil-type and dry-type workshops.
Global track record – products delivered to 72 countries and regions across Asia, Africa, the Americas, Europe, the Middle East and Oceania.
Full engineering support – electromagnetic calculation verification, drawing review, installation training and 7×24 after-sales response.
Send your rated capacity, voltage ratio, vector group, regulation method and site conditions - GNEE's engineering team will verify the design and reply with a factory-direct quotation, loss data and lead time within 24 hours. Contact GNEE Electric now for your 35 kV power transformer project.
transformer Workshop equipment display













Hot Tags: 35kv power transformer, China 35kv power transformer manufacturers, suppliers, factory, dry type power transformer, transformer breaker, power isolation transformer, transformer discount, high voltage transformer, transformer insurance
You Might Also Like
Send Inquiry