The oil-immersed amorphous alloy transformers is equipped with low coercive force, low loss, good temperature stability, and strong protection for thunder and lighting. With the combination of advanced manufacturing processes and equipment, the amorphous alloy transformer is remoted in communication, test, adjustment, and control by computer. All oil type distribution transformers are qualified by National Mechanical & Industrial Bureau and National Power Company. Our amorphous alloy transformers is widely used in power networks, projects, grid construction, etc.
Amorphous Transformers Parameters:
Rated capacity
(kVA) |
Voltage combinations |
The join group designator
|
No-load loss (W) |
Load loss (W) |
Impedance voltage (%) |
No-load current (W) |
||
high pressure (kV) |
Taps (%) |
Low voltage (kV) |
||||||
30 |
6 6.3 10 10.5 10.5 |
±5% or ±2x2.5 |
0.4 |
Dyn11 or Yyn0 |
80 |
600/630 |
4 |
2.3 |
50 |
100 |
870/910 |
2 |
|||||
63 |
110 |
1040/1090 |
1.9 |
|||||
80 |
130 |
1250/1310 |
1.9 |
|||||
100 |
150 |
1500/1580 |
1.8 |
|||||
125 |
170 |
1800/1890 |
1.7 |
|||||
160 |
200 |
2200/2310 |
1.6 |
|||||
200 |
240 |
2600/2730 |
1.5 |
|||||
250 |
290 |
3050/3200 |
1.4 |
|||||
315 |
340 |
3650/3830 |
1.4 |
|||||
400 |
410 |
4300/4520 |
|
|||||
500 |
480 |
5100/5410 |
1.2 |
|||||
630 |
570 |
6200 |
4.5 |
1.1 |
Application of S(B)H15 series oil-immersed amorphous alloy core transformers
Suitable for high-rise buildings, commercial centers, airports, tunnels, chemical plants, nuclear power plants, ships and other important or special environmental places. At the same time, it also applies to industrial and mining enterprises and power system users with high power supply quality requirements, high environmental requirements and fire prevention requirements.
Product Features of oil-immersed amorphous alloy transformers
With small magnetization power, high resistivity, small eddy current loss, the transformers using vacuum oil injection, can completely eliminate the bubbles in the coil, to ensure the stable insulation performance. Prevent and slow down oil deterioration and insulation moisture, enhance operation reliability, normal operation maintenance free characteristics.
Packaging&Shipping
Hot Tags: oil immersed amorphous transformers, China oil immersed amorphous transformers manufacturers, suppliers, factory, Amorphous core distribution transformers, 75 kva dry type transformer, overhead distribution transformer, 1000 kva pad mounted transformer, small power transformer, solid state distribution transformer
You Might Also Like
Send Inquiry