Product Introduction
1600kVA 10/0.4kv resin cast dry-type transformer is a dry-type transformer, whose main features are low loss, low noise, good heat dissipation, strong overload capacity, strong short-circuit resistance, good thermal stability, high reliability, long service life, small size, light weight, etc.
Performance parameters Rated capacity: 1600KVA Voltage ratio: 10000V/400V Power phases: three-phase Cooling method: dry self-cooling Winding form: three windings Core form: core type Core shape: ladder type External structure: vertical Efficiency: 85%
Reference standards | IEC 60076 |
Capacity | 1600kVA or Customized |
Frequency | 60 / 50Hz |
Voltage (HV) | 11kv or Customized |
Voltage (LV) | 0.4kV or Customized |
Impedance | 4% |
Connections (Vector Group) | Dyn11 |
Tapping Range | + 2 x 2.5% , - 2 x 2.5% |
Core materials | Silicon Steel |
Winding materials | Aluminum or copper |
Lightning Impulse Withstand Voltage | IEC standard |
Application scenarios
This transformer is widely used in local lighting, high-rise buildings, airports, docks, CNC machinery and equipment and other places. Due to its high level of resistance to short circuit and lightning strike, it also has the characteristics of flame retardancy, moisture resistance, dust resistance, and low noise, and is particularly suitable for installation and use in places with high fire protection requirements such as flammable and explosive places.
Transformer loading and unloading and transportation
During the loading and unloading and transportation of transformers, it must be ensured that there is no severe shock and vibration. For transformers with a voltage of 220kV and above and a capacity of 150MV·A and above, a three-dimensional shock recorder should be installed, and the shock value should be ensured to comply with the provisions of the manufacturer and equipment technical documents. In addition, transformers filled with dry gas for transportation must also maintain the gas pressure in the oil tank between 0.01-0.03MPa, the dry gas dew point is lower than -40℃, and the positive pressure is always maintained, and a pressure gauge is set for monitoring.
Hot Tags: 1600kva 11-0.4kv cast resin dry type transformer supplier, China 1600kva 11-0.4kv cast resin dry type transformer supplier manufacturers, suppliers, factory, Three Phase Power Transformer, 1500 kva pad mounted transformer, Dry Type Transformer, Oil Insulated Current Transformers, Three Phase Pad Mounted Transformer, S M Series Oil Immersed Power Transformer