50kVA Dry-Type Winding Non Excited Voltage Regulating Distribution Transformer
Capacity: 50kVA
Delivery Year: 2023
Country: Australia
Key Advantages:
High Efficiency: 15% lower no-load loss compared to traditional Excited Voltage Regulating Distribution Transformers;
Eco-Friendly & Safe: Oil-free dry-type design complies with Australian fire safety standards;
Precision Voltage Regulation: Achieves ±5% voltage stabilization via Winding Non Excited Voltage Regulating technology;
Compact Size: 20% smaller footprint than standard Voltage Regulating Distribution Transformers, saving installation space.
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 50kva dry-type winding non excited voltage regulating distribution transformer in China. If you're going to buy customized 50kva dry-type winding non excited voltage regulating distribution transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
Product Description of Non Excited Voltage Regulating Distribution Transformer
This dry-type transformer utilizes advanced Winding Non Excited Voltage Regulating technology, engineered for commercial and industrial power distribution systems. Its core strength lies in precise voltage control (±5%) through a non-excited regulation module, eliminating frequent power interruptions for adjustments and significantly enhancing supply stability. Unlike Excited Voltage Regulating Distribution Transformers that rely on external excitation devices, this dry-type transformer reduces energy loss by optimizing winding structures. The fully enclosed design (IP54-rated) ensures adaptability to humid or dusty environments. As a Voltage Regulating Distribution Transformer, its epoxy resin casting guarantees superior insulation and eliminates oil leakage risks, making it ideal for safety-critical applications like data centers and hospitals. With a 50kVA capacity and balanced three-phase output, this dry-type transformer efficiently supports small-to-medium grid demands, positioning it as the optimal choice for modern power distribution networks.

Advantages Over Conventional Transformers
① Energy Efficiency & Sustainability
Compared to standard Voltage Regulating Distribution Transformers, this dry-type transformer adopts an oil-free design, reducing environmental hazards and eliminating coolant replacement, cutting maintenance costs by 30%. Its Winding Non Excited Voltage Regulating technology adjusts voltage via physical winding modifications, achieving 18% lower energy conversion loss than Excited Voltage Regulating Distribution Transformers.
② Safety & Adaptability
Traditional oil-immersed transformers pose fire risks, whereas this dry-type transformer features a flame-retardant epoxy-sealed structure (compliant with IEC 60076-11), enabling deployment in basements or high-rises. Its weather resistance surpasses ordinary Voltage Regulating Distribution Transformers, operating reliably from -25°C to +50°C.
③ Precision & Reliability
Standard Excited Voltage Regulating Distribution Transformers depend on electronic excitation systems vulnerable to electromagnetic interference. In contrast, this dry-type transformer employs mechanical non-excited regulation, enhancing anti-interference capability with voltage adjustment response times under 0.5 seconds. Lab tests confirm a 25% longer service life and MTBF (Mean Time Between Failures) exceeding 100,000 hours compared to conventional Voltage Regulating Distribution Transformers.
Products parameter
| Main performance parameters of SC (B) 13 dry-type transformer: | |||||||||
| model | Rated Capacity (KVA) |
Connection Symbol | Voltage combination(KV) | no-load loss(W) | load loss(W) | no-load current(%) | Short circuit resistance(%) | ||
| high pressure | tapping range | low pressure | |||||||
| SC13-30 | 30 | Yyn0 or Dyn11 |
10 6.3 6 |
±5% ±2×2.5% or +1/+3 × 2.5 |
0.4 | 150 | 710 | 2.0 | 4.0 |
| SC13-50 | 50 | 215 | 1000 | 2.0 | |||||
| SC13-80 | 80 | 295 | 1380 | 1.5 | |||||
| SC13-100 | 100 | 320 | 1570 | 1.5 | |||||
| SC13-125 | 125 | 375 | 1850 | 1.3 | |||||
| SC(B)13-160 | 160 | 430 | 2130 | 1.3 | |||||
| SC(B)13-200 | 200 | 495 | 2530 | 1.1 | |||||
| SC(B)13-250 | 250 | 575 | 2760 | 1.1 | |||||
| SC(B)13-315 | 315 | 705 | 3470 | 1.0 | |||||
| SC(B)13-400 | 400 | 785 | 3990 | 1.0 | |||||
| SC(B)13-500 | 500 | 930 | 4880 | 1.0 | |||||
| SC(B)13-630 | 630 | 1070 | 5880 | 0.85 | |||||
| SC(B)13-630 | 630 | 1040 | 5960 | 0.85 | 6.0 | ||||
| SC(B)13-800 | 800 | 1210 | 6960 | 0.85 | |||||
| SC(B)13-1000 | 1000 | 1410 | 8310 | 0.85 | |||||
| SC(B)13-1250 | 1250 | 1670 | 9690 | 0.85 | |||||
| SC(B)13-1600 | 1600 | 1960 | 11700 | 0.85 | |||||
| SC(B)13-2000 | 2000 | 2440 | 14400 | 0.7 | |||||
| SC(B)13-2500 | 2500 | 2880 | 17100 | 0.7 | |||||
Maintenance Guide
① Routine Inspections
Clean the dry-type transformer's surface monthly using dry compressed air (pressure ≤0.3MPa); avoid chemical solvents to prevent epoxy resin corrosion;
Inspect oxidation on Winding Non Excited Voltage Regulating mechanical contacts; apply conductive grease if necessary.
② Environmental Controls
Maintain humidity ≤85% RH in the installation area with adequate ventilation; avoid co-location with Excited Voltage Regulating Distribution Transformers in high-temperature zones;
Monitor winding temperature via infrared thermometers; normal operating temperature rise should be ≤100K (per GB 1094.11).
③ Periodic Maintenance
Test insulation resistance every 6 months using a 2500V megohmmeter (minimum 100MΩ);
Calibrate Winding Non Excited Voltage Regulating tap accuracy annually; return for repair if deviation exceeds ±2%;
Conduct partial discharge tests every 3 years; discharge levels must remain <10pC (IEC 60270 compliant).

Product Testing
This dry-type transformer undergoes four rigorous tests:
Material Inspection: Silicon steel core loss ≤1.30W/kg (B=1.7T, 50Hz); copper winding purity ≥99.99%;
Load Test: 24-hour full-load operation at 50kVA, verifying temperature rise complies with GB/T 22072-2018;
Voltage Regulation Test: Winding Non Excited Voltage Regulating system switches ±5% voltage across 9 taps within ≤1 second;
Comparative Testing: Operates alongside Excited Voltage Regulating Distribution Transformers, achieving 55dB(A-weighted) noise (40% quieter). All data is TÜV Rheinland-certified, ensuring the long-term reliability of this Voltage Regulating Distribution Transformer.
video
Why choose us?
GNEE strictly follows the comprehensive acceptance testing process to ensure that the performance of each device meets the standards. Our products and services have been successfully applied in more than 50 countries and regions around the world. As a trusted global industrial partner, we are always committed to helping customers achieve their sustainable development vision through high-quality products and full-process services.
Support
• Pre-sales: Free technical consulting, drawing review, and installation training.
• After-sales:
o Global warranty for 2 years; 5-year warranty on core components.
o 7×24-hour remote support, fault response within <24 hours.
o Operation manual provided.


Our factory

Packing and Delivery

Hot Tags: 50kva dry-type winding non excited voltage regulating distribution transformer, China 50kva dry-type winding non excited voltage regulating distribution transformer manufacturers, suppliers, factory, 300kVA Power Transformer, indoor dry type transformer, 70kVA Resin Insulation Transformer, SCB18 Transformer, 11KV Dry Type Transformer, Dry Transformers