65kVA Dry Type Isolation Transformer In Trinidad and Tobago

Oct 29, 2025

Leave a message

65kVA Dry Type 3PH Three phase Isolation Transformer In Trinidad and Tobago

Standard: IEC/UNE EN 60076-11

Power Capacity: 65kVA

3 Phase

Input Voltage: 480V

Output Voltage: 208V + N

Frequency: 50/60Hz

Connection Group: Dyn11

Continuous Duty

Cooling: Natural Air

Protection Degree: IP00 – Class I

Winging: Copper Winding H-180 ºC

Magnetic Core: Low Losses

Insulation Class: H-180 ºC

info-693-408

info-723-612

*Full load heat dissipation= 1000 W

 

Dry type transformer is widely used in the places such as hotel, restaurant, airport, power plant, hospital, skyscraper, shopping center, and residential areas and other adverse environments like subways, smelt and power plant, ship, offshore drilling platform, etc.

Technical Data

Model Rated power capacity Voltage Ratio Vector group(connection) Loss (Watt) Voltage Impedance % Dimension(Lx WxH) Net weight(kgs
Rated primary voltage (KV) Tapping range rated secondary voltage (V) No load loss Full load loss
SCB11-30/10 30 KVA 3.3 KV 6.0 KV 6.6 KV 6.3KV 10KV 11KV 13.2KV 13.8KV 15KV 20KV 22KV 24KV 30KV 33KV 35KV 36KV ± 2 X 2.5% 380V , 400 V , 415V 430V 440V etc Dyn11 , Yyn0...etc 171 665 4 680x400x686 300
SCB11-50/10 50 KVA 243 941 690x400x686 360
SCB11-75/10 75 KVA 320 1300 730x450x796 500
SCB11-100/10 100 KVA 360 1492 730x500x816 600
SCB11-125/10 125 KVA 423 1748 780x600x950 700
SCB11-160/10 160 KVA 486 2014 950x650x1124 850
SCB11-200/10 200 KVA 558 2394 990x650x1165 950
SCB11-250/10 250KVA 648 2613 1020x650x1207 1100
SCB11-315/10 315 KVA 792 3287 1050x750x1320 1250
SCB11-400/10 400 KVA 873 3781 1100x800x1450 1550
SCB11-500/10 500 KVA 1044 4636 1140x800x1430 1850
SCB11-630/10 630 KVA 1206 5577 1250x800x1500 1900
SCB11-800/10 800 KVA 1368 6603 6 1330x800x1500 2200
SCB11-1000/10 1000 KVA 1584 7714 1400x960x1640 2750
SCB11-1250/10 1250 KVA 1881 9206 1450x960x1690 3300
SCB11-1600/10 1600 KVA 2205 11144 1560x960x1930 4000
SCB11-2000/10 2000 KVA 2988 13728 1680x960x1930 4800
SCB11-2500/10 2500 KVA 3240 16312 1720x1010x1950 5500

 

 

1.Power Capacity: 30-16000KVA

2.Voltage Level: 6KV, 6.3KV 6.6 KV 10KV 11KV 13.8KV 15KV 20KV 22KV 30KV 33KV 36KV....

3.Type of Voltage Regulation: Off-circuit or On-Ioad

4.Tapping Range: ±5 % ±2x2.5 % ±4x2.5 %

5.Frequency: 50Hz or 60Hz

6.Phases: Three or Single

7.Connection Symbol / Vector Group: Dyn11,Yyn0 ( or as requested)

8.Short- circuit Impedance: Standard Impedance

9.Maxmun Temperature Rise: 100K

10.Insulation & heatproof Class:Class F or H

11.Protection Class:IP00/IP20/IP23/IP40/IP50

12.Altiude is not exceeding 1000m,ambient temperature not exceeding 40ºC. If it can't meet such conditions,we will modulate parameters in accordance with standard

 

Three phase Dry Type Transformer Csae:

SCB10 -1500 KVA-6.6/0.415KV Three phase Dry Type Transformer Shipped To South Africa.

 

Delivered to

South Africa

Year

2022

Model

SCB10 -1500 KVA-6.6/0.415KV

Type

resin cast dry type transformer

Standard

IEC60076

Rated Power

1500 KVA

Frequency

50 HZ

Phase

Three

Cooling Type

AN/AF

Primary Voltage

6.6 KV

Secondary Voltage

0.415 KV

Winding Material

Copper

Vector Group

Dyn11

Impedance

6%

Tap Changer

NLTC

Tapping Range

±2*2.5%

No Load Loss

2.45 KW

On Load Loss

11.73 KW

Accessories

Standard Configuration

1500 KVA-6.6/0.415KV Three Phase Dry Type Transformer

1500 KVA 6.6/0.415KV Transformer Manufacturing Process

1500 KVA 6.6/0.415KV Transformer

Finished 1500 KVA 6.6/0.415KV copper winding dry type transformer

1500 KVA 6.6/0.415KV Copper Winding Dry Type Transformer

1500 KVA 6.6/0.415KV Copper Winding Dry Type Transformer

Send Inquiry