50kVA 10kV Non-Excited Pressure Regulating Oil Immersed Power Transformer

50kVA 10kV Non-Excited Pressure Regulating Oil Immersed Power Transformer

Product Name: 50kVA 10kV Non-Excited Pressure Regulating Oil-Immersed Power Transformer Capacity: 50kVA
Delivery Year: 2020
Country: USA
Key Advantages:
Precise Voltage Regulation Capability: Supports ±5% voltage adjustment without load, adapting to U.S. grid fluctuations and ensuring stable load operation.
High Reliability Design: A fully sealed oil-immersed structure with dust-proof and shock-resistant features, meeting IEEE/NEMA standards for harsh industrial environments.
Energy Efficiency & High Performance: Optimized winding and cooling systems achieve over 98% efficiency, reducing long-term operational energy costs.
Compact Compatibility: Standard dimensions (120×80×150 cm) ensure seamless integration with existing power infrastructure and simplify installation.
Send Inquiry
Chat Now

Have questions? GNEE sales representatives are available for live chat now

Send E-mail: sales@gneeelectric.com

Tel: +8615824687445

Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 50kva 10kv non-excited pressure regulating oil immersed power transformer in China. If you're going to buy customized 50kva 10kv non-excited pressure regulating oil immersed power transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.

 

Products parameter

 

 

6.3kv-15kv Distribution Transformer
Rated capacity kVA HV (KV ) HV tapping range LV (KV) Connection symbol NO-load loss W Load loss W No-load current
%
30 6.3kV
10.5kV
11kV
13.2kV
13.8kV
15kV
±2
× 2.5%;
Or ±5%
0.4 Dyn11 or Yyn0 90 660 2.1
50 130 960 2.0
63 150 1145 1.9
80 180 1370 1.8
100 200 1650 1.6
125 240 1980 1.5
160 290 2420 1.4
200 330 2860 1.3
250 400 3350 1.2
315 480 4010 1.1
400 570 4730 1.0
500 680 5660 1.0
630 810 6820 0.9
800 980 8250 0.8
1000 1150 11330 0.7
1250 1350 13200 0.7
1600 1630 15950 0.6
2000 1950 19140 0.6
2500 2340 22200 0.6
10kv-35kv Distribution Transformer
Rated capacity kVA High Voltage(kv) Low Voltage(kv) Connection symbol No-load loss(w) On-load loss(w) No load current(%)
400 10kv
11kv
20kv
35kv
0.4 Ydn11
Yyn0
570 4300 0.45
500 680 5410 0.45
630 810 30800 0.4
800 980 7500 0.4
1000 1150 10300 0.35
1250 1360 12000 0.3
1600 1640 145000 0.6
2000 1950 19140 0.6
2500 2340 22220 0.5

 

 

Product Introduction Non-Excited Pressure Regulating Power Transformer

 

 

50kVA 10kV Non-Excited Pressure Regulating Oil Immersed Power Transformer


The 50kVA 10kV Non-Excited Pressure Regulating Oil Immersed Power Transformer is a ‌3 Phase Oil-immersed Power Transformer‌ designed for medium- and low-voltage distribution systems, ideal for industrial, commercial, and data center applications. Featuring a ‌fully sealed oil-immersed structure‌, it minimizes leakage risks and enhances operational safety. Its core advantage lies in the integrated ‌Non-Excited Pressure Regulating Power Transformer‌ technology, which stabilizes voltage output during load fluctuations through non-excited pressure adjustment, ensuring consistent power quality.

The ‌Power Transformer‌'s windings utilize high-permeability silicon steel and high-temperature-resistant insulation materials, achieving low no-load losses and high load capacity while complying with international energy efficiency standards. Its compact design reduces footprint requirements, and its IP23 protection rating enables reliable outdoor operation in variable environments. This transformer is a robust choice for upgrading small-to-medium-scale power systems.

 

 

Voltage Regulation Mechanism and Features

 

 


Working Principle‌:
The ‌Non-Excited Pressure Regulating Power Transformer‌ employs a ‌non-excitation tap-changer‌ and a pressure-sensing system for voltage regulation. When grid voltage fluctuates, the pressure sensor detects oil pressure changes and triggers the controller to switch the tap-changer to a preset position, adjusting the winding turns ratio to stabilize output voltage within ±5%. This process is ‌performed in a de-energized state (non-excited)‌, ensuring safe and reliable operation.

 

Key Features‌:

Precision Voltage Regulation‌: Rapid pressure adjustment responds to sudden industrial load changes or grid fluctuations, maintaining stable output in the ‌3 Phase Oil-immersed Power Transformer‌.

Low Maintenance‌: The fully sealed structure and pressure compensation system minimize oil exposure to air, reducing oxidation and moisture ingress, extending the ‌Power Transformer‌'s lifespan to over 25 years.

Energy Efficiency‌: Optimized winding alignment and high-quality insulating oil reduce no-load losses below IEC 60076 standards, significantly cutting operational costs.

Environmental Resilience‌: Tested for operation in temperatures ranging from ‌-30°C to +50°C‌, the ‌Non-Excited Pressure Regulating Power Transformer‌'s tap-changer also features dustproof and waterproof capabilities.

 

50kVA 10kV Non-Excited Pressure Regulating Oil Immersed Power Transformer

 

Contact now

 

 

video

 

 

 

 

Complete Installation Guide Non-Excited Pressure Regulating Power Transformer

 

 


1. Preparations

Ensure the installation site is ‌level and vibration-resistant‌, with adequate space for the Power Transformer (dimensions: 120cm × 80cm × 150cm).

Verify ‌grounding system compliance‌ and prevent metallic dust exposure to the Non-Excited Pressure Regulating Power Transformer's housing.

2. Lifting and Positioning

Use a forklift or crane to hoist the ‌3 Phase Oil-immersed Power Transformer‌ onto the foundation.

Calibrate alignment with a leveling instrument (‌leveling error ≤2°‌) to prevent oil leakage due to uneven oil levels.

3. Wiring and Sealing Inspection

Connect busbars according to the wiring diagram for the ‌high-voltage side (10kV)‌ and ‌low-voltage side (0.4kV)‌.

Tighten bolts to specified torque values using a torque wrench.

Inspect all sealing gaskets and observation windows to ensure no leaks in the oil-immersed environment.

4. Oil Level and Pressure Adjustment

Refill insulating oil through the filling port until the oil gauge reaches the midpoint.

Test system sealing by activating the pressure relief valve.

Recheck oil levels after 24 hours and adjust to the standard range if necessary.

5. System Testing

Insulation resistance test‌ (≥1000MΩ).

Withstand voltage test‌ (1.5x rated voltage without breakdown).

Tap-changer verification‌ (voltage regulation accuracy of ±1%).

Load test‌ (temperature rise/noise levels comply with standards).

 

50kVA 10kV Non-Excited Pressure Regulating Oil Immersed Power Transformer

 

Contact now

 

 

Why choose us?

 

 

50kVA 10kV Non-Excited Pressure Regulating Oil Immersed Power Transformer

 

GNEE strictly follows the comprehensive acceptance testing process to ensure that the performance of each device meets the standards. Our products and services have been successfully applied in more than 50 countries and regions around the world. As a trusted global industrial partner, we are always committed to helping customers achieve their sustainable development vision through high-quality products and full-process services.

 

Support
• Pre-sales: Free technical consulting, drawing review, and installation training.
• After-sales:
Global warranty for 2 years; 5-year warranty on core components.
7×24-hour remote support, fault response within <24 hours.
Operation manual provided.

 

 

Our factory

50kVA 10kV Non-Excited Pressure Regulating Oil Immersed Power Transformer

 

Packing and Delivery

50kVA 10kV Non-Excited Pressure Regulating Oil Immersed Power Transformer

 

 

FAQ
 

Q1: How to Choose Between Oil-Immersed, Dry-Type, or Amorphous Alloy Transformers Based on Needs?

A:Oil-immersed transformers (e.g., 30-2500 kVA/10 kV Oil-Immersed Three-Phase Dual-Winding):
Applicable scenarios: Large factories, substations, outdoor high-voltage power distribution.
Advantages: Excellent heat dissipation for high loads and high-temperature environments, but requires fire prevention and oil leakage precautions.
Dry-type transformers (e.g., Epoxy resin-cast type, Dry-Type Dual-Winding):
Applicable scenarios: Indoor installations (e.g., data centers, commercial buildings), environments with strict fire safety requirements.
Advantages: No insulation oil, pollution-free, low noise, but requires ventilation for heat dissipation.
Amorphous alloy transformers (e.g., Amorphous Alloy Dry-Type):
Applicable scenarios: Grid-end applications, rural power supply, energy-efficient systems.
Advantages: Reduces no-load loss by over 70%, higher efficiency than traditional transformers, ideal for long-term low-load operations.

Q2: Which Equipment is Suitable for Rectifier Transformers (30-3200 kVA Rectifier Type)?

A: Designed specifically for rectifier equipment, such as:
Electroplating lines, electrolytic cells.
Aluminum/copper electrolysis production.
DC motor drive systems.
Features: Three-phase input, adjustable DC voltage output. Note: Harmonic loads may impact transformer performance.

Q3: What are the Differences Between Prefabricated Substations (European Style) and Combined Transformers (Combined Type)?

A:Prefabricated Substations:
High integration: Includes transformers, low-voltage cabinets, and protection devices pre-installed in weatherproof/fire-resistant enclosures.
Applicable scenarios: Rapidly deployable outdoor power systems (e.g., temporary construction sites, remote areas).
Combined Transformers:
Functional integration: Typically combines transformers, metering devices, and protection equipment to simplify power distribution.
Applicable scenarios: Power distribution hubs for small/medium factories or commercial complexes.

Q4: What is the Voltage Adjustment Method for 30-2500 kVA Dual-Winding Non-Adjustable Voltage Transformers?

A:Non-adjustable type: Fixed output voltage set at factory (e.g., 10 kV input → 400 V output); no on-site adjustment.
Applicable scenarios: Stable voltage environments with minimal load fluctuations (e.g., fixed production lines).
For voltage adjustment, choose on-load tap-changing transformers (customizable).

Q5: What are the Temperature Resistance and Lifespan of Epoxy Resin-Cast Dry-Type Transformers?

A:Temperature resistance: Class F (155°C) or Class H (180°C), with overload capacity up to 1.5× rated power.
Lifespan: Over 20 years under normal operation, but requires regular inspections of winding insulation and cooling systems.

 

Contact now

 

 

Hot Tags: 50kva 10kv non-excited pressure regulating oil immersed power transformer, China 50kva 10kv non-excited pressure regulating oil immersed power transformer manufacturers, suppliers, factory, Single Phase Transformer, transformer oil renewal, transformer energy saving, Oil Immersed Distribution Transformer, 4000kV Distribution Transformers, Oil Insulated Current Transformers