S11-160KVA 11KV Oil Immersed Distribution Transformer
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of s11-160kva 11kv oil immersed distribution transformer in China. If you're going to buy customized s11-160kva 11kv oil immersed distribution transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
Product Introduction
S11-160KVA 11KV oil-immersed distribution transformer is a high-quality distribution transformer with the following main features and performance parameters:

| Rated capacity: | 160KVA |
| Rated voltage: | 11KV/0.4KV |
| Cooling method: | Oil-immersed self-cooling |
| Moisture-proof method: | Sealed |
| Winding type: | Double winding |
| Core type: | Core type, the core shape is ladder type |
| External structure: | Vertical |
| Efficiency: | 85% |
| Weight: | About 810kg |
Material and design: The transformer is made of imported high-quality cold-rolled silicon steel sheets. The core design reduces no-load loss and no-load current. At the same time, the core is tied to ensure the compactness of the core, thereby reducing noise.
High and low voltage windings are wound with oxygen-free copper. The low voltage winding 500KVA and below adopts a double-layer cylindrical structure, 630KVA and above adopts a double or quadruple spiral structure, and the high voltage winding adopts a multi-layer cylindrical structure.
Technical parameters: The rated capacity of the S11-160KVA 11KV oil-immersed distribution transformer is 160KVA, the high voltage side voltage is 11KV, and the low voltage side voltage is 0.4KV. Its impedance voltage is 4%, the size is 1250X650X950 mm, and the weight is about 345 kg.
Application scenarios: This transformer is suitable for various occasions that require efficient and stable power supply, especially for large enterprises and public utilities such as power plants and rail transit. Its fully sealed structure design prolongs the service life and eliminates the trouble of hanging the core and maintenance.

Why should the iron core of the transformer be grounded?
When the transformer is in operation, its iron core and other accessories will be in the electric field around the winding. If not grounded, these components may induce a certain voltage. Under the action of the applied voltage, when the induced voltage exceeds the discharge voltage to the ground, a discharge phenomenon will occur, which may damage the transformer. Therefore, in order to prevent internal discharge and ensure the safe operation of the transformer, the iron core must be grounded.
Hot Tags: s11-160kva 11kv oil immersed distribution transformer, China s11-160kva 11kv oil immersed distribution transformer manufacturers, suppliers, factory, 300kVA Oil Filled Transformer, Three Phase Oil Immersed Distribution Transformer, transformer reactive power control, 150kVA Oil Immersed Distribution Transformer, transformer environmental protection, 10kV Transformer
You Might Also Like
S13 Oil Immersed Transformer 800kVA High Quality Fac...
10kv 100kVA Three-phase Oil Immersed Power Transformer
High Quality 80 KVA 11KV Oil Filled Power Distributi...
S13-M Series Three Phase Oil Immersed Distribution T...
Oil Immersed Power Distribution Transformer
10kV-35kV Low Loss Oil Immersed Distribution Transfo...
Send Inquiry