10kVA Single Phase Pole Mounted Distribution Transformer
Phase: Single Phase
Capacity: 10 KVA
Primary BlL: 125 kV
Secondary BlL: 30 KV
Material:Aluminum
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 10kva single phase pole mounted distribution transformer in China. If you're going to buy customized 10kva single phase pole mounted distribution transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
The transformer is cylinder sealing structure. Each one is fixed with grounding devices, hooks, sup porting lugs and one or two high voltage bushing on the cover, low voltage bushing on the wall of the tank and eyebolt,connecting terminals. The tap changer should be adjusted basing on the instruction after the power off.
10kva Overhead Distribution Transformer Main data
| Transformer Type | Overhead Distribution Transformer, Conventional Type |
| Phase | Single Phase |
| Capacity | 10 KVA |
| Primary Voltage | 12470 |
| Primary Voltage Class | 25 kV Class |
| Secondary Voltage | 120/240V (L-N-L) |
| Secondary BIL | 30 KV |
| Frequency | 60 Hz |
| Temperature Rise | 65°C |
| Insulation Rating | Class E Insulation - 120°C, 248°F |
| Cooling Class | KNAN; Self-Cooled |
| Efficiency Standard(s) | Meets DOE 2016 Standards, Meets CSA Standards Meets ANSI/IEEE Standards |
| Winding Material | Copper |
| Ambient Temperature Rating | 40°C |
| Ambient Operating Temperature Range | -40°C to +40°C (-50°F to +104°F) |
| Sound Level | 48 dBA |
| Tank Material | 304 Stainless Steel |
| Ratings | Meets/Exceeds DOE 2016 Efficiency Ratings |
| Efficiency | 98.30% |
| No Load Loss (in watts) | +/- 47W |
| Full Load Loss (in watts) | +/- 156W |
| Total Load Loss (in watts) | +/- 203W |
10kVA Single Phase Pole Mounted Distribution Transformer Drawing

Technical spec for single phase pole mounted transformer
|
Rated Power |
Primary Voltage |
Secondary Voltage |
No load loss (W) |
Load loss (W) |
|
3 KVA |
6KV 6.66KV. 6.35KV 7.2KV 7.6KV 10KV 11KV 13.2KV 13.8KV |
120/240V 240/480V 139/277V 120/208V 600V |
9 |
45 |
|
5 KVA |
19 |
75 |
||
|
10 KVA |
36 |
120 |
||
|
15 KVA |
50 |
195 |
||
|
25 KVA |
80 |
290 |
||
|
37.5 KVA |
105 |
360 |
||
|
50 KVA |
135 |
500 |
||
|
75 KVA |
190 |
650 |
||
|
100 KVA |
210 |
850 |
||
|
167 KVA |
350 |
1410 |
10kva Pole Mount Overhead Transformer Accessories
| MT-UPM-R7-1P-GMF-10KVA-SZ-BB-A6-BM-AZ-Z-M1 Pole Mount Overhead Transformer |
| Transformer Type: Overhead Distribution Transformer, Conventional Type |
| Transformer Configuration: Liquid Filled Pole Mounted |
| Transformer Polarity Type: Subtractive |
| Phase: Single Phase |
| Capacity: 10 KVA |
| Primary Voltage: 24940GrdY/14400 Grounded Wye (2 Wire) |
| Primary Voltage Switch: N/A |
| Primary Voltage Class: 25 kV Class |
| Primary Phasor: Grounded Wye |
| Primary BIL: 125 kV |
| Secondary Voltage: 120/240V (L-N-L) |
| Secondary Voltage Class: 1.2 kV Class |
| Secondary Phasor: Dual Winding Single Phase |
| Secondary BIL: 30 KV |
| Frequency: 60 Hz |
| Temperature Rise: 65°C |
| Insulation Rating: Class E Insulation - 120°C, 248°F |
| Forced Air (Fans): None |
| Cooling Class: ONAN; Self-Cooled |
| Tap Changer: 5-Position Tap Changer w/ External Operating Handle |
| Tap Qty: (2) FCAN Above, (2) FCBN Below |
| Tap %: 2.5% |
| Tap Changer Switch Location: Middle of Tank Body, Left of Mounting Provisions |
| Impedance: 1.0-4.5% Typical |
| Primary Connection Type: Live Bushing Lug |
| Primary Termination: Porcelain High Voltage Bushing |
| Primary Connection Qty: (2) |
| Primary Lightning Arrestors: N/A |
| Primary Lightning Mounting Provision: Mounting Provisions for Installing Lightning Arrestor on H1 & H2 Primary Terminals |
| Primary Lightning Arrestors Voltage Rating: N/A |
| Primary Lightning Arrestors MCOV Rating: N/A |
| Secondary Connection Type: Live Bushing Lug |
| Secondary Connections: Threaded Stud Terminals |
| Secondary Connection Qty: (3) |
| Secondary Neutral Connection: Secondary X2 Neutral Grounded to Tank via 1/2"-13 UNC Tapped Hole, 7/16" Deep Bung & Copper Ground Strap |
| Terminals: Tin Plated Primary and Secondary - Accepts Copper or Aluminum Connections |
| Grounding Provisions: (1) Lug w/ Grounding Strap, Tank Grounding Lug |
| Transformer Protection: N/A |
| Load Break Switch: N/A |
| Efficiency Standard(s): Meets DOE 2016 Standards, Meets ANSI/IEEE Standards |
| K-Factor Rating (Harmonic Mitigation): K-1 (Standard) |
| Pulse Drive Rating: N/A |
| Insulation Fluid: Mineral Oil - Non PCB Fluid |
| Fluid Capacity*: 5.38 Gallons |
| Fluid Weight*: 48.5 lb |
| Liquid Level Indicator: Internal In-Tank Oil Level Line |
| Temperature Indicator: N/A |
| Pressure/Vacuum Indicator: N/A |
| Pressure Relief Device: Included, Automatic Action |
| Fault Indicator: N/A |
| Oil Level Marking: Internal |
| Fill Valve: N/A (Tank Filled via Removable Lid) |
| Drain Valve: 1/2" NPT Port w/ Removable Bolt |
| Winding Material: Aluminum |
| Ambient Temperature Rating: 40°C |
| Sound Level: 48 dBA |
| Elevation Level: N/A |
| Core Material: Grain Oriented Steel |
| Tank Material: Coated Steel |
| Housing Material: Coated Steel w/ Corrosion Resistant Cover Band, Removable Top Cover |
| Hardware Material: Stainless Steel Hardware |
| Paint Type: Weatherproof and UV Resistant Epoxy Coating and Undercoating |
| Finish Color: White |
| Mounting: Double Hanger Bracket |
| Mounting: Pole Mount via Hangar Brackets |
| Lifting Lugs: Included |
| Dimensions*: 18.5''-W x 21.65''-D x 35.83''-H |
| Tank Diameter*: 13.39'' OD |
| Dry Weight*: 99.21 lb |
| Total Weight (Liquid Filled)*: 217 lb |
Products parameter of Pole Mount Transformer
| Power (KVA) |
Input Voltage (V) |
Output Voltage (V) |
Loss(W) | Dimension (mm) | Weight (kg) |
|||
| No-load Loss | On-load Loss |
W | D | H | ||||
| 5 | 34500/ 19920/ 13800/ 7957 13200/ 7620 12470/ 7200 or others |
120-240 240-480 347-600 |
19 | 75 | 465 | 485 | 855 | 92 |
| 10 | 36 | 120 | 500 | 525 | 885 | 150 | ||
| 15 | 50 | 195 | 520 | 565 | 905 | 210 | ||
| 25 | 80 | 290 | 560 | 590 | 935 | 258 | ||
| 37.5 | 105 | 360 | 610 | 625 | 935 | 340 | ||
| 50 | 135 | 500 | 635 | 675 | 1035 | 395 | ||
| 75 | 190 | 650 | 745 | 840 | 1035 | 480 | ||
| 100 | 210 | 850 | 770 | 965 | 1135 | 530 | ||
| 167 | 350 | 1410 | 795 | 890 | 1335 | 680 | ||
Product Features of 10kVA pole distribution transformer
This 10kVA pole distribution transformer features a cold-rolled silicon steel core, reducing no-load loss by 30%. Its Pole Mounted Distribution Transformer structure integrates lightning protection devices and fully sealed oil tanks for harsh outdoor environments. As a single phase pole mounted transformer, key attributes include:
Real-time temperature monitoring with overload alerts
Detachable high-voltage bushings for easy maintenance
Ultra-quiet operation (<45dB noise level)
Short-circuit withstand certification (IEC 60076-5)
Renewable energy compatibility (solar/wind power interfaces)
The Pole Mounted Distribution Transformer frame withstands 150km/h wind speeds, while the single phase pole mounted transformer modular design enables rapid component replacement, minimizing power outage durations. Enhanced safety features include bird guards and tamper-proof bolts, meeting IEEE C57.12.28 standards.

Working Principle Pole Mount Transformer
The pole distribution transformer operates via electromagnetic induction: 11kV input current generates alternating flux in the laminated core, inducing 400V output in secondary windings. The Pole Mounted Distribution Transformer utilizes step-lap joint cores to minimize eddy currents, complemented by oil-immersed cooling for thermal stability. As a single phase pole mounted transformer, it features:
Automatic pressure relief valves for overload protection
Off-circuit tap changers (±5% voltage adjustment)
Dielectric oil serving dual cooling/insulation functions (IEC 60296 compliant)
Magnetic flux distribution is optimized through precision wound copper coils, achieving 98.5% efficiency. The Pole Mounted Distribution Transformer design ensures leak-proof performance across -30°C to +55°C environments, while the single phase pole mounted transformer bushings provide creepage distance compliance with IEC 61482.


Why choose us?
GNEE Group:
Global Transformer Supply Chain Integration Expert (2008 - Present)
Founded in 2008, GNEE Group has undergone fifteen years of deep industry cultivation, successfully transforming from a regional trader to a global supply chain management expert. As a pioneer in the integration of the steel industry chain, the group has established a full-cycle value system that spans raw material procurement, production coordination, logistics optimization, and terminal services, setting an innovative operational benchmark in the global transformer distribution sector. In the era of Industry 4.0, GNEE Group is accelerating towards its goal of becoming a global integrator oftransformer industry value through digital restructuring and green supply chain construction.
SGS certification certificate

Packing and Delivery

Our factory

Hot Tags: 10kva single phase pole mounted distribution transformer, China 10kva single phase pole mounted distribution transformer manufacturers, suppliers, factory, transformer for power distribution on poles, voltage transformation around pole mounted transformers, pole mounted step up voltage transformer, pole mounted three phase transformer, 11 kVA 415V Pole Mounted Current Transformer, power transformer used on pole mounted power supply
You Might Also Like
Send Inquiry