PVC Insulated Unarmoured Power Cable

PVC Insulated Unarmoured Power Cable

Product Type:LV Power Cable
Rated Voltage:0.6/1kV
Conductor:Copper (Class 2)
Insulation:PVC
Sheath:PVC
Armouring:Unarmoured
Send Inquiry
Chat Now

Have questions? GNEE sales representatives are available for live chat now

Send E-mail: sales@gneeelectric.com

Tel: +8615824687445

Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of pvc insulated unarmoured power cable in China. If you're going to buy customized pvc insulated unarmoured power cable made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.

 

Our PVC insulated unarmoured power cable is a high-performance low-voltage power distribution solution designed for fixed installations in electrical systems up to 0.6/1kV. Manufactured with premium copper conductors, PVC insulation, and a PVC outer sheath, this PVC insulated PVC sheathed power cable delivers reliable electrical performance combined with excellent mechanical protection for general-purpose applications.

 

PVC Insulated Unarmoured Power Cable

Key Product Highlights

  • Rated Voltage: 0.6/1kV (U₀/U) for low-voltage power distribution
  • Conductor: 99.9% pure annealed copper, Class 2 stranded (IEC 60228)
  • Insulation: High-grade PVC (PVC type A/B/C per IEC 60502-1)
  • Sheath: Extruded PVC outer sheath (ST1/ST2 type)
  • Armouring: Unarmoured - lightweight and cost-effective
  • Operating Temperature: Max. 70°C continuous; 160°C short circuit (≤5s)
  • Standards: IEC 60502-1, IEC 60228, BS 6004, BS 6346

Whether you need a copper conductor PVC cable for urban distribution networks, industrial plants, or commercial buildings, our 0.6/1kV low voltage PVC power cable offers consistent quality, competitive pricing, and reliable delivery. Available in single-core, multi-core (2–5 cores), and 3+1, 3+2, 4+1 configurations to meet every project requirement.

💡 Looking for a specific size or custom specification? We supply PVC insulated power cable from 1.5mm² to 630mm² with 1–61 cores. Tell us your requirements

→ Get a customized quote within 24 hours.

Why Choose Our PVC Insulated PVC Sheathed Power Cable

 

We deliver PVC sheathed unarmoured power cables that combine superior materials, precision engineering, and rigorous quality control. Here's what sets our products apart:

PVC Insulated PVC Sheathed Power Cable

IEC & BS Certified Quality

Full compliance with IEC 60502-1 and BS standards ensures our PVC insulated LV power cable meets global electrical safety and performance requirements.

PVC Insulated PVC Sheathed Power Cable

99.9% Pure Copper Conductor

High-purity annealed copper ensures low resistance, excellent conductivity, and reliable power transmission - reducing energy loss and operating costs.

PVC Insulated PVC Sheathed Power Cable

Premium PVC Insulation & Sheath

Grade-A PVC insulation and sheath provide excellent dielectric strength, moisture resistance, and abrasion protection for long service life.

PVC Insulated PVC Sheathed Power Cable

Wide Range of Sizes

From 1.5mm² to 630mm² with 1 to 61 cores, our unarmoured power cable covers every low-voltage application from residential to industrial projects.

Technical Specifications of 0.6/1kV PVC Unarmoured Power Cable

 

Our IEC BS standard PVC insulated LV power cable is manufactured to the highest precision. Below are the detailed technical parameters for each core configuration. All values comply with IEC 60502-1 and relevant BS standards.

 

Single Core

Nominal Cross Section (mm²) Conductor Diameter (mm) Insulation Thickness (mm) Sheath Thickness (mm) Overall Diameter (mm) Approx. Weight (kg/km)
1×4 2.6 1.0 1.4 7.5 95
1×6 3.1 1.0 1.4 8.0 120
1×10 4.0 1.0 1.4 9.0 165
1×16 5.0 1.0 1.4 10.0 230
1×25 6.3 1.2 1.4 12.0 340
1×35 7.4 1.2 1.4 13.0 450
1×50 8.8 1.4 1.4 14.5 570
1×70 10.6 1.4 1.4 16.0 800
1×95 12.4 1.6 1.5 18.5 1070
1×120 14.0 1.6 1.5 20.0 1300
1×150 15.5 1.8 1.6 22.0 1600
1×185 17.4 2.0 1.7 24.0 1980
1×240 20.3 2.2 1.7 27.0 2560
1×300 22.7 2.4 1.8 30.0 3180
1×400 25.4 2.6 1.9 33.0 4060
1×500 28.8 2.8 2.0 37.0 5140
1×630 30.4 2.8 2.2 42.0

6600

 

Two Cores

Nominal Cross Section (mm²) Conductor Diameter (mm) Insulation Thickness (mm) Sheath Thickness (mm) Overall Diameter (mm) Approx. Weight (kg/km)
2×1.5 1.6 0.8 1.8 12.0 205
2×2.5 2.0 0.8 1.8 13.0 250
2×4 2.6 1.0 1.8 15.0 330
2×6 3.1 1.0 1.8 16.0 400
2×10 4.0 1.0 1.8 17.5 525
2×16 5.0 1.0 1.8 20.0 720
2×25 6.3 1.2 1.8 23.5 1030
2×35 7.4 1.2 1.8 25.5 1320
2×50 8.8 1.4 1.8 28.5 1670
2×70 10.6 1.4 1.8 32.0 2290
2×95 12.4 1.6 1.9 37.0 3060
2×120 14.0 1.6 2.0 40.0 3700
2×150 15.5 1.8 2.2 44.0 4500
2×185 17.4 2.0 2.3 48.0 5570
2×240 20.3 2.2 2.5 55.0 7180

 

Three Cores

Nominal Cross Section (mm²) Conductor Diameter (mm) Insulation Thickness (mm) Sheath Thickness (mm) Overall Diameter (mm) Approx. Weight (kg/km)
3×1.5 1.6 0.8 1.8 13.0 230
3×2.5 2.0 0.8 1.8 13.5 280
3×4 2.6 1.0 1.8 15.5 380
3×6 3.1 1.0 1.8 17.0 470
3×10 4.0 1.0 1.8 18.5 630
3×16 5.0 1.0 1.8 21.0 880
3×25 6.3 1.2 1.8 24.5 1280
3×35 7.4 1.2 1.8 27.0 1660
3×50 8.8 1.4 1.8 30.0 2110
3×70 10.6 1.4 1.9 35.0 2980
3×95 12.4 1.6 2.0 40.0 3930
3×120 14.0 1.6 2.1 43.0 4780
3×150 15.5 1.8 2.3 48.0 5880
3×185 17.4 2.0 2.4 52.0 7230
3×240 20.3 2.2 2.6 59.0 9390
3×300 22.7 2.4 2.7 65.0 11620

 

3+1 Cores

Cross Section (mm²) Cond. Dia. (3C) (mm) Cond. Dia. (1C) (mm) Insul. Thick. (3C) (mm) Insul. Thick. (1C) (mm) Sheath Thick. (mm) Overall Dia. (mm) Weight (kg/km)
3×16/10 5.0 4.0 1.0 1.0 1.8 22.0 1000
3×25/16 6.3 5.0 1.2 1.0 1.8 26.0 1460
3×35/16 7.4 5.0 1.2 1.0 1.8 28.0 1830
3×50/25 8.8 6.3 1.4 1.2 1.8 32.0 2410
3×70/35 10.6 7.4 1.4 1.2 1.9 36.0 3360
3×95/50 12.4 8.8 1.6 1.4 2.1 41.0 4440
3×120/70 14.0 10.6 1.6 1.4 2.2 46.0 5580
3×150/70 15.5 10.6 1.4 1.2 2.3 49.0 6580
3×185/95 17.4 12.4 1.6 1.4 2.5 54.0 8200
3×240/120 20.3 14.0 1.6 1.4 2.6 61.0 10570

 

Four Cores

Nominal Cross Section (mm²) Conductor Diameter (mm) Insulation Thickness (mm) Sheath Thickness (mm) Overall Diameter (mm) Approx. Weight (kg/km)
4×70 10.6 1.4 2.0 38.0 3760
4×95 12.4 1.6 2.1 44.0 4960
4×120 14.0 1.6 2.3 48.0 6110
4×150 15.5 1.8 2.4 53.0 7450
4×185 17.4 2.0 2.6 58.0 9220
4×240 20.3 2.2 2.8 65.0 11900
4×300 22.7 2.4 3.0 72.0 14730

Multi-Core

Configuration Conductor Diameter (mm) Insulation Thickness (mm) Sheath Thickness (mm) Overall Diameter (mm) Approx. Weight (kg/km)
5×1.5 1.6 0.8 1.8 14.5 300
7×1.5 1.6 0.8 1.8 15.5 360
10×1.5 1.6 0.8 1.8 19.0 460
12×1.5 1.6 0.8 1.8 19.5 510
19×1.5 1.6 0.8 1.8 22.0 710
24×1.5 1.6 0.8 1.8 25.0 870
30×1.5 1.6 0.8 1.8 26.0 1020
5×2.5 2.0 0.8 1.8 16.0 375
7×2.5 2.0 0.8 1.8 17.0 460
10×2.5 2.0 0.8 1.8 20.0 590
12×2.5 2.0 0.8 1.8 21.0 660
19×2.5 2.0 0.8 1.8 24.0 940
24×2.5 2.0 0.8 1.8 27.0 1150
30×2.5 2.0 0.8 1.8 29.0 1370

* Note: Specifications shown above are for reference only. Custom configurations including aluminum conductor, flame retardant (FR), low smoke zero halogen (LSZH), and other special requirements are available.

🔍 Can't find the exact specification you need?

We manufacture custom PVC sheathed unarmoured power cables with special sizes, core configurations, and materials.

Contact our engineers for a tailored solution →

 

 PVC Insulated Unarmoured Power Cable

Applications of PVC Insulated Unarmoured Power Cable

 

Our PVC insulated unarmoured power cable is designed for fixed installations in low-voltage electrical systems where mechanical damage risk is minimal. With its versatile PVC/PVC construction, this 0.6/1kV low voltage PVC power cable serves a wide range of applications across residential, commercial, and industrial sectors:

Applications Of PVC Insulated Unarmoured Power Cable
  • Indoor Installations:Building wiring, distribution panels, switchgear rooms, and indoor cable trays
  • Cable Ducts & Trays:Installation in cable ducts, conduits, and ladder racks in industrial and commercial buildings
  • Underground Burial:Direct burial underground in stable soil conditions where mechanical damage risk is low
  • Industrial Plants:Power distribution in factories, manufacturing facilities, and process plants
  • Power Stations:LV distribution in power stations, switchyards, and electrical substations
  • Urban Distribution:Local energy distribution networks and municipal power supply systems
  • Commercial Buildings:Office buildings, shopping malls, hospitals, schools, and high-rise structures
  • Outdoor Installations:Outdoor applications with appropriate UV-stabilized PVC sheath options available

Ready to Source Premium PVC Insulated Unarmoured Power Cable?

Get a free, no-obligation quote within 24 hours. Factory-direct pricing, IEC & BS certified quality, worldwide shipping.

Get Free Quote Now

PVC Insulated Unarmoured Power Cable

fAQ

 

What is the difference between armoured and unarmoured PVC power cable?

An unarmoured power cable (also called non-armoured cable) has no metallic armour layer between the insulation and outer sheath. It consists of conductors, PVC insulation, fillers, and a PVC outer sheath only. Armoured cables have an additional steel wire (SWA) or steel tape (STA) armour layer for mechanical protection. Unarmoured cables are lighter, more flexible, and more cost-effective - ideal for installations in cable ducts, trays, or underground where mechanical damage risk is low. Armoured cables are used for direct burial in rocky soil or areas with higher mechanical stress.

 

What does VV cable mean? Is it the same as PVC insulated PVC sheathed power cable?

Yes, "VV cable" is the standard model designation for PVC insulated PVC sheathed power cable in Chinese GB/T 12706 and IEC standards. The first "V" stands for PVC insulation, and the second "V" stands for PVC sheath. VV cable = copper conductor + PVC insulation + PVC sheath + unarmoured construction. This is exactly equivalent to our PVC insulated unarmoured power cable. The aluminum conductor version is designated VLV (the "L" stands for aluminum).

 

What is the maximum operating temperature of PVC insulated power cable?

Our 0.6/1kV low voltage PVC power cable has a maximum continuous operating temperature of 70°C for the conductor. The short-circuit temperature (for durations up to 5 seconds) is 160°C for conductor sizes ≤300mm² and 140°C for sizes >300mm². The minimum installation temperature is -15°C for standard PVC. For higher temperature requirements, we also offer XLPE-insulated cables (90°C continuous) and heat-resistant PVC options.

 

Do you offer flame retardant PVC insulated unarmoured power cables?

Yes, we offer flame retardant (FR) options for our PVC sheathed unarmoured power cables. Flame retardant grades include FR-PVC (flame retardant PVC), LSZH (Low Smoke Zero Halogen), and fire-resistant options. These comply with IEC 60332-1 (single cable vertical flame test), IEC 60332-3 (bundled cable flame test categories A/B/C), IEC 60754 (halogen content), and IEC 61034 (smoke density).

 

Hot Tags: pvc insulated unarmoured power cable, China pvc insulated unarmoured power cable manufacturers, suppliers, factory

Previous:No Information

Send Inquiry