Primary Voltage Ratings: 10kv
Secondary Voltage Ratings: 0.4kv
H.V. TAP RANGE: ±2×2.5%
CONNECTION TYPE: Dyn11
Send Inquiry
Chat Now

Have questions? GNEE sales representatives are available for live chat now

Send E-mail: sales@gneeelectric.com

Tel: +8615824687445

Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 10kv oil immersed distribution transformers in China. If you're going to buy customized 10kv oil immersed distribution transformers made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.

 

The 10kV oil immersed distribution transformer is a three-phase, mineral-oil-filled transformer that steps 10 kV (or 11 kV) distribution voltage down to 0.4 kV low voltage for factories, mines, petrochemical plants, agricultural networks and utility distribution substations. It is available in two construction types - hermetically sealed (sealed tank, no conservator) and conservator type (with an expansion tank) - both cooled by natural oil circulation and natural air (ONAN).

 

Manufactured by GNEE Electric to IEC 60076, the 10kV oil immersed distribution transformer combines a compact structure, low noise, low losses and strong overload capability, and is suited to demanding sites including locations exposed to oil contamination and chemical substances. Request a factory-direct quotation with complete test reports.

 

What Is a 10kV Oil Immersed Distribution Transformer?

 

A 10kV oil immersed distribution transformer uses insulating oil as both the dielectric medium and the coolant. Compared with dry-type units at the same rating, it offers lower first cost, higher overload tolerance and better suitability for outdoor and harsh-environment installation:

  • Compact structure, small footprint – the sealed tank design integrates core, windings, oil and protection devices in one enclosure with a clean appearance.
  • Low noise and low loss – high-permeability silicon-steel core keeps no-load loss and audible noise low, reducing lifetime operating cost.
  • Strong overload capability – the large thermal inertia of the oil allows short-time overload operation beyond dry-type limits.
  • Harsh-site adaptability – proven performance in industrial and mining environments, including sites with oil contamination and chemical substances.
  • Two construction options – hermetically sealed type (maintenance-reduced, no oil conservator) or conservator type (easier oil sampling and treatment).

Tip: Choose the hermetically sealed type for low-maintenance, lightly loaded distribution duty; choose the conservator type when frequent oil sampling, dissolved-gas analysis or on-site oil treatment is expected over the service life.

3 phase distribution transformer

10kV Oil Immersed Distribution Transformer Specifications

 

Reference model (as listed by the factory):

Parameter

Specification

Model

S11-112/11-0.4 (see Note below on rating notation)

Type

Oil immersed distribution transformer

Standard

IEC 60076

Rated Power

112 kVA (custom ratings from 30 to 2500 kVA)

Phase

Three phase

Frequency

50 Hz (60 Hz available)

Cooling Type

ONAN (Oil Natural, Air Natural)

Primary Voltage

10 kV (11 kV optional)

Secondary Voltage

0.4 kV (0.415 kV optional)

Winding Material

Copper (aluminum optional)

Vector Group

Dyn11 (Yyn0, Yzn11 optional)

Short-Circuit Impedance

4.0–4.5%

Tap Changer

Off-circuit tap changer (NLTC)

Tapping Range

±2×2.5% (±5% optional)

No-Load Loss

0.24 kW

Load Loss

1.80 kW

Accessories

Standard configuration; custom accessories on request

 

Tip: Full S11 series loss tables (30–2500 kVA), outline drawings and dimension sheets are available on request - specify your rated capacity, voltage ratio and vector group when inquiring.

 

Oil immersed distribution transformer Working Environment

 

Correct installation conditions protect performance and service life:

  • Installation altitude: no more than 1000 m above sea level (derating and temperature-rise correction required above 1000 m).
  • Supply voltage waveform: approximately sinusoidal.
  • Supply voltage symmetry: the three-phase supply voltage should be approximately symmetrical.
  • Ambient temperature: maximum +40 °C; maximum daily average +30 °C; maximum annual average +20 °C; minimum −30 °C (outdoor units; indoor units −5 °C unless specified).
  • Relative humidity: ≤ 90% (25 °C) recommended for outdoor installations.

 

Note: For sites above 1000 m altitude or below −30°C, special design measures (enlarged cooling surface; low-temperature insulating oil such as #45 oil; or reduced capacity rating) are required-state the site conditions in your inquiry.

 

Core Features of the S11 Oil Immersed Distribution Transformer

 

  • High-quality core – high-permeability cold-rolled grain-oriented silicon steel, step-lap core construction for reduced no-load loss and noise.
  • Copper windings – high-purity copper conductors with robust insulation withstand short-circuit forces and lightning impulses.
  • Sealed or conservator tank – full-seal design prevents oil oxidation and moisture ingress; conservator design allows oil expansion and convenient maintenance.
  • Complete protection options – gas relay, oil temperature indicator, pressure relief device and on-load monitoring per rating and customer specification.
  • Type-tested and routine-tested – each transformer passes routine tests per IEC 60076 before dispatch; type-test reports are available.

 

Applications of 10kV Distribution Transformers

 

Typical installations for this transformer family:

  • Utility MV/LV distribution substations (10 kV / 0.4 kV)
  • Industrial plants and mining power distribution systems
  • Petrochemical and chemical processing facilities
  • Agricultural irrigation and rural grid networks
  • Commercial buildings and infrastructure projects
  • Renewable energy collection systems (solar and wind farm auxiliary supply)

 

Tip: For petrochemical and chemical sites, confirm the fire-safety and containment requirements of the end user - options include high fire-point ester fluid and oil containment pits, which must be specified before production.

 

Why Choose GNEE as Your Distribution Transformer Manufacturer

 

  • Direct factory – Henan GNEE Electric Co., Ltd. manufactures and exports oil immersed distribution transformers worldwide, with competitive factory-direct pricing.
  • IEC-compliant production – 10 kV and 35 kV distribution transformers hold IEC certification, with ISO 9001 / ISO 14001 / ISO 45001 system certification.
  • Full documentation – routine test reports, outline drawings and operation manuals supplied with every unit.
  • Custom engineering – voltage ratio, vector group, losses, accessories and enclosure tailored to project specifications.
  • Export experience – products delivered to more than 50 countries and regions.

 

Tell us your rated capacity, voltage ratio, vector group and site conditions - GNEE's engineering team will confirm the technical solution and send a factory-direct quotation with lead time within 24 hours. Contact GNEE Electric now for your 10kV oil immersed distribution transformer project.

Request A Quote

 

Installation case

 

Single phase distribution transformer

 

Packaging&Shipping

Transformer and distribution

Hot Tags: 10kv oil immersed distribution transformers, China 10kv oil immersed distribution transformers manufacturers, suppliers, factory, residential distribution transformer, capacity of distribution transformer, pad-mounted distribution transformer, durable distribution transformer, microgrid connection of distribution transformer, cost of distribution transformer

Send Inquiry