500 KVA 33 KV 3 Phase Step Down Distribution Transformer
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 500 kva 33 kv 3 phase step down distribution transformer in China. If you're going to buy customized 500 kva 33 kv 3 phase step down distribution transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
500 KVA 33 KV step-down distribution transformers need to pay attention to the following points when using them:
distribution transformers 'Load current and operating voltage inspection: Ensure that the load current and operating voltage of the oil-immersed transformer are within the normal range to avoid damage to the equipment caused by overload and voltage fluctuations
Oil level and oil temperature inspection: Regularly check the oil level, oil color and temperature of the distribution transformer. The upper oil temperature of oil-immersed self-cooling transformers should be kept below 85℃, and that of oil-enhanced air-cooling and oil-enhanced water-cooling transformers should be kept below 75℃.
Inspection of porcelain bushings: Check whether the high and low voltage porcelain bushings are clean, whether there are cracks, damage and flashover discharge marks, and ensure good insulation performance.
Inspection of wiring terminals: Check whether the wiring terminals have poor contact or overheating, ensure that the connection is firm, and avoid overheating problems caused by poor contact.

| Rated capacity: | 500 kVA |
| Tap position: | High voltage tap voltage (V) |
| Rated voltage: | 10.5/0.3 11000 V |
| Rated frequency: | 50 Hz |
| Connection group number: | DYn11 |
| No-load loss: | 680 W, +15% allowed |
| No-load current: | 1.0 A |
| Load loss: | 5150 W, +10% allowed |
| Short-circuit impedance: | 4% |
Inspection of operating sound: The 33kv step-down oil-immersed distribution transformer should have uniform electromagnetic sound during normal operation. If there is uneven sound or abnormal noise, it may be a sign of loose or damaged internal components.
Inspection of cooling system: Ensure that 500 KVA 33 KV The cooling system of the step-down distribution transformer operates normally, the temperature of the heat dissipation pipe is uniform, and there is no oil pipe blockage.
Inspection of explosion-proof pipes and desiccant: Check whether the explosion-proof pipe diaphragm of the distribution transformer is intact and whether the desiccant is saturated to ensure that the equipment can safely release pressure under abnormal conditions.
Environmental safety inspection: Ensure that the surrounding environment of the oil-immersed distribution transformer is safe before operation, remove flammable materials and fire sources, and avoid welding or cutting around the transformer.

Inspection of insulating oil: Regularly check the insulating performance of the insulating oil, replace the aged or seriously contaminated insulating oil in time, and ensure that its insulating performance meets the requirements.
Regular maintenance: Including cleaning the surface of the transformer, checking the tightness of the terminal, maintaining the cooling system, etc., to ensure that the equipment is in good condition.
Hot Tags: 500 kva 33 kv 3 phase step down distribution transformer, China 500 kva 33 kv 3 phase step down distribution transformer manufacturers, suppliers, factory, distribution transformer for solar power, step down distribution transformer, magnetic field of distribution transformer, buy distribution transformer, single-phase distribution transformer, durable distribution transformer