SC(B) Dry Type Isolation Transformer

SC(B) Dry Type Isolation Transformer

Model: SC(B)
Capacity: 30kVA to 2500kVA (customizable)
Voltage: 10KV 20KV 35KV
Frequency: 50/60Hz
Type: Dry-type (Cast Resin Isolation Dry Type Transformer)
Certifications: ISO 9001, SGS
Key Advantages: Epoxidized resin casting technology ensures high insulation and electrical isolation, with anti-short-circuit and corrosion-resistant features, meeting stringent requirements for fire-resistant environments.
Send Inquiry
Chat Now

Have questions? GNEE sales representatives are available for live chat now

Send E-mail: sales@gneeelectric.com

Tel: +8615824687445

Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of sc(b) dry type isolation transformer in China. If you're going to buy customized sc(b) dry type isolation transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.

 

 

Product Basic Introduction of Dry Type Isolation Transformer

‌

Dry Type Isolation Transformer

 

The SC(B) Dry Type Isolation Transformer is a 3 phase dry type transformer specifically designed for fireproof and high-safety applications. Its core advantage lies in the epoxy resin casting (Cast Resin) technology, which fully isolates primary and secondary circuits to prevent direct current conduction, significantly reducing short-circuit risks. It features low losses (no-load loss ≤0.6%), broad frequency compatibility (50/60Hz switching), and strong harmonic resistance, ensuring stable operation in fluctuating power grids. Its open散热 structure combined with dry-type insulation materials guarantees reliable performance in high-temperature, high-humidity, or corrosive environments, making it ideal for industrial plants, semiconductor factories, and power plants.

 

 

 

Products parameter

 

SC(B)10-100~2500/10 Dry-type Isolation Transformer

Rated Voltage: 10(10.5,11,6.6,6.3,6) kV

Connection Group: Dyn11 or Yyn0

Rated Low Voltage: 0.4 kV

Tap Range: ±2×2.5% and so on

Product Model UK% No-load loss P0 (W) Negative Loss (75°C) Pk(W) I0(%) LPA(AN)dB Gauge m×n Overall dimensions L×B×H (mm) Upper Outlet Housing Dimensions (Including Feet) Side outlet housing dimensions (including base feet)
SC(B)10-200/10 4 400 1371 0.7 42 550×550 960×750×804 1700×1400×1600 1700×1400×2200
SC(B)10-125/10 4 470 1616 0.7 43 550×550 960×750×804 1700×1400×1600 1700×1400×2200
SC(B)10-160/10 4 540 1860 0.7 43 550×550 1040×750×859 1700×1400×1600 1700×1400×2200
SC(B)10-200/10 4 620 2200 0.7 43 550×550 1040×750×874 1700×1400×1600 1700×1400×2200
SC(B)10-250/10 4 720 2410 0.7 43 660×660 1090×860×856 1700×1400×1600 1700×1400×2200
SC(B)10-315/10 4 880 3030 0.7 45 660×660 1100×860×923 1700×1400×1600 1700×1400×2200
SC(B)10-400/10 4 975 3480 0.7 45 660×660 1120×860×913 1700×1400×1600 1700×1400×2200
SC(B)10-500/10 4 1160 4260 0.6 46 660×660 1240×860×953 1700×1400×1600 1700×1400×2200
SC(B)10-630/10 4 1340 5134 0.6 46 820×660 1360×860×956 1900×1500×1800 1900×1500×2200
SC(B)10-630/10 6 1300 5200 0.6 48 820×660 1380×860×938 1900×1500×1800 1900×1500×2200
SC(B)10-800/10 6 1520 6020 0.5 49 820×820 1450×1020×993 1900×1500×1800 1900×1500×2200
SC(B)10-1000/10 6 1770 7090 0.4 50 820×820 1510×1020×1058 1900×1500×1800 1900×1500×2200
SC(B)10-1250/10 6 2090 8460 0.4 51 820×820 1530×1020×1140 1900×1500×1800 1900×1500×2200
SC(B)10-1600/10 6 2450 10240 0.3 51 820×1070 1560×1150×1223 2000×1600×2000 2000×1600×2200
SC(B)10-2000/10 6 3050 12600 0.3 52 1070×1070 1580×1150×1273 2000×1600×2000 2000×1600×2200
SC(B)10-2500/10 6 3600 15000 0.3 53 1070×1070 1700×1150×1383 2200×1600×2000 2200×1600×2200
SC(B)10-1600/10 8 2450 11263 0.3 51 820×1070 1590×1150×1198 2000×1600×2000 2000×1600×2200
SC(B)10-2000/10 8 3050 13882 0.3 52 1070×1070 1660×1150×1298 2000×1600×2000 2000×1600×2200
SC(B)10-2500/10 8 3600 16414 0.3 53 1070×1070 1720×1150×1493 2200×1600×2000 2200×1600×2200

 

Contact now

 

SC(B)11-100~2500/10 Dry-type Isolation Transformer

Rated Voltage: 10(10.5,11,6.6,6.3,6)kV

Connection Group: Dyn11 or Yyn0

Rated Low Voltage: 0.4kV

Tap Range: ±2×2.5% etc.

Product Model UK% No-load Loss P0(W) Load Loss (75℃) Pk(W) I0(%) LPA(AN)dB Wheelbase m×n Core Dimensions L×B×H(mm) Top Outlet Enclosure Dimensions (including base feet) Side Outlet Enclosure
SC(B)11-100/10 4 360 1371 0.7 42 550×550 960×750×804 1700×1400×1600 1700×1400×2200
SC(B)11-125/10 4 375 1616 0.7 43 550×550 960×750×804 1700×1400×1600 1700×1400×2200
SC(B)11-160/10 4 486 1860 0.7 43 550×550 1040×750×859 1700×1400×1600 1700×1400×2200
SC(B)11-200/10 4 560 2200 0.7 43 550×550 1040×750×874 1700×1400×1600 1700×1400×2200
SC(B)11-250/10 4 650 2410 0.7 43 660×660 1090×860×856 1700×1400×1600 1700×1400×2200
SC(B)11-315/10 4 790 3030 0.7 45 660×660 1100×860×923 1700×1400×1600 1700×1400×2200
SC(B)11-400/10 4 880 3480 0.7 45 660×660 1120×860×913 1700×1400×1600 1700×1400×2200
SC(B)11-500/10 4 1050 4260 0.6 46 660×660 1240×860×953 1700×1400×1600 1700×1400×2200
SC(B)11-630/10 4 1210 5200 0.6 46 820×660 1360×860×956 1900×1500×1800 1900×1500×2200
SC(B)11-630/10 6 1180 5200 0.6 48 820×660 1380×860×938 1900×1500×1800 1900×1500×2200
SC(B)11-800/10 6 1370 6020 0.5 49 820×820 1450×1020×993 1900×1500×1800 1900×1500×2200
SC(B)11-1000/10 6 1600 7090 0.4 50 820×820 1510×1020×1058 1900×1500×1800 1900×1500×2200
SC(B)11-1250/10 6 1880 8460 0.4 51 820×820 1530×1020×1140 1900×1500×1800 1900×1500×2200
SC(B)11-1600/10 6 2210 10240 0.3 51 820×1070 1560×1150×1223 2000×1600×2000 2000×1600×2200
SC(B)11-2000/10 6 2780 12600 0.3 52 1070×1070 1580×1150×1273 2000×1600×2000 2000×1600×2200
SC(B)11-2500/10 6 3240 15000 0.3 53 1070×1070 1700×1150×1383 2200×1600×2000 2200×1600×2200
SC(B)11-1600/10 8 2210 11263 0.3 51 820×1070 1590×1150×1198 2000×1600×2000 2000×1600×2200
SC(B)11-2000/10 8 2780 13882 0.3 52 1070×1070 1660×1150×1298 2000×1600×2000 2000×1600×2200
SC(B)11-2500/10 8 3240 16414 0.3 53 1070×1070 1720×1150×1493 2200×1600×2000 2200×1600×2200

 

Contact now

 

SC(B)12-100~2500/10 dry-type isolation transformer

Rated voltage: 10 (10.5, 11, 6.6, 6.3, 6) kV

Connection group: Dyn11 or Yyn0

Rated low voltage: 0.4 kV

Tap range: ±2×2.5% etc.

Product Model UK% No-load Loss P0(W) Load Loss (75℃) Pk(W) I0(%) LPA(AN)dB Wheelbase m×n Core Dimensions L×B×H(mm) Top Outlet Enclosure Dimensions (including base feet) Side Outlet Enclosure
SC(B)12-100/10 4 320 1371 0.7 42 550×550 960×750×810 1700×1400×1600 1700×1400×2200
SC(B)12-125/10 4 375 1616 0.7 43 550×550 960×750×810 1700×1400×1600 1700×1400×2200
SC(B)12-160/10 4 430 1860 0.7 43 550×550 1050×750×860 1700×1400×1600 1700×1400×2200
SC(B)12-200/10 4 495 2200 0.7 43 550×550 1060×750×880 1700×1400×1600 1700×1400×2200
SC(B)12-250/10 4 575 2410 0.7 43 660×660 1000×860×860 1700×1400×1600 1700×1400×2200
SC(B)12-315/10 4 705 3030 0.7 45 660×660 1030×860×996 1700×1400×1600 1700×1400×2200
SC(B)12-400/10 4 785 3480 0.7 45 660×660 1050×860×1041 1700×1400×1600 1700×1400×2200
SC(B)12-500/10 4 930 4260 0.6 46 660×660 1090×860×1190 1700×1400×1600 1700×1400×2200
SC(B)12-630/10 4 1070 5200 0.6 46 820×660 1170×860×1256 1900×1500×1800 1900×1500×2200
SC(B)12-630/10 6 1040 5200 0.6 48 820×660 1210×860×1123 1900×1500×1800 1900×1500×2200
SC(B)12-800/10 6 1215 6020 0.5 49 820×820 1230×1020×1161 1900×1500×1800 1900×1500×2200
SC(B)12-1000/10 6 1415 7090 0.4 50 820×820 1320×1020×1247 1900×1500×1800 1900×1500×2200
SC(B)12-1250/10 6 1670 8460 0.4 51 820×820 1420×1020×1133 1900×1500×1800 1900×1500×2200
SC(B)12-1600/10 6 1960 10240 0.3 51 820×1070 1490×1150×1398 2000×1600×2000 2000×1600×2200
SC(B)12-2000/10 6 2440 12600 0.3 52 1070×1070 1500×1150×1408 2000×1600×2000 2000×1600×2200
SC(B)12-2500/10 6 2880 15000 0.3 53 1070×1070 1570×1150×1483 2200×1600×2000 2200×1600×2200
SC(B)12-1600/10 8 1960 11263 0.3 51 820×1070 1530×1150×1350 2000×1600×2000 2000×1600×2200
SC(B)12-2000/10 8 2440 13882 0.3 52 1070×1070 1610×1150×1416 2000×1600×2000 2000×1600×2200
SC(B)12-2500/10 8 2880 16414 0.3 53 1070×1070 1720×1150×1508 2200×1600×2000 2200×1600×2200

 

Contact now

 

SC(B)13-100~2500/10 dry-type isolation transformer

Rated voltage: 10 (10.5, 11, 6.6, 6.3, 6) kV

Connection group: Dyn11 or Yyn0

Rated low voltage: 0.4 kV

Tap range: ±2×2.5% etc.

Product Model UK% No-load Loss P0(W) Load Loss (75℃) Pk(W) I0(%) LPA(AN)dB 轨矩m×n Wheelbase m×n Core Dimensions L×B×H(mm) Top Outlet Enclosure Dimensions (including base feet) Side Outlet Enclosure
SC(B)13-100/10 4 290 1236 0.7 42 550×550 990×750×790 1700×1400×1600 1700×1400×2200
SC(B)13-125/10 4 340 1454 0.7 43 550×550 990×750×830 1700×1400×1600 1700×1400×2200
SC(B)13-160/10 4 385 1672 0.7 43 550×550 1060×750×880 1700×1400×1600 1700×1400×2200
SC(B)13-200/10 4 445 1990 0.7 43 660×660 980×860×900 1700×1400×1600 1700×1400×2200
SC(B)13-250/10 4 515 2170 0.7 43 660×660 1000×860×920.5 1700×1400×1600 1700×1400×2200
SC(B)13-315/10 4 635 2730 0.7 45 660×660 1030×860×996 1700×1400×1600 1700×1400×2200
SC(B)13-400/10 4 705 3135 0.7 45 660×660 1060×860×1038 1700×1400×1600 1700×1400×2200
SC(B)13-500/10 4 835 3835 0.6 46 660×660 1120×860×1180 1700×1400×1600 1700×1400×2200
SC(B)13-630/10 4 965 4620 0.6 46 820×660 1170×860×1256 1900×1500×1800 1900×1500×2200
SC(B)13-630/10 6 935 4685 0.6 48 820×660 1210×860×1103 1900×1500×1800 1900×1500×2200
SC(B)13-800/10 6 1095 5470 0.5 49 820×820 1230×1020×1161 1900×1500×1800 1900×1500×2200
SC(B)13-1000/10 6 1275 6390 0.4 50 820×820 1320×1020×1274 1900×1500×1800 1900×1500×2200
SC(B)13-1250/10 6 1505 7615 0.4 51 820×820 1350×1020×1353 1900×1500×1800 1900×1500×2200
SC(B)13-1600/10 6 1765 9215 0.3 51 820×1070 1390×1150×1373 2000×1600×2000 2000×1600×2200
SC(B)13-2000/10 6 2195 11355 0.3 52 1070×1070 1500×1150×1426 2000×1600×2000 2000×1600×2200
SC(B)13-2500/10 6 2590 13495 0.3 53 1070×1070 1570×1150×1483 2200×1600×2000 2200×1600×2200
SC(B)13-1600/10 8 1715 10137 0.3 51 820×1070 1610×1150×1273 2000×1600×2000 2000×1600×2200
SC(B)13-2000/10 8 2135 12494 0.3 52 1070×1070 1610×1150×1416 2000×1600×2000 2000×1600×2200
SC(B)13-2500/10 8 2520 14773 0.3 53 1070×1070 1610×1150×1563 2200×1600×2000 2200×1600×2200

 

Contact now

 

SC(B)14-100~2500/10 dry-type isolation transformer

Rated voltage: 10 (10.5, 11, 6.6, 6.3, 6) kV

Connection group: Dyn11 or Yyn0

Rated low voltage: 0.4 kV

Tap range: ±2×2.5% etc.

Product Model UK% No-load Loss P0(W) Load Loss (75℃) Pk(W) I0(%) LPA(AN)dB Wheelbase m×n Core Dimensions L×B×H(mm) Top Outlet Enclosure Dimensions (including base feet) Side Outlet Enclosure
SC(B)14-100/10 4 270 1240 0.7 42 550×550 1050×750×790 1700×1400×1600 1700×1400×2200
SC(B)14-125/10 4 320 1450 0.7 43 550×550 1050×750×830 1700×1400×1600 1700×1400×2200
SC(B)14-160/10 4 365 1670 0.7 43 550×550 1100×750×880 1700×1400×1600 1700×1400×2200
SC(B)14-200/10 4 420 1990 0.7 43 660×660 1090×750×900 1700×1400×1600 1700×1400×2200
SC(B)14-250/10 4 490 2170 0.7 43 660×660 1150×860×940 1700×1400×1600 1700×1400×2200
SC(B)14-315/10 4 600 2730 0.7 45 660×660 1180×860×970 1700×1400×1600 1700×1400×2200
SC(B)14-400/10 4 665 3140 0.7 45 660×660 1290×860×990 1700×1400×1600 1700×1400×2200
SC(B)14-500/10 4 790 3830 0.6 46 660×660 1260×860×1030 1700×1400×1600 1700×1400×2200
SC(B)14-630/10 4 910 4610 0.6 46 820×660 1300×860×1120 1900×1500×1800 1900×1500×2200
SC(B)14-630/10 6 885 5690 0.6 48 820×660 1390×860×1060 1900×1500×1800 1900×1500×2200
SC(B)14-800/10 6 1035 5470 0.5 49 820×820 1450×1020×1070 1900×1500×1800 1900×1500×2200
SC(B)14-1000/10 6 1205 6430 0.4 50 820×820 1510×1020×1110 1900×1500×1800 1900×1500×2200
SC(B)14-1250/10 6 1420 7610 0.4 51 820×820 1540×1020×1160 1900×1500×1800 1900×1500×2200
SC(B)14-1600/10 6 1665 9230 0.3 51 820×1070 1650×1150×1230 2000×1600×2000 2000×1600×2200
SC(B)14-2000/10 6 2075 11420 0.3 52 1070×1070 1730×1150×1330 2000×1600×2000 2000×1600×2200
SC(B)14-2500/10 6 2450 13540 0.3 53 1070×1070 1810×1150×1370 2200×1600×2000 2200×1600×2200
SC(B)14-1600/10 8 1665 10160 0.3 51 820×1070 1650×1150×1190 2000×1600×2000 2000×1600×2200
SC(B)14-2000/10 8 2075 12530 0.3 52 1070×1070 1730×1150×1300 2000×1600×2000 2000×1600×2200
SC(B)14-2500/10 8 2450 14830 0.3 53 1070×1070 1810×1150×1320 2200×1600×2000 2200×1600×2200

 

Contact now

 

SC(B)18-100~2500/10 dry-type isolation transformer

Rated voltage: 10 (10.5, 11, 6.6, 6.3, 6) kV

Connection group: Dyn11 or Yyn0

Rated low voltage: 0.4 kV

Tap range: ±2×2.5% etc.

Product Model UK% No-load Loss P0(W) Load Loss (75℃) I0(%) LPA(AN)dB Wheelbase m×n Core Dimensions L×B×H(mm) Top Outlet Enclosure Dimensions (including base feet) Side Outlet Enclosure
SC(B)18-100/10 4 230 1240 0.7 42 550×550 1050×750×790 1700×1400×1600 1700×1400×2200
SC(B)18-125/10 4 270 1450 0.7 43 550×550 1050×750×830 1700×1400×1600 1700×1400×2200
SC(B)18-160/10 4 310 1670 0.7 43 550×550 1100×750×880 1700×1400×1600 1700×1400×2200
SC(B)18-200/10 4 360 1990 0.7 43 660×660 1090×750×900 1700×1400×1600 1700×1400×2200
SC(B)18-250/10 4 415 2170 0.7 43 660×660 1150×860×940 1700×1400×1600 1700×1400×2200
SC(B)18-315/10 4 510 2730 0.7 45 660×660 1180×860×970 1700×1400×1600 1700×1400×2200
SC(B)18-400/10 4 570 3140 0.7 45 660×660 1290×860×990 1700×1400×1600 1700×1400×2200
SC(B)18-500/10 4 670 3830 0.6 46 660×660 1260×860×1030 1700×1400×1600 1700×1400×2200
SC(B)18-630/10 4 775 4610 0.6 46 820×660 1300×860×1120 1900×1500×1800 1900×1500×2200
SC(B)18-630/10 6 750 5690 0.6 48 820×660 1390×860×1060 1900×1500×1800 1900×1500×2200
SC(B)18-800/10 6 875 5470 0.5 49 820×820 1450×1020×1070 1900×1500×1800 1900×1500×2200
SC(B)18-1000/10 6 1020 6430 0.4 50 820×820 1510×1020×1110 1900×1500×1800 1900×1500×2200
SC(B)18-1250/10 6 1205 7610 0.4 51 820×820 1540×1020×1160 1900×1500×1800 1900×1500×2200
SC(B)18-1600/10 6 1415 9230 0.3 51 820×1070 1650×1150×1230 2000×1600×2000 2000×1600×2200
SC(B)18-2000/10 6 1760 11420 0.3 52 1070×1070 1730×1150×1330 2000×1600×2000 2000×1600×2200
SC(B)18-2500/10 6 2080 13540 0.3 53 1070×1070 1810×1150×1370 2200×1600×2000 2200×1600×2200
SC(B)18-1600/10 8 1415 10160 0.3 51 820×1070 1650×1150×1190 2000×1600×2000 2000×1600×2200
SC(B)18-2000/10 8 1760 12530 0.3 52 1070×1070 1730×1150×1300 2000×1600×2000 2000×1600×2200
SC(B)18-2500/10 8 2080 14830 0.3 53 1070×1070 1810×1150×1320 2200×1600×2000 2200×1600×2200

 

Contact now

 

SC(B)10-200~2500/20 dry-type isolation transformer

Rated voltage: 20(22,24) kV

Connection group: Dyn11 or Yyn0

Rated low voltage: 0.4 kV

Insulation level: LI 125 AC 50/LI AC 3

Tap range: ±2×2.5% etc.

Product Model UK% No-load Loss P0(W) Load Loss (75℃) Pk(W) I0(%) LPA(AN)dB Wheelbase m×n Core Dimensions L×B×H(mm) Enclosure dimensions (including base feet)
SC(B)10-200/20 6 730 2565 1 47 660×660 1425×860×1184 1650×1400×1660
SC(B)10-250/20 6 840 2985 1 47 820×660 1450×860×1317 2000×1400×1660
SC(B)10-315/20 6 970 3560 0.9 48 820×820 1460×1020×1339 2000×1400×1865
SC(B)10-400/20 6 1150 4225 0.8 48 820×820 1490×1020×1344 2100×1450×1965
SC(B)10-500/20 6 1350 5055 0.8 50 820×820 1580×1070×1471 2100×1450×1965
SC(B)10-630/20 6 1530 5970 0.7 50 820×820 1580×1070×1616 2200×1500×2065
SC(B)10-800/20 6 1750 7210 0.6 51 820×820 1580×1070×1681 2300×1550×2065
SC(B)10-1000/20 6 2070 8540 0.5 52 820×820 1700×1070×1563 2300×1650×2165
SC(B)10-1250/20 6 2380 10040 0.5 52 1070×1070 1760×1270×1621 2400×1700×2300
SC(B)10-1600/20 6 2790 12050 0.4 53 1070×1070 1900×1270×1781 2500×1800×2400
SC(B)10-2000/20 6 3240 14230 0.4 53 1070×1070 2060×1270×2081 2700×1800×2500
SC(B)10-2500/20 6 3870 16850 0.3 54 1070×1070 2260×1270×2016 2800×1900×2700

 

Contact now

 

SC(B)10-250~2500/35 dry-type isolation transformer

Rated voltage: 35 (38.5, 37.5, 36.5, 33) kV

Connection group: Dyn11, Yyn0

Rated low voltage: 0.4 kV

Tap range: ±2×2.5% etc.

Product Model UK% No-load Loss P0(W) Load Loss (75℃) Pk(W) I0(%) LPA(AN)dB Wheelbase m×n Core Dimensions L×B×H(mm) Enclosure dimensions (including base feet)
SC10-250/35 6 990 3250 0.73 52 820×820 1470×1000×1591 2300×1700×2000
SC10-315/35 6 1180 3900 0.6 52 820×820 1580×1100×1870 2600×1800×2300
SC10-400/35 6 1380 4700 1.6 52 820×820 1790×1100×1700 2600×1800×2100
SC(B)10-500/35 6 1620 5700 0.43 52 820×820 1620×1100×1930 2420×1800×2300
SC(B)10-630/35 6 1860 6600 0.36 52 820×820 1720×1100×1970 2520×1900×2350
SC(B)10-800/35 6 2160 7800 0.63 53 820×820 1840×1200×2000 2650×1900×2350
SC(B)10-1000/35 6 2430 9100 0.47 53 1070×820 2070×1200×1980 2870×1900×2350
SC(B)10-1250/35 6 2840 11000 0.4 53 1070×1070 2180×1400×2000 2980×2000×2450
SC(B)10-1600/35 6 3240 13400 0.3 55 1070×1070 2000×1300×2270 2800×2000×2650
SC(B)10-2000/35 6 3825 15928 0.28 55 1070×1070 2130×1300×2340 3200×2200×2700
SC(B)10-2500/35 6 4460 18641 0.52 55 1070×1070 2240×1400×2370 3000×2000×2700

 

Contact now

 

 

SC11-800~25000/35 Dry-type Isolation Transformer

Rated Voltage: 35(38.5,37.5,36.5,33)kV

Connection Group: Yd11, YNd1 or Dyn11

Rated Low Voltage: 10.5(11,6.0,6.3,3.15)kV

Tap Range: ±2×2.5% etc.

Product Model UK% No-load Loss P0(W) Load Loss (75℃) Pk(W) I0(%) LPA(AN)dB Core Dimensions L×B×H(mm) Overall dimensions L×B×H(mm)
SC11-800/35 6 2025 9400 0.6 50 1475×820 2210×1070×1680
SC11-1000/35 6 2400 10900 0.6 50 1475×820 2280×1070×1720
SC11-1250/35 6 2815 12900 0.5 50 1475×1070 2380×1200×1810
SC11-1600/35 6 3320 15400 0.5 50 1475×1070 2405×1400×2285
SC11-2000/35 7 3805 18200 0.45 52 1475×1070 2530×1400×2330
SC11-2500/35 7 4370 21800 0.45 52 1475×1070 2650×1400×2345
SC11-3150/35 8 5425 24500 0.4 53 2040×1475 2980×1400×2360
SC11-4000/35 8 6315 29400 0.4 53 2040×1475 3120×1600×2410
SC11-5000/35 8 7530 34900 0.35 54 2040×1475 3170×1600×2460
SC11-6300/35 8 8910 40800 0.35 54 2040×1475 3250×1800×2565
SC11-8000/35 9 10170 46000 0.3 56 2040×1475 3390×1800×2675
SC11-10000/35 9 11610 55500 0.25 60 2040×1475 3570×2000×2765
SC11-12500/35 9 14130 64600 0.2 60 2040×1475 3770×2000×2885
SC11-16000/35 9 17370 76000 0.2 62 2300×1475 4200×2000×3150
SC11-20000/35 10 20610 85500 0.2 62 2580×1475 4610×2000×3460
SC11-25000/35 10 24390 101000 0.2 64 2580×1475 4810×2000×3490

 

 

Contact now

 

 

 

Core Advantages Of SC(B) Dry Type Isolation Transformer

 

1. Electrical Isolation:
As a Dry Type Isolation Transformer, it uses epoxy resin insulation layers to completely isolate primary and secondary circuits, ensuring personnel and equipment safety. This is critical for sensitive applications like healthcare and laboratories.

2. Safety & Reliability:
The Cast Resin Isolation Dry Type Transformer employs oil-free design to eliminate fire hazards, with robust short-circuit resistance (short-circuit impedance ≥10%) and compliance with ISO/SGS certifications for international safety standards.

3. Application Adaptability:
Supports 3 phase dry type transformer three-phase balanced output, accommodating industrial power demands and adapting to harsh environments (e.g., high temperature, humidity, or corrosive gases in power plants and chemical facilities).

4. Superior Performance:
Copper foil winding and vacuum casting technology achieve impedance voltage ≤6%, enhancing power factor and load capacity while minimizing operational losses for consistent power quality and long-term reliability.

 

 

 

video

 

 

 

Application Areas and Environments

 

The SC(B) Dry Type Isolation Transformer is widely deployed in high-safety, fire-resistant settings:

Industrial Plants:

Provides stable 3 phase dry type transformer power for production equipment while isolating high-voltage system risks.

Semiconductor Manufacturing:

Utilizes Cast Resin Isolation technology to meet cleanroom requirements for oil-free, low-interference power supply.

Power Plants & Distribution Centers:

Isolates critical equipment circuits to prevent fault propagation, boosting overall grid reliability.

Transportation & Data Centers:

Ensures continuous power in high-temperature, high-load environments, with harmonic resistance compatible with UPS systems.
The product operates reliably in temperatures from -20°C to 155°C, resisting corrosion from salt mist, dust, and other harsh conditions.

 

Dry Type Isolation Transformer

 

 

Contact now

 

 

 

Why choose us?

 

 

GNEE Group:

Global Transformer Supply Chain Integration Expert (2008 - Present)

Founded in 2008, GNEE Group has undergone fifteen years of deep industry cultivation, successfully transforming from a regional trader to a global supply chain management expert. As a pioneer in the integration of the steel industry chain, the group has established a full-cycle value system that spans raw material procurement, production coordination, logistics optimization, and terminal services, setting an innovative operational benchmark in the global transformer distribution sector. In the era of Industry 4.0, GNEE Group is accelerating towards its goal of becoming a global integrator of transformer industry value through digital restructuring and green supply chain construction.

 

Dry Type Isolation Transformer

Dry Type Isolation Transformer

 

SGS certification certificate

Dry Type Isolation Transformer

 

Packing and Delivery

Dry Type Isolation Transformer

 

FAQ

Q: Why is the oil-filled design critical for distribution transformers?

A: Oil filled distribution transformers use oil to cool windings efficiently, preventing overheating. This ensures stable power output under heavy loads while minimizing maintenance needs.

Q: What makes the oil immersed type transformer energy-efficient?

A: Our oil immersed type transformer combines high-grade silicon steel cores with optimized windings, reducing both no-load and load losses by up to 30%. This lowers operational costs over time.

Q: How does a three-phase oil immersed transformer benefit industrial projects?

A: The three phase oil immersed transformer supports balanced power distribution for large-scale equipment, ensuring consistent performance in factories or power substations.

Q: What is the difference between an "immersed transformer" and a standard dry-type transformer?

A: An immersed transformer uses oil for insulation and cooling, making it safer for high-voltage applications. Dry types lack oil but may require forced cooling, making them less efficient in harsh conditions.

 

Contact now

 

Hot Tags: sc(b) dry type isolation transformer, China sc(b) dry type isolation transformer manufacturers, suppliers, factory, 1500 kva dry type transformer, 6 6KV Transformer, Dry type Amorphous core transformer, amorphous steel transformer, 3 phase dry type transformer, Cast Dry Type Transformer

Send Inquiry