AWG Enameled Copper Wire: Sizes, Thermal Classes and Selection for CT and PT Windings

Oct 21, 2025

Leave a message

What Is AWG Enameled Copper Wire?

AWG enameled copper wire is a round copper conductor coated with a continuous film of insulating enamel. The American Wire Gauge system defines the conductor diameter, while the enamel film provides electrical insulation between adjacent turns. This type of magnet wire is essential for the coil windings of current transformers, voltage transformers, inductors, motors and dry-type transformer windings. In instrument transformer service, the wire must withstand epoxy encapsulation and operating voltages from 3 kV up to 36 kV, so insulation integrity and uniform coating are critical.

AWG Sizes and Conductor Diameters

Enameled copper wire for CT and PT windings is commonly supplied in sizes from AWG 4 to AWG 34. The table below lists representative sizes and their typical uses.

AWG Size Diameter mm Typical Application
AWG 8 3.26 High-current primary windings
AWG 12 2.05 Medium-power applications
AWG 16 1.29 Control circuits
AWG 17 1.15 Secondary windings
AWG 30 0.255 Precision low-power windings
AWG 31 0.227 Micro-coil applications

Thermal Classes and Insulation Systems

The thermal class of an enameled wire defines the maximum continuous operating temperature of its insulation system. According to IEC 60085 and the winding wire standard IEC 60317-0-1, class B is rated 130 °C, class F 155 °C, class H 180 °C and class 200 is rated 200 °C. Polyesterimide enameled copper wire combines good thermal endurance with excellent mechanical properties and is commonly supplied with a 200 °C thermal rating for instrument transformer applications; lower ratings of 155 °C and 180 °C are available where operating temperatures are moderate.

Thermal Class Maximum Temperature °C Typical Suitability
Class B 130 Standard low-temperature applications
Class F 155 Moderate temperature rise designs
Class H 180 High-temperature environments
Class 200 200 Severe thermal duty, CT and PT windings

How to Select Enameled Copper Wire for CT and PT Windings

Selection involves three steps. First, choose the conductor diameter that satisfies the required current density and fits the available window space of the core. Second, verify the thermal class against the hottest-spot temperature of the finished coil. Third, confirm that the enamel grade meets the dielectric strength, cut-through resistance and abrasion requirements of the manufacturing process. For encapsulated instrument transformers, good adhesion of the enamel film and resistance to thermal shock are essential because the wire must survive the epoxy curing cycle. All wires supplied for this service should comply with the IEC 60317 series, and the insulation thickness grade, grade 1, 2 or 3, is chosen according to the voltage stress of the design.

Areas of Application

Beyond instrument transformers, AWG enameled copper wire is used in power transformers, inductors and reactors, dry-type transformer coil winding, high-speed wound motors, solenoids and many small electromagnetic devices. The combination of a small conductor diameter, uniform enamel film and high copper fill factor makes it the standard choice wherever compact and reliable coils are required.

FAQ

Q: What is the difference between AWG sizes and metric wire sizes?

A: The AWG system uses a logarithmic gauge number in which larger numbers indicate smaller conductor diameters, while metric sizes are expressed directly in millimetres; conversion tables in IEC 60317 are used when specifying round winding wire.

Q: Which thermal class should be selected for a current transformer winding?

A: It depends on the hottest-spot temperature: class F is common for moderate designs, while class H or class 200 is preferred when the transformer operates in a high ambient temperature or is subjected to heavy overloads.

Q: What does the insulation thickness grade mean?

A: Grade 1 is a thin coating, grade 2 is standard and grade 3 is a thick coating; the grade affects the dielectric strength and the space factor of the winding and is selected according to the voltage stress and mechanical duty.

Q: Why is polyesterimide enamel commonly used?

A: Polyesterimide enamel offers a good balance of thermal endurance, mechanical strength, chemical resistance and dielectric properties, making it suitable for a wide range of motor, transformer and instrument windings.

Q: Can enameled copper wire be used for high-voltage windings?

A: Yes, within the limits of the enamel system; for higher voltages, the turns are often further insulated with additional layers or the winding is encapsulated, and the design must meet the partial discharge and impulse requirements of the applicable standard.

Q: How is the enamel coating tested for quality?

A: Standard tests include dielectric breakdown voltage, cut-through temperature, heat shock, flexibility and adhesion, and abrasion resistance, as specified in the IEC 60317 series.