What Is The Structure Of A Three-phase Fully Sealed All-copper Transformer?
Feb 17, 2025
Leave a message
What is the structure of a three-phase fully sealed all-copper transformer?
The three-phase fully sealed all-copper transformer is an efficient and reliable power equipment, and its structural design is designed to achieve high insulation, low loss and long life. The following are its main structural features:
1. Iron core
It is made of high-quality silicon steel sheets, and the iron core structure is usually three-phase five-column or three-phase three-column to reduce magnetic resistance and iron loss.
The surface of the iron core is insulated to prevent eddy current loss.
2. Winding
All-copper winding: Both high and low voltage windings use high-purity electrolytic copper wires with excellent conductivity, low resistance and low loss.
Insulation treatment: The winding is wrapped with multiple layers of insulating paper or film, and is treated with varnish and drying to enhance insulation strength and heat resistance.
3. Oil tank and sealing structure
Fully sealed design: The transformer oil tank adopts a welded sealing structure to prevent the oil from contacting the outside air and avoid oxidation and moisture.
Corrugated oil tank or expander: used to adjust the volume change of oil to ensure stable internal pressure.
4. Cooling system
Oil-immersed cooling: The transformer is filled with insulating oil, and the heat is dissipated through natural convection or forced circulation of the oil.
Heat sink or heat pipe: Heat sink or heat pipe is installed outside the oil tank to increase the heat dissipation area.
5. Protective device
Pressure relief valve: Prevent internal pressure from being too high.
Gas relay (gas relay): Monitor internal fault gas and provide fault warning.
Temperature controller: Real-time monitoring of oil temperature to prevent overheating.
6. Outlet device
The high and low voltage outlet terminals adopt a fully sealed structure, usually equipped with porcelain bushings or epoxy resin bushings to ensure insulation and moisture resistance.
7. Accessories
Oil level gauge: Monitor oil level changes.
Desiccant (respirator): Used in non-fully sealed parts to prevent moisture from entering.
The three-phase fully sealed all-copper transformer has a compact structure and reliable operation. It is suitable for occasions with high requirements for safety and efficiency, such as urban power grids, industrial and mining enterprises, and high-rise buildings.