110kV 6300kVA-63000kVA Oil Immersed Power Transformer
Phase:Three Phase
High Voltage:110kV-121kV
Low Voltage:6.3kV-21kV
Rated Capacity: 6300kVA-63000kVA
Vector Group:YNd11, YNyn0, d11
Service:Customized Service
Certifications: ISO, SGS
Key Advantages: High reliability, energy efficiency, compact design, and dual international certifications.
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 110kv 6300kva-63000kva oil immersed power transformer in China. If you're going to buy customized 110kv 6300kva-63000kva oil immersed power transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
Product Introduction
of 110kV Oil Immersed Power Transformer
The 110kV 6300kVA-63000kVA Oil-Immersed Power Transformer is a high-performance solution for large-scale power transmission and distribution. Designed for demanding applications such as industrial complexes, power grids, and infrastructure projects, it ensures stable voltage conversion from 110kV three-phase input to customized output. With energy-efficient silicon steel cores and advanced cooling systems, it reduces operational losses by 25%, lowering energy costs. The fully sealed oil-immersed structure prevents leakage, corrosion, and external interference, while meeting ISO and SGS standards for safety and environmental compliance.

Basic Structure & Key Features

Structure:
Oil-Immersion System: Fully sealed tank filled with insulating oil, ensuring optimal heat dissipation and insulation.
Three-Phase Core and Winding: High-quality silicon steel core and copper windings for minimal energy loss, even under heavy loads.
Pressure Relief Valve: Automatically releases excess pressure to prevent damage during short circuits.
Temperature Monitoring: Embedded sensors enable real-time tracking of oil and winding temperatures.
Core Features:
Energy Efficiency: Low-noise design and low-loss materials meet IEC energy standards.
Safety: Fire-resistant oil and explosion-proof casing comply with IEC 60076 and fire-resistant requirements.
Adaptability: Operates in temperatures from -40°C to +50°C and high-humidity environments.
Scalability: Customizable output voltage (e.g., 6.3kV, 10.5kV) to suit diverse grid needs.
Products parameter
|
S (F)Z Series 11/ 13 - 110kV 6300- 63000kVA double winding on-load voltage regulating power transformer |
|||||||||
|
Rated Capacity( kVA) |
Voltage combination and tap range |
Vector Group |
No-load Loss (kW) |
Load Loss (kW) |
No-load Current % |
Impedance Voltage % |
|||
|
High Voltage (kV) |
Tapping Range |
Low Voltage (kV) |
Series 11 |
Series 13 |
|||||
|
6300 |
|
|
|
|
8.0 |
6.4 |
35 |
0.64 |
|
|
8000 |
9.6 |
7.68 |
42 |
0.64 |
|||||
|
10000 |
6.3 |
11.3 |
9.04 |
50 |
0.59 |
||||
|
12500 |
110 |
6.6 |
YNd11 |
13.4 |
10.72 |
59 |
0.59 |
||
|
16000 |
121 |
8 x 1.25% |
10.5 |
|
16.1 |
12.88 |
73 |
0.55 |
10.5 |
|
20000 |
|
|
21 |
19.2 |
15.36 |
88 |
0.55 |
|
|
|
25000 |
|
22.7 |
18.16 |
104 |
0.51 |
||||
|
31500 |
27.0 |
21.6 |
123 |
0.51 |
|||||
|
40000 |
32.3 |
28.84 |
156 |
0.46 |
12-18 |
||||
|
50000 |
38.2 |
30.56 |
194 |
0.46 |
|
||||
|
63000 |
45.4 |
36.32 |
232 |
0.42 |
|||||
Note:
1. For on-load tap changer transformers, step-down structure products are temporarily provided.
2. Negotiate with the manufacturer according to the user department products with other voltage combinations that can be provided, the maximum current tap is at -10% tap position.
|
SS(F)Z11/ 13 Model -110kV 6300- 63000kVA three-winding on-load voltage regulating transformer |
|||||||||
|
Rated Capacity( kVA) |
Voltage combination and tap range |
Vector Group |
No-load Loss (kW) |
Load Loss (kW) |
No-load Current % |
Impedance Voltage % |
|||
|
High Voltage (kV) |
Tapping Range |
Low Voltage (kV) |
11 Model |
13 Model |
|||||
|
6300 |
|
|
|
|
9.6 |
7.68 |
44 |
0.76 |
High-Medium |
|
8000 |
|
|
|
|
11.5 |
9.2 |
53 |
0.76 |
10.5 |
|
10000 |
|
36 |
6.3 |
|
13.6 |
10.88 |
62 |
0.71 |
High-Low |
|
12500 |
110± |
37 |
6.6 |
YNyn0 |
16.1 |
12.88 |
74 |
0.71 |
18-19 |
|
16000 |
8 x 1.25% |
38.5 |
10.5 |
d11 |
19.3 |
15.44 |
90 |
0.67 |
Medium-Low |
|
20000 |
|
|
21 |
|
22.8 |
18.24 |
106 |
0.67 |
6.5 |
|
25000 |
|
|
|
|
27.0 |
21.6 |
126 |
0.62 |
|
|
31500 |
|
|
|
|
32.1 |
25.68 |
149 |
0.62 |
|
|
40000 |
|
|
|
|
38.5 |
30.8 |
179 |
0.58 |
|
|
50000 |
|
|
|
|
45.5 |
36.4 |
213 |
0.58 |
|
|
63000 |
|
|
|
|
54.1 |
43.28 |
256 |
0.53 |
|
Note:
1. step-down structure products are temporarily provided for on-load tap changer transformers.
2. The capacity distribution of high, medium, and low voltage windings is (100/100/100)%.
3. The label of the connection group can be YNd11y10 as required.
4. The maximum current tap is -10% tap position.
5. According to users' needs, the voltage value or taps different from those in the table can be selected for medium voltage.
|
S (F)11/ 13 Model-110kV 6300 - 63000kVA double winding low voltage 35kV level non-excitation voltage regulating transformer |
|||||||||
|
Rated Capacity( kVA) |
Voltage combination and tap range |
Vector Group |
No-load Loss (kW) |
Load Loss (kW) |
No-load Current % |
Impedance Voltage % |
|||
|
High Voltage (kV) |
Tapping Range |
Low Voltage (kV) |
11 Model |
13 Model |
|||||
|
6300 |
|
|
|
|
8.0 |
6.4 |
37 |
0.67 |
|
|
8000 |
|
|
|
|
9.6 |
7.68 |
44 |
0.67 |
|
|
10000 |
|
|
36 |
|
11.2 |
8.96 |
52 |
0.62 |
|
|
12500 |
110 |
±2 x 2.5 |
37 |
|
13.1 |
10.48 |
62 |
0.62 |
|
|
16000 |
115 |
|
38.5 |
YNd11 |
15.6 |
12.48 |
76 |
0.57 |
|
|
20000 |
121 |
|
|
|
18.5 |
14.8 |
94 |
0.57 |
10.5 |
|
25000 |
|
|
|
|
21.9 |
17.52 |
110 |
0.53 |
|
|
31500 |
|
|
|
|
25.9 |
20.72 |
133 |
0.53 |
|
|
40000 |
|
|
|
|
30.8 |
24.64 |
155 |
0.49 |
|
|
50000 |
|
|
|
|
36.9 |
29.52 |
193 |
0.49 |
|
|
63000 |
|
|
|
|
43.6 |
34.88 |
232 |
0.45 |
|
Product Testing

Product Testing
The 110kV three phase oil immersed transformer undergoes rigorous testing to ensure performance and safety:
Electrical Testing: Short-circuit withstand capability, partial discharge, and insulation resistance.
Mechanical Testing: Vibration and seismic resistance under IEC 60076 standards.
Environmental Testing: Temperature cycling (-40°C to +50°C) and humidity corrosion resistance.
Safety Compliance: Oil leakage prevention, SF6 gas detection (optional), and fire resistance validation.
All tests align with ISO and SGS certifications, guaranteeing product reliability for global markets.
Why choose us?
GNEE strictly follows the comprehensive acceptance testing process to ensure that the performance of each device meets the standards. Our products and services have been successfully applied in more than 50 countries and regions around the world. As a trusted global industrial partner, we are always committed to helping customers achieve their sustainable development vision through high-quality products and full-process services.
Support
• Pre-sales: Free technical consulting, drawing review, and installation training.
• After-sales:
o Global warranty for 2 years; 5-year warranty on core components.
o 7×24-hour remote support, fault response within <24 hours.
o Operation manual provided.
Product Testing Center

SGS certification certificate

Packing and Delivery

FAQ
Q: Why is the oil-filled design critical for distribution transformers?
A: Oil filled distribution transformers use oil to cool windings efficiently, preventing overheating. This ensures stable power output under heavy loads while minimizing maintenance needs.
Q: What makes the oil immersed type transformer energy-efficient?
A: Our oil immersed type transformer combines high-grade silicon steel cores with optimized windings, reducing both no-load and load losses by up to 30%. This lowers operational costs over time.
Q: How does a three-phase oil immersed transformer benefit industrial projects?
A: The three phase oil immersed transformer supports balanced power distribution for large-scale equipment, ensuring consistent performance in factories or power substations.
Q: What is the difference between an "immersed transformer" and a standard dry-type transformer?
A: An immersed transformer uses oil for insulation and cooling, making it safer for high-voltage applications. Dry types lack oil but may require forced cooling, making them less efficient in harsh conditions.
Hot Tags: 110kv 6300kva-63000kva oil immersed power transformer, China 110kv 6300kva-63000kva oil immersed power transformer manufacturers, suppliers, factory, transformer capacity standard, S13 Outdoor Transformers, 75kVA Oil-Immersed Distribution Transformers, S M Series Oil Immersed Power Transformer, transformer anti corrosion treatment, transformer oil spill containment
You Might Also Like