11kV 500kVA Oil Immersed Transformer

11kV 500kVA Oil Immersed Transformer

We focus on the development and design of 11kv 500kVA Electric Voltage Power Oil-Immersed Transformer solutions. We invite you to definitely pay a visit to our business for a personalized tour and advanced small business guidance. This 500KVA transformer was delivered to Egypt in 2022. the rated...
Send Inquiry
Chat Now

Have questions? GNEE sales representatives are available for live chat now

Send E-mail: sales@gneeelectric.com

Tel: +8615824687445

Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 11kv 500kva oil immersed transformer in China. If you're going to buy customized 11kv 500kva oil immersed transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.

 

We focus on the development and design of 11kv 500kVA Electric Voltage Power Oil-Immersed Transformer solutions. We invite you to definitely pay a visit to our business for a personalized tour and advanced small business guidance.

 

This 500KVA transformer was delivered to Egypt in 2022. the rated power of the transformer is 500 KVA.

Standards: BS EN 60076

Rated Power: 500kVA

Rated Frequency: 50 Hz

Rated High Voltage: 11kV

HV Tapping Range: +7½, -5 %

Tap Switch: Off circuit

Rated Low Voltage: 415V

Tap Steps: 5 x 2½ %

Rated Current: 695.60 A

Cooling Method: ONAN

Thermal Class: A (105°C)

Coolant: Mineral Oil

Insulation Level : Li75.Ac28 / Ac3

Vector Group: Dyn11

Core Material: Aluminium

Winding Material: CRGO

Temperature Rise, Oil/Wdg: 60 / 65°C

Load Loss @ 75°C: 3900 W

No Load Loss: 459 W

Impedance: 4.75%

 

500 kVA 11kV/0.4kV Oil-Filled Electrical Distribution Transformer Technical Specs

No. Item Specification Remark
1 Power Rating 500 kVA Standard range: 100 kVA – 2500 kVA oil-immersed distribution transformers
2 Primary Voltage 11 kV (Delta) Also available: 6.6 kV, 10.5 kV, 13.2 kV, 15 kV, 22 kV
3 Secondary Voltage 0.4 kV (Wye grounded) Options: 0.415 kV, 0.33 kV, 0.208 kV based on local standards
4 Phase Three-phase Suitable for utility, commercial, and municipal grid use
5 Cooling Type ONAN (Oil Natural Air Natural) Efficient passive cooling for urban or rural installations
6 Core Material CRGO silicon steel Minimizes iron losses and improves magnetic performance
7 Insulation Fluid Electrical grade mineral oil IEEE/IEC-compliant with excellent thermal stability
8 Temperature Rise 55°C / 65°C options Compliant with North American and European requirements
9 Enclosure Type Outdoor sealed tank, IP44/IP54 Rust-resistant, anti-corrosion coating, tamper-proof design
10 Standards IEC 60076, ANSI C57, CSA, EN 50588 Meets EU & North American grid compliance standards
11 Certifications CE, UL, CSA, cUL, RoHS, ISO Third-party testing for safety and performance
12 Connection Type Delta – Wye grounded (standard) Custom configurations: Delta-Delta, Wye-Wye, etc.
13 Applications Industrial parks, data centers, local substations Widely used in Canada, UK, Germany, Spain, Portugal
14 Protection Devices Oil level gauge, pressure valve, temp gauge Optional: surge arresters, drain valve, PRV
15 Dimensions & Weight Customizable Weight ~1200–1500 kg depending on spec
16 Energy Efficiency DOE 2016 & EU Eco Design-compliant Reduces operating losses and carbon emissions
17 Installation Method Pad-mounted or pole-mounted Includes lifting lugs and skid base for transport
18 Ambient Temperature Range -25°C to +45°C Arctic-ready versions available for -40°C
19 Total Transformer Loss ≤1.6% @ full load Designed for long-term low-cost operation
20 No-Load Loss ≤ 0.3% of rated capacity Helps improve energy savings in idle conditions
21 Load Loss ≤ 1.25% of rated power Optimized for continuous load distribution
22 Impedance 5.5% typical Custom range: 5% – 7% depending on design
23 Short-Circuit Strength Withstands 25 kA for 2 sec Mechanical integrity under fault conditions
24 Insulation Class Class A (105°C) Class F or B available for higher performance
25 Windings Material Copper (standard) or Aluminum Copper preferred for lower losses and longer life
26 Tap Changer ±2 x 2.5% Off-Circuit Tap Changer OLTC available for automatic voltage adjustment
27 Bushings Porcelain per ANSI standards Polymeric bushings available for severe climates
28 Cooling Oil Volume Approx. 350–400 liters Depends on final tank size and rating
29 Transformer Lifespan 25–30 years average Designed for high-reliability utility applications
30 Noise Level ≤ 58 dB at 1 meter Urban-friendly acoustic design
31 Warranty 2 years standard Optional 5-year extended support
32 Delivery Time 30–45 days Fast delivery via sea or air freight
33 Custom Lead Time 60–75 days Tailored builds per project specs
34 Price Range Contact for quote Based on copper content, specs, and certification level
35 Country of Origin China (Energy Transformer Factory) CE/UL/CSA-certified direct manufacturing supply

11kV 500kVA Oil Immersed Transformer

500 kVA 11kV/0.4kV Oil-Filled Electrical Distribution Transformer – Factory Direct Supply

The 500 kVA electrical distribution transformer (oil-filled, 3-phase) is engineered to deliver dependable voltage conversion in commercial, industrial, and public utility environments across North America and Europe. Rated at 500 kVA, this medium voltage transformer supports reliable 11kV to 0.4kV step-down operation, ideal for low-voltage load centers in municipal grids, logistics parks, residential substations, and manufacturing plants.

 

The unit features a robust Delta-connected 11kV primary winding and grounded Wye 0.4kV secondary output. Custom voltage configurations-such as 10.5kV/415V or 12kV/400V-can be provided to meet local distribution code requirements across the United States, UK, Canada, Germany, and France. The core utilizes cold-rolled grain-oriented silicon steel for minimized core losses, while high-conductivity copper windings ensure low-temperature rise and optimized short-circuit resistance.

 

Encased in a weatherproof, hermetically sealed steel tank, the 500 kVA oil-immersed transformer is filled with degassed mineral insulating oil and designed for indoor and outdoor installation. The standard ONAN cooling system supports quiet, maintenance-friendly thermal management, with optional radiator extensions available for high ambient environments.

 

In 2022, multiple units of this 500 kVA distribution transformer were installed in a Canadian school district to modernize outdated utility substations. With smart load balancing and consistent voltage regulation during peak winter demand, they've demonstrated stable performance and improved energy efficiency under IEC and ANSI operating conditions.

 

Power Rating: 500 kVA (Typical range: 100 kVA to 2500 kVA)
Primary Voltage: 11 kV (Delta configuration, available range: 6.6 kV to 33 kV)
Secondary Voltage: 400/230 V (Wye, grounded neutral, typical LV range: 208Y/120 V to 690 V)
Connection Options: Delta–Wye (grounded), Wye–Wye, Delta–Delta, Wye–Delta (customizable per region and grid requirements)
Phase: Three-phase, 50/60 Hz compatible
Cooling Type: Oil-immersed, ONAN (natural oil and air cooling for continuous duty cycles)
Standards Compliance: IEC 60076, ANSI C57, IEEE, EN 50588-1, DOE Tier 2 compliant
Certifications: CE Marked, UL Listed, CSA Certified, ISO 9001, SGS Approved
Enclosure: Weatherproof, sealed steel tank with rust-resistant finish; designed for both pad-mount and indoor switchgear installation
Applications: Suited for commercial electrical distribution, industrial load centers, solar and wind interconnection, shopping malls, campuses, utility substations, and critical infrastructure in the US, Canada, UK, Germany, Spain, France, Netherlands, Australia, and Portugal.

500 KVA 11kV/0.4kV Oil-Filled Electrical Distribution Transformer

Introduction of Oil Immersed Transformer

oil immersed transformeroffering the choice between the Yyn0 or Dyn11 vector group configurations across a wide power range from 30 kVA to 31500 kVA. These transformers are engineered to deliver exceptional performance, efficiency, and reliability in diverse industrial and commercial settings.

 

The Yyn0 vector group configuration provides a specific phase shift angle, ensuring precise voltage regulation and stability in power distribution networks. On the other hand, the Dyn11 configuration offers an alternative phase shift angle, catering to varying operational requirements with flexibility and adaptability.

 

One of the key advantages of our transformers lies in their superior energy efficiency, reducing power losses and operational costs over the long term. With advanced design features and high-quality materials, these transformers are built to withstand demanding operating conditions and deliver consistent performance.

 

Oil-immersed transformers can be widely used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises, drilling platforms, and oil production platforms. They are especially suitable for use in places with high fire protection requirements and harsh environments such as flammable and explosive materials. They can also be used for power and lighting in residential areas, commercial streets, industrial and mining enterprises, and rural areas.

 

Product Parameter

Capacity(KVA)

No-load Loss(W)

Load Loss

Impedance Voltage(%)

No-load Current(%)

Vector Group Extend Connection
Dyn11/Yzn11 Yyno
30 100 600 630 4.0 2.1 Yyn0 OR Dyn11

±2*2.5%

Or±5%

50 130 870 910 2
63 150 1090 1040 1.9
80 180 1310 1250 1.8
100 200 1580 1500 1.6
125 240 1890 1800 1.5
160 280 2310 2200 1.4
200 340 2730 2600 1.3
250 400 3200 3050 1.2
315 480 3830 3650 1.1
400 570 4520 4300 1.0
500 680 5410 5150 1
630 810 6200 4.5 0.9
800 980 7500 0.8
1000 1150 10300 0.7
1250 1360 12000 0.6
1600 1640 14500 0.6
2000 1940 18300 5.0  
2500 2290 21200  

 

S11 35kv Three-phase Dual-winding No-load Voltage Regulation Transformer spec
Rated Capacity (KVA) Voltage Combination Connection Group Symbol No-load Loss (W) Load Loss (W) No-load Current (%) Impedance Voltage (%) L*W*H(mm) Active parts Weight (kg) * Oil Weight (kg) Total Weight (kg)
High Voltage (KV) Tapping Range of High Voltage Low Voltage (KV)
630 35 ±2×2.5% 士5% 3.15 6.3 10.5 Ydl1 830 7860 0.65 6.5 2400*1700*221 2210*900 3250
800 980 9400 0.65 2500*1850*239 2350*1030 3500
1000 1150 11500 0.65 2700*1950*251 2490*1180 3860
1250 1400 13900 0.55 2900*2050*263 2600*1350 4350
1600 1690 16600 0.45 3050*2130*275 2810*1580 4855
2000 2170 18300 0.45 3105*2195*280 2800*1800 5300
2500 2560 19600 0.45 3150*2535*298 3525*2060 7665
3150 35-38.5 ±2×2.5% 土5% 3.15 6.3 10.5 3040 23000 0.45 7 3920*2725*284 3950*2205 8565
4000 3610 27300 0.45 3310*2915*307 4825*2560 10115
5000 4320 31300 0.45 3480*3020*314 5700*2635 11305
6300 5240 35000 0.45 8 3590*2905*321 7120*3240 13510
8000 35-38.5 ±2×2.5% 3.15 3.3 6.3 6.6 10.5 Ynd11 7200 38400 0.35 4070*3050*359 8875*3840 16690
10000 8700 45300 0.35 4106*2795*365 10305*3600 17690
12500 1000 53800 0.3 4570*3010*384 12830*4310 20990
16000 1210 65800 0.3 5235*3295*461 16010*6650 27660
20000 1440 79500 0.3 5360*3415*466 18820*7600 32170
25000 1700 94000 0.25 10 5830*3810*486 22360*9800 42600
31500 2020 112000 0.25 6290*4290*526 25110*12010 49960

 

S11 35kv No-load Voltage Regulation Transformer Spec
Rated Capacity (KVA) Voltage Combination No-load Loss (W) Load Loss (W) Impedance Voltage(%) No-load Current (%) L*W*H(mm) Active parts Weight (kg) Oil Weight (kg) Total Weight (kg)
High Voltage (KV) Tapping Range of High Voltage Low Voltage (KV)
50 35 38.5 ±5% ±2×2.5% 0.4 160 1200/1140 6.5 1.3 1195*935*1825 300*330 860
100 230 2010/1910 1.1 1200*995*1935 470*383 1130
125 270 2370/2260 1.1 1235*940*1955 550*465 1335
160 280 2820/2680 1 1285*895*1950 580*485 1475
200 340 3320/3160 1 1310*1150*1985 680*595 1755
250 400 3950/3760 0.95 1450*1090*2010 860*650 2000
315 480 4750/4530 0.95 1930*1065*2320 980*765 2290
400 580 5740/5470 0.85 1850*1165*2015 1170*885 2725
500 680 6910/6580 0.85 2045*1205*2415 1340*960 3090
630 830 7860 0.65 2085*1240*2515 1550*895 3810
800 980 9400 0.65 2305*1615*2685 1990*1030 4510
1000 1150 11500 0.65 2545*1540*2590 2415*1475 5055
1250 1400 13900 0.6 2495*2010*2675 2480*1405 5290
1600 1690 16600 0.6 2680*2100*2770 2600*1490 5450
2000 1990 19700 0.55 2790*2180*2860 2720*1590 5600
2500 2360 23200 0.55 2900*2290*2980 2830*1720 5760

Drawing

product-1-1

 

product-1-1

 

product-1-1

product-682-469

Hot Tags: 11kv 500kva oil immersed transformer, China 11kv 500kva oil immersed transformer manufacturers, suppliers, factory, Single Phase Pole Mounted Oil Immersed Transformer, 2500kVA Transformer, transformer commissioning standard, S13 Transformer, transformer protection standard, transformer reactive power control