33kV Oil Immersed Distribution Transformer
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 33kv oil immersed distribution transformer in China. If you're going to buy customized 33kv oil immersed distribution transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
GNEE have some 33KV oil immersed transformer in stock, first come first served!
33KV oil-immersed distribution transformer is an important equipment in the power distribution network and the power supply and distribution system of industrial and mining enterprises. The transformer designed by GNEE adopts a leak-proof design, with the characteristics of low loss, low noise and high reliability.
oil immersed transformer offering the choice between the Yyn0 or Dyn11 vector group configurations across a wide power range from 30 kVA to 31500 kVA.
Phase: three
Cooling Method: ONAN, ONAF/ OFAF
Frequency: 50 or 60Hz
Vector Group: Dyn11, Yd11, Ynd11, or others
Capacity Range: 50KVA to 3150KVA
Primary Voltage: 30KV to 38.5KV
Coolers: corrugated wall or radiator
Oil preservation: hermetically sealed or conservator/free breathing
Tap changer: Off-circuit or On-load. 3 steps; 5 steps; 7 steps; 9 steps; 13 steps; 17 steps
Cooling medium: mineral oil
Winding materials: aluminum or copper
Parts: Oil draining valve, Oil level indicator, Thermometer, Gas relay, Pressure relief valve, Earthing terminal, Lifting lugs, Nameplate, Outdoor bushings, etc.
Rating Plate: Yes (Customer brand)
Execution Standard: IEC 60076, GB1094.1-2018
|
33KV 35KV Oil Immersed Transformer Main Technical Parameters |
||||||||||||
| Rated Capacity KVA | Voltage Combination | Connection Symbol | Off-load Loss(KW) | On-load Loss(KW) (75℃) | Impendan ce (%) | Weight(KG) | Dimensions(mm) | |||||
| High Voltage (KV) | Tapping Range (%) | Low Voltage(KV) | Oil | Total | Length | Width | Height | |||||
| 50 | 25 30 33 35 |
±5 ±2x2.5 |
0.23 0.38 0.4 0.44 0.48 0.6 |
Dyn11 Yyn0 |
0.166 | 1.285 | 6.44% | 165 | 535 | 1120 | 670 | 1235 |
| 80 | 0.209 | 1.734 | 6.66% | 195 | 670 | 1120 | 700 | 1270 | ||||
| 100 | 0.244 | 2.138 | 6.39% | 210 | 745 | 1120 | 720 | 1285 | ||||
| 125 | 0.286 | 2.552 | 6.27% | 215 | 790 | 1160 | 715 | 1330 | ||||
| 160 | 0.3 | 3.027 | 6.40% | 245 | 970 | 1245 | 785 | 1365 | ||||
| 200 | 0.361 | 3.649 | 6.28% | 360 | 1050 | 1245 | 795 | 1380 | ||||
| 250 | 0.424 | 4.294 | 6.49% | 285 | 1175 | 1335 | 880 | 1395 | ||||
| 315 | 0.51 | 5.2 | 6.31% | 310 | 1305 | 1380 | 920 | 1420 | ||||
| 400 | 0.613 | 6.171 | 6.31% | 355 | 1540 | 1510 | 1010 | 1455 | ||||
| 500 | 0.716 | 7.452 | 6.51% | 390 | 1760 | 1120 | 1105 | 1502 | ||||
| 630 | 0.897 | 8 65 | 6.60% | 430 | 2000 | 1120 | 1210 | 1527 | ||||
| 800 | 1042 | 10.181 | 6.24% | 525 | 2545 | 2080 | 1215 | 1770 | ||||
| 1000 | 1.22 | 12.375 | 6.30% | 600 | 2885 | 2125 | 1270 | 1850 | ||||
| 1250 | 1.457 | 15.119 | 6.40% | 690 | 3275 | 2150 | 1300 | 1950 | ||||
| 1600 | 1.796 | 18.337 | 6.53% | 840 | 3955 | 2310 | 1355 | 2070 | ||||
| 2000 | 2.105 | 21.122 | 6.47% | 1010 | 4775 | 2390 | 1395 | 2170 | ||||
| 2500 | 2.514 | 25.296 | 6.29% | 1145 | 5550 | 2515 | 1435 | 2300 | ||||
| S20 Oil-immersed Three-phase Double-winding No-load Voltage Regulation Power Transformers | ||||||
| Rated Capacity kVA |
Voltage Combination | No-Load Loss kW |
Load Loss(75℃) kW |
Short-circuit Impedance % |
||
| High Voltage(kV) | Tapping Range | Low Voltage (kV) | ||||
| 3150 | 33 35 38.5 |
±5% ±2×2.5% |
0.4 | 2.0 | 20.7 | 7 |
| 4000 | 2.3 | 24.6 | ||||
| 5000 | 2.8 | 28.2 | ||||
| 6300 | 3.4 | 31.5 | 8 | |||
| 8000 | 4.7 | 34.6 | ||||
| 10000 | 5.7 | 40.8 | ||||
| 12500 | 6.5 | 48.4 | ||||
| 16000 | 7.9 | 59.2 | ||||
| 20000 | 9.4 | 71.6 | ||||
| 25000 | 11.1 | 84.6 | 10 | |||
| 31500 | 13.1 | 100.8 | ||||
| S22 Oil-immersed Three-phase Double-winding No-load Voltage Regulation Power Transformers | ||||||
| Rated Capacity kVA |
Voltage Combination | No-Load Loss kW |
Load Loss(75℃) kW |
Short-circuit Impedance % |
||
| High Voltage(kV) | Tapping Range | Low Voltage (kV) | ||||
| 3150 | 33 35 38.5 |
±5% ±2×2.5% |
0.4 | 1.7 | 20.7 | 7 |
| 4000 | 2.0 | 24.6 | ||||
| 5000 | 2.4 | 28.2 | ||||
| 6300 | 2.9 | 31.5 | 8 | |||
| 8000 | 4.0 | 34.6 | ||||
| 10000 | 4.8 | 40.8 | ||||
| 12500 | 5.5 | 48.4 | ||||
| 16000 | 6.7 | 59.2 | ||||
| 20000 | 7.9 | 71.6 | ||||
| 25000 | 9.4 | 84.6 | 10 | |||
| 31500 | 11.1 | 100.8 | ||||
The core is made of high-quality, high-performance silicon steel sheets, with low no-load loss.
The high-voltage winding adopts a layered structure, with high mechanical strength, balanced distribution, and strong short-circuit resistance.
The overall structure is fully sealed, and the vacuum oil filling process is adopted to ensure that the transformer oil is isolated from the outside air, prevent oil aging, and improve the reliability of transformer operation.
The corrugated oil tank is used, which is simple to process, has high mechanical strength, good welding effect, no leakage, and good heat dissipation capacity.
It has beautiful appearance and small size, and is widely used in urban and rural power grids.

Here are our customer examples for your reference
Chile clients
Data sheet N° 2-A: Transformer H61 33 kV/400V of 160 kVA
|
DESIGNATIONS |
S UNITS |
SPECIFIC DATA |
|
Maker |
To be indicated |
|
|
Reference standard |
IEC 60076 |
|
|
Type |
Phase |
|
|
Vat |
Hermetic |
|
|
Execution |
Tropicalized |
|
|
Dielectric |
PCB-free oil |
|
|
Installation |
On pole |
|
|
Operating ambient temperature |
°C |
45 |
|
Rated frequency |
Hz |
50 |
|
Rated power |
Kva |
160 |
|
Rated primary voltage |
Kv |
33 |
|
Isolation level assigned to primary school |
Kv |
36 |
|
Number of phases in primary school |
03 |
|
|
Secondary voltage |
V |
400/230 |
|
Voltage adjustment range on the M side when unladen |
% |
±2.5 |
|
Coupling |
Yzn11 |
|
|
Short circuit voltage |
% |
4 - 4.5 |
|
Neutral sized for one load |
% |
100 |
|
Maximum vacuum losses |
W |
230 – 460 |
|
Losses due to Maxi load |
W |
1450 - 2350 |
|
Maximum steady-state oil temperature |
°C |
55 |
|
Maximum temperature of the windings in steady state |
°C |
60 |
|
Winding material |
Electrolytic copper |
|
|
Maximum noise level |
Db |
52 |
|
50Hz industrial frequency hold, 1 min |
Kv |
50 - 70 |
|
Shock wave resistance (1.2/50 micros) |
Kv |
125 - 170 |
|
Cooling |
ONAN |
|
|
Nameplate |
01 |
|
|
Grounding connection |
01 |
|
|
Dimensions Height/width/depth |
mm x mm x mm |
1200 X 1050 X 710 |
|
Total mass of transformer including oil |
Kg |
400 |
|
Oil mass |
Kg |
90 |
|
PAINT |
||
|
Tropicalized and anti-rust |
||
|
Layers |
||
|
Binder |
||
|
Colour |
||
|
Plans and technical diagrams to be provided. |
||
Hot Tags: 33kv oil immersed distribution transformer, China 33kv oil immersed distribution transformer manufacturers, suppliers, factory, transformer oil leak detection, transformer inspection standard, transformer rust prevention, transformer efficiency standard, Oil Insulated Current Transformers, transformer safety regulation