Three-phase pad mounted transformer
Oil-filled (non-PCB mineral oil)
Enclosure type:stainless outdoor enclosure
Enclosure color:Munsell green
Primary:13800Delta
Secondary:480Y/277V wye
No-load loss:5684W
Load Loss:21472W
ANSI/IEEE Standard
With UL Listed
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
introduction of Dead front loop feed pad mounted transformer

Three-phase pad mounted transformer is a special type of power transformer that has been improved on the basis of ordinary oil immersed transformers by combining various auxiliary equipment such as plug-in fuses, backup fuses, tap changers, circuit load switches, low-voltage distribution devices, etc. Three-phase pad-mounted compartmental type transformers are widely used in residential and commercial power distribution, especially in underground systems.
features
Striking design: The Dead Front Combined Transformer Substation is a robust and stylish product that impresses with its sharp, simple design. It is ideal for both commercial and residential areas and provides a modern look to your space.
Dual voltage rating: Equipped with a 220/240V dual voltage system, the Dead Front Combined Transformer Substation offers flexibility in power usage, ensuring compatibility with a wide range of devices and appliances.
Outdoor-rated: This outdoor-rated product is built to withstand harsh weather conditions, making it perfect for areas subject to heavy rainfall, winds, and other environmental factors.
Plug and play: The Dead Front Combined Transformer Substation is designed for ease of use, with a simple plug-and-play installation process. Users can quickly set up and enjoy a stable and efficient power supply.
Premium materials: Made from high-quality materials such as copper and aluminum, this pad-mounted compartmental type transformer is not only durable but also efficient in power transfer. Its oil-filled design offers optimal cooling and reduces noise, enhancing the overall user experience.
Key attributes
Frequency |
50/60Hz |
Phase |
Three |
Output Voltage |
480/277V |
Input Voltage |
13200V, 13800V |
Place of Origin |
Henan, China |
Model Number |
ZGS |
Coil Number |
2 winding |
application |
Power,Mining |
Coil Structure |
TOROIDAL |
Type |
Oil-Immersed Transformer,Loop Feed |
Product name |
Pad mounted transformer |
Rated capacity |
10KVA-50000KVA |
Windings material |
Copper |
Primary voltage |
34.5/24.94/13.8/13.2/12.47kv |
Secondary voltage |
0.4kV /0.415kV |
Tachnical Data for Three Phase Pad Mounted Transformer |
||||||
Rated Power (KVA) |
Loss (W) |
Dimension(mm) |
Weight(kg) |
|||
No-load Loss (W) |
On-load Loss (W) |
W |
D |
H |
||
75KVA |
180 |
1250 |
1390 |
910 |
1430 |
645 |
150KVA |
280 |
2200 |
1510 |
980 |
1530 |
989 |
300KVA |
480 |
3650 |
1660 |
1080 |
1680 |
1415 |
500KVA |
680 |
5100 |
1810 |
1160 |
1790 |
1905 |
750KVA |
980 |
7500 |
2030 |
1300 |
2030 |
2755 |
1000KVA |
1150 |
10300 |
1651 |
1549 |
1854 |
3235 |
1500KVA |
1640 |
14500 |
2210 |
1470 |
2150 |
5835 |
2000KVA |
2160 |
20645 |
2380 |
1600 |
2220 |
6430 |
2500KVA |
2680 |
27786 |
3070 |
1650 |
2330 |
8865 |
3000KVA |
3300 |
30300 |
3260 |
1850 |
2460 |
11300 |
3750KVA |
4125 |
37875 |
4080 |
2060 |
2680 |
14400 |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
When choosing our company's products, please provide the following data to better serve you. |
||
Demander |
||
Demander: |
Telephonemethods: |
Fax: |
Project technical leader: |
Telephonemethods: |
Mailbox: |
Transformer type selection |
||
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
Transformer basic data selection
Country of use: |
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: Three-phase pad mounted transformer, China Three-phase pad mounted transformer manufacturers, suppliers, factory, 75kVA Single Phase Pad Mount Transformer, decision of pad mounted transformer, pad mounted residential transformer, pad mounted transformer core, pad mounted transformer installation guide, regulations for pad mounted transformer
You Might Also Like
Send Inquiry