Dead Front Loop Feed Pad Mounted Transformer
Oil-filled (non-PCB mineral oil)
Enclosure type:stainless outdoor enclosure
Enclosure color:Munsell green
Primary:13800Delta
Secondary:480Y/277V wye
No-load loss:5684W
Load Loss:21472W
ANSI/IEEE Standard
With UL Listed
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
introduction of Dead front loop feed pad mounted transformer

Dead front loop feed pad mounted transformers provide users with many benefits, saving a lot of energy for owners and bringing environmental benefits. Higher efficiency not only extends the lifespan of pad mounted transformers, but also saves costs for owners in the form of lower energy bills and reduced ownership costs.
advantages
- Safe and reliable: By adopting efficient insulation protection and heat dissipation equipment, the structure of the cable cabinet is reasonable, which can effectively ensure the safety and reliability of power equipment.
- Strong overload capacity: allows overload without affecting the service life of the pad mounted transformer.
- Adopting elbow type plug: It is very convenient to connect high-voltage incoming cables and can be plugged and unplugged with electricity.
- Strong defense capability: Pad type transformers have strong defense capabilities and can effectively resist transient voltage peaks in power equipment, protecting the equipment from damage.
- Longevity: Made of high-quality materials and high-tech production processes, it is durable and has a higher service life. Its overall service life is higher than that of ordinary oil immersed transformers.
- Energy conservation and environmental protection: In the design and use of pad mounted transformers, emphasis is placed on energy conservation and environmental protection, which can ensure not only high energy efficiency but also reduce energy waste and environmental pollution.
application
Dead front loop feed pad mounted transformer is widely used in places with high electricity consumption such as factories and commercial complexes. It can convert high voltage electricity into low voltage electricity suitable for equipment use, and its capacity design precisely balances efficiency and economy. It will not cause overload due to too small capacity, nor waste resources due to too large capacity.
Key attributes of three-phase Dead front loop feed pad mounted transformer
|
Frequency |
50/60Hz |
Phase |
Three |
|
Output Voltage |
480/277V |
Input Voltage |
13200V, 13800V |
|
Place of Origin |
Henan, China |
Model Number |
ZGS |
|
Coil Number |
2 winding |
application |
Power, Mining |
|
Coil Structure |
TOROIDAL |
Type |
Oil-Immersed Transformer, Loop Feed |
|
Product name |
Pad mounted transformer |
Rated capacity |
10KVA-50000KVA |
|
Windings material |
Copper |
Primary voltage |
34.5/24.94/13.8/13.2/12.47kv |
|
Secondary voltage |
0.4kV /0.415kV |
|
Tachnical Data for Three Phase Pad Mounted Transformer |
||||||
|
Rated Power (KVA) |
Loss (W) |
Dimension(mm) |
Weight(kg) |
|||
|
No-load Loss (W) |
On-load Loss (W) |
W |
D |
H |
||
|
75KVA |
180 |
1250 |
1390 |
910 |
1430 |
645 |
|
150KVA |
280 |
2200 |
1510 |
980 |
1530 |
989 |
|
300KVA |
480 |
3650 |
1660 |
1080 |
1680 |
1415 |
|
500KVA |
680 |
5100 |
1810 |
1160 |
1790 |
1905 |
|
750KVA |
980 |
7500 |
2030 |
1300 |
2030 |
2755 |
|
1000KVA |
1150 |
10300 |
1651 |
1549 |
1854 |
3235 |
|
1500KVA |
1640 |
14500 |
2210 |
1470 |
2150 |
5835 |
|
2000KVA |
2160 |
20645 |
2380 |
1600 |
2220 |
6430 |
|
2500KVA |
2680 |
27786 |
3070 |
1650 |
2330 |
8865 |
|
3000KVA |
3300 |
30300 |
3260 |
1850 |
2460 |
11300 |
|
3750KVA |
4125 |
37875 |
4080 |
2060 |
2680 |
14400 |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: dead front loop feed pad mounted transformer, China dead front loop feed pad mounted transformer manufacturers, suppliers, factory, 3 Phase Pad Mounted Transformer, buying guide for pad mounted transformer, pad mounted transformer bushings, pad mounted transformer windings, radiator of pad mounted transformer, warranty of pad mounted transformer
You Might Also Like
Send Inquiry