
10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
Products with high efficiency, low loss,low noise characteristics;
Internal heat dissipation is good, anti-short circuit ability;
Empty, low load loss;
Reliable operation, long life, maintenance-free.
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
introduction of 10kV double-winding power transformer
GNEE TRANSFORMER supplies 10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer.
10KV oil-immersed distribution transformers are important equipment in the distribution network and power supply and distribution systems of industrial & mining enterpises. It has the advantages of compact structure, beautiful appearance,small size,low noise,and strong overload capaity.
10KV class three phase oi-immersed distribution transformer has hermetially sealed type and conservator type, The transformer is applicable to plant, mine,petrol chemical and other power distrbution system of 10KV class for industy and agriculture. They are also popular in sites with oil contamination and chemical substances.
10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer | ||||||||
Rated | Rated voltage and tapping range | Vector | No Load | Impedance | No load | On load | ||
capacity | group | Current | voltage | Losses | Losses | |||
(kVA) | HV | Tapping range | LV | (%) | (%) | (kW) | (kW) | |
200 |
6 6.3 10 10.5 |
±4x2.5 | 0.4 |
Dyn11 Yyn0 |
0.8 | 4 | 0.31 | 2.9 |
250 | 0.72 | 0.35 | 3.42 | |||||
315 | 0.72 | 0.43 | 4.1 | |||||
400 | 0.64 | 0.51 | 4.95 | |||||
500 | 0.64 | 0.61 | 5.89 | |||||
630 | 0.48 | 4.5 | 0.77 | 7.26 | ||||
800 | 0.48 | 0.9 | 8.89 | |||||
1000 | 0.48 | 1.09 | 10.4 | |||||
1250 | 0.4 | 1.25 | 12.3 | |||||
1600 | 0.4 | 1.54 | 14.7 | |||||
2000 | 0.32 | 5 | 1.82 | 18.6 | ||||
2500 | 0.32 | 2.14 | 21.6 |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
When choosing our company's products, please provide the following data to better serve you. |
||
Demander |
||
Demander: |
Telephonemethods: |
Fax: |
Project technical leader: |
Telephonemethods: |
Mailbox: |
Transformer type selection |
||
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
Transformer basic data selection
Country of use: |
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: 10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer, China 10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer manufacturers, suppliers, factory, 150kVA Oil Immersed Distribution Transformer, 75kVA Oil Immersed Distribution Transformers, Single Phase Oil Immersed Power Transformer, Single Phase Oil Immersed Transformer, Single Phase Pole Mounted Oil Immersed Transformer, Three Phase Oil Immersed Distribution Transformer
You Might Also Like
Send Inquiry