
SG(B)12~18 non-encapsulated H-class dry type transformer
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
introduction of SG(B)12~18 dry type transformer
GNEE TRANSFORMER supplies SG(B)12~18 non-encapsulated H-class dry type transformer.
SGB series non-encapsulated H-class dry-type transformer adopts the special process technology of (Germany) MORA dry-type transformer, so that the product can fully meet the requirements of fireproof, waterproof and environmental protection. It is an ideal product for power distribution system, and is widely used in subways, ships, mines, chemical industries, power enterprises and densely populated buildings and other occasions with special require- ments for safety and fire protection.
Features:
- High – Temperature Resistance
The H – class insulation enables these transformers to operate in high – temperature environments without significant degradation of performance. This is crucial in applications where ambient temperatures may be elevated, such as in industrial settings with large amounts of heat – generating equipment or in areas with hot climates. For example, in a steel mill, where the operating temperature can be quite high, the SG(B) H – class dry transformer can maintain stable power conversion.
- Fire – Resistant and Environmentally Friendly
The use of non – combustible H – class insulation materials makes these transformers highly fire – resistant. This reduces the risk of fire hazards in case of electrical malfunctions, enhancing safety in various installations. Additionally, since they do not use oil as a coolant like some traditional transformers, there is no risk of oil leakage, which is more environmentally friendly. They are suitable for installation in areas where environmental protection is a priority, such as near water bodies or in densely populated urban areas.
- Low Noise Operation
SG(B) packageless H – class dry transformers are designed to operate with low noise levels. The optimized core design and winding technology reduce the mechanical vibrations and electromagnetic noises that are common in transformers. This makes them ideal for applications where noise pollution needs to be minimized, such as in hospitals, schools, and residential areas.
- High Efficiency
With advanced design and high – quality materials, these transformers achieve high energy efficiency. The low – loss core and well – designed windings result in reduced power losses during operation. This not only saves energy but also helps in reducing operating costs for users. In commercial buildings with large power demands, the high – efficiency operation of SG(B) H – class dry transformers can lead to significant savings in electricity bills over time.
10kV Class SGB12 Product Data | ||||||||||
Rated High Voltage:10kV ,5kV Connection Symbol:Dyn11/Yyn0 | ||||||||||
Nominal Low-voltage:0.4kV Tapping Range:±2×2.5% | ||||||||||
Model No. | UK % | Air loss PO(W) | Load loss ( 75ºC) PK(W) |
IO ( %) |
LPA (AN ) dB | SIZE L*B*H(mm) |
installation size m*n(mm) | Body size (including feet) |
Outer packing size (including sole) | Weight with outer packaging(kg) |
SGB12-315 | 4% | 705 | 3340 | 1.0 | 46 | 1320×860×1230 | 660×660 | 1900×1300×1660 | 1900×1300×2200 | 340 |
SGB12-400 | 4% | 785 | 3870 | 1.0 | 46 | 1340×860×1410 | 820×660 | 1900×1300×1660 | 1900×1300×2200 | 340 |
SGB12-500 | 4% | 930 | 4720 | 1.0 | 47 | 1350×860×1430 | 820×660 | 1900×1300×1660 | 1900×1300×2200 | 340 |
SGB12-630 | 6% | 1040 | 5760 | 0.8 | 49 | 1400×860×1440 | 820×660 | 2100×1400×2015 | 2100×1400×2200 | 400 |
SGB12-800 | 6% | 1215 | 6740 | 0.8 | 50 | 1450×1020×1450 | 820×820 | 2100×1400×2015 | 2100×1400×2200 | 400 |
SGB12-800 | 6% | 1415 | 7850 | 0.8 | 50 | 1520×1020×1540 | 820×820 | 2100×1400×2015 | 2100×1400×2200 | 400 |
SGB12-1250 | 6% | 1670 | 9480 | 0.8 | 51 | 1600×1020×1740 | 820×820 | 2300×1500×2120 | 2300×1500×2200 | 450 |
SGB12-1600 | 6% | 1960 | 11410 | 0.8 | 52 | 1800×1150×1790 | 1070×1070 | 2300×1500×2120 | 2300×1500×2200 | 500 |
SGB12-2000 | 6% | 2440 | 14000 | 0.6 | 52 | 1810×1150×1840 | 1070×1070 | 2400×1500×2300 | 2400×1500×2300 | 500 |
SGB12-2500 | 6% | 2880 | 16670 | 0.6 | 53 | 1900×1150×1960 | 1070×1070 | 2600×1500×2500 | 2600×1500×2500 | 500 |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
When choosing our company's products, please provide the following data to better serve you. |
||
Demander |
||
Demander: |
Telephonemethods: |
Fax: |
Project technical leader: |
Telephonemethods: |
Mailbox: |
Transformer type selection |
||
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
Transformer basic data selection
Country of use: |
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: SG(B)12~18 non-encapsulated H-class dry type transformer, China SG(B)12~18 non-encapsulated H-class dry type transformer manufacturers, suppliers, factory, 1500 kva dry type transformer, dry type power transformers, indoor dry type transformer, Low Voltage Dry Type Distribution Transformers, Single Phase Dry Type Transformer, Three Phase Dry Type Distribution Transformer
You Might Also Like
Send Inquiry