
220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
introduction of 220kV three-phase power transformer
GNEE TRANSFORMER supplies 220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer.
The 220kV transformer is a high-voltage oil-immersed transformer with a core-type structure. It can be classified by phase number into single-phase transformers and three-phase transformers; by voltage regulation method into on-load tap-changing transformers and no-load tap-changing transformers; by winding coupling method into power transformers and autotransformers; by the number of windings into double-winding, three-winding, and three-winding plus balance winding transformers. Additionally, it includes special types such as split transformers and combined transformers. The product is designed according to IEC international standards, IEEE standards, and current national standards.
Main Features:
- Low Noise: Reduces noise pollution to the environment.
- Low Partial Discharge: Ensures stable and reliable transformer operation.
- Low Temperature Rise: Provides strong overload capacity.
- Low Loss: Optimizes energy structure.
- Leakage-Free: Ensures high sealing performance of the transformer.
- Maintenance-Free: Reduces customer maintenance costs.
- High Impedance: Offers high short-circuit resistance, providing transformer safety.
- Smart Components: Incorporates intelligent substation design technology.
220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer | ||||||||
Rated | Rated voltage and tapping range |
Vector group |
No Load | Short-circuit | No load | On load | ||
capacity | Current | impedance | Losses | Losses | ||||
(kVA) | HV | Tapping range | LV | (%) | (%) | (kW) | (kw) | |
31500 |
220 242 |
±2x2.5 |
6.3 6.6 |
YNd 11 | 0.45 | 12~14 | 15 | 115 |
40000 | 0.45 | 18 | 134 | |||||
50000 | 0.42 | 21 | 161 | |||||
63000 | 0.42 | 25 | 188 | |||||
75000 |
10.5 13.8 |
0.38 | 29 | 213 | ||||
90000 | 0.35 | 34 | 246 | |||||
120000 | 0.35 | 41 | 304 | |||||
150000 |
10.5 13.8 |
0.32 | 49 | 360 | ||||
160000 | 0.31 | 51 | 378 | |||||
180000 | 0.29 | 56 | 413 | |||||
240000 | 0.26 | 70 | 484 |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
When choosing our company's products, please provide the following data to better serve you. |
||
Demander |
||
Demander: |
Telephonemethods: |
Fax: |
Project technical leader: |
Telephonemethods: |
Mailbox: |
Transformer type selection |
||
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
Transformer basic data selection
Country of use: |
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: 220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer, China 220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer manufacturers, suppliers, factory, 11kV Three Phase Oil Immersed Distribution Transformer, 75kVA Oil Immersed Distribution Transformers, Oil Immersed Dead Tank Current Transformer, Oil Immersed Power Transformer, Oil Immersed Transformer, Single Phase Pole Mounted Oil Immersed Transformer
You Might Also Like
Send Inquiry