introduction of QSG/SG three-phase dry isolation transformer
GNEE TRANSFORMER supplies QSG/SG three-phase dry isolation transformer.
QSG/SG three-phase dry-type isolation transformer is a new generation of energy-saving power transformer, from 300VA to 1600KVA, in line with IEC439, GB5226 and other international and national standards, and the winding adopts the whole winding method; The transformer is vacuum-impregnated, so that the insulation grade of the transformer reaches F or H, and the product performance reaches the advanced level at home and abroad. QSG/SG series three-phase dry-type isolation transformers are widely used in AC 50Hz to 60Hz, voltage below 2000V circuits, widely used in imported important equipment, precision machine tools, mechanical and electronic equipment, medical equipment, rectifier devices, lighting, etc.
Advantages
- Safe & Eco-Friendly - No flammable oil, reducing fire and environmental risks.
- High Efficiency - Low energy loss with advanced core materials.
- Reliable & Durable - Resists moisture, dust, and corrosion for long service life.
- Low Maintenance - No oil checks; minimal upkeep required.
- Flexible Installation - Compact, lightweight, and suitable for indoor/outdoor use.
- Clean Power - Reduces electrical noise and stabilizes voltage for sensitive equipment.
- Ideal for industrial, commercial, and renewable energy applications.
Product specifications
Model | QSG/SG |
Phase | Three phase |
Overload Capacity | ±1% |
Voltage Change Rate | ≤1.5% |
Distortion Of Output Waveform | No distortion(compared toinput waveform) |
Insulation Class | Class F,high temperature resistance 150℃ |
Insulation Resistance | ≥150MQ |
Work Efficiency | Inductive (isolated)>99% |
Dielectric Strength | 2000VA/1min |
Overload Capacity | lt is allowed to exceed 1.2 times ofrated load |
Design Life | 30 years |
Noise | ≤35dB (within one meter) |
Cooling Method | Dryair cooling |
Temperare Rise | ≤60°C |
Frequency | 50/60Hz |
Working Environment | Temperature:-20~+45°C Humidity:≤95% RH does not condense |
Workplace | Non-corrosive gas and conductive dust |
Connection Method | Anycombination of Y/△ |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
When choosing our company's products, please provide the following data to better serve you. |
||
Demander |
||
Demander: |
Telephonemethods: |
Fax: |
Project technical leader: |
Telephonemethods: |
Mailbox: |
Transformer type selection |
||
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
Transformer basic data selection
Country of use: |
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: qsg/sg three-phase dry isolation transformer, China qsg/sg three-phase dry isolation transformer manufacturers, suppliers, factory, 1500 kva dry type transformer, Cast Resin Dry Type Transformer, Dry Transformer, Dry Type Distribution Transformers, Three Phase Dry Type Distribution Transformer, three phase dry type transformers
You Might Also Like
Send Inquiry