100KVA American Type Substation Compact Substation

100KVA American Type Substation Compact Substation

Product Name: 100KVA American Type Substation Compact Substation
Capacity: 100KVA
Delivery Year: 2021
Country: Mexico
Key Advantages:
Space-saving Design: The American Type Compact Substation integrates the Substation Transformer and switching equipment into a single modular unit, reducing floor space by 50% compared to traditional substations.
Rapid Installation: The pre-configured Compact Substation allows for quick deployment in Mexico’s expanding urban infrastructure projects.
High Reliability: Designed to meet American Type Substation standards, it ensures stable power distribution even under fluctuating loads.
Send Inquiry
Chat Now

Have questions? GNEE sales representatives are available for live chat now

Send E-mail: sales@gneeelectric.com

Tel: +8615824687445

 

Advantages of Compact Substation vs. Traditional Transformers

 

 

The Compact Substation offers distinct advantages over conventional Substation Transformers:

 

Space Efficiency:

Unlike bulky open-type transformers, the American Type Compact Substation combines the Substation Transformer, circuit breakers, and protective devices into a compact, sealed unit, reducing physical footprint by up to 60%.

Modular and Plug-and-Play:

The Compact Substation is pre-assembled and tested, enabling faster installation (within days vs. weeks) compared to assembling individual components. This is critical for American Type Substation applications in urgent utility projects.

Enhanced Safety and Maintenance:

The Compact Substation's sealed design prevents environmental contaminants from affecting the Substation Transformer, extending lifespan.

Built-in monitoring systems simplify real-time diagnostics, while the American Type Substation's standardized interfaces ensure easy access for maintenance.

Cost Savings:

Lower labor and site preparation costs due to the Compact Substation's compactness, combined with reduced downtime from its robust Substation Transformer core.

 

100KVA American Type Substation Compact Substation

 

 

 

Products parameter

 

 

 

No Item Unit Technical Parameters
1 Rated Voltage KV 10/0.4(HV/LV)
2 Maximum Working Voltage KV 12(High voltage side)
3 Rated Frequency Hz 50
4 Rated Capacity KVA 50-1600
5 1Min Working Frequency Withstand Voltage KV 35
6 Lightning Impulse Voltage KV 75
7 Cooling Mode   ONAN
8 High Voltage Backup Fuse Breaking Current KA 50
9 Breaking Current Of Plug-in Fuse KA 2.5
10 Ambient Temperature ºC -35~+40
11 Coil Allows Temperature Rise ºC 65
12 No Load Voltage Regulation   ±5% or ±2×2.5%
13 Noise Level db 50
14 Class Of Protection   IP43

 

100KVA American Type Substation Compact Substation

 

 

Contact now

 

 

 

Maintenance Guidelines

 

To ensure optimal performance of the American Type Compact Substation, follow these guidelines:

 

Regular Inspections:

Check the Substation Transformer's oil level and pressure monthly. Low oil may indicate leaks, compromising insulation.

Inspect the Compact Substation's cabinet for corrosion or damage, especially in high-humidity environments.

Temperature Monitoring:

Use infrared thermometers to scan the Substation Transformer's coils and bushings quarterly. Abnormally high temperatures signal potential overload or winding issues.

Cleaning and Ventilation:

Clean the Compact Substation's ventilation grilles every six months to prevent dust buildup, which can reduce cooling efficiency.

Preventive Testing:

Conduct annual tests on the American Type Substation's insulation resistance and transformer tap changers to detect early faults.

Perform load tests during peak seasons to ensure the Substation Transformer meets 100KVA capacity demands.

Documentation:

Record all maintenance activities in the provided logbook. This aids troubleshooting and compliance with Compact Substation warranty terms.

 

100KVA American Type Substation Compact Substation

 

 

Why choose us?

 

GNEE strictly follows the comprehensive acceptance testing process to ensure that the performance of each device meets the standards. Our products and services have been successfully applied in more than 50 countries and regions around the world. As a trusted global industrial partner, we are always committed to helping customers achieve their sustainable development vision through high-quality products and full-process services.

Support
• Pre-sales: Free technical consulting, drawing review, and installation training.
• After-sales:
o Global warranty for 2 years; 5-year warranty on core components.
o 7×24-hour remote support, fault response within <24 hours.
o Operation manual provided.

 

Production environment

100KVA American Type Substation Compact Substation

 

Packing and Delivery

100KVA American Type Substation Compact Substation

 

SGS certification certificate

100KVA American Type Substation Compact Substation

 

FAQ
 

Q1: How to Choose Between Oil-Immersed, Dry-Type, or Amorphous Alloy Transformers Based on Needs?

A:Oil-immersed transformers (e.g., 30-2500 kVA/10 kV Oil-Immersed Three-Phase Dual-Winding):
Applicable scenarios: Large factories, substations, outdoor high-voltage power distribution.
Advantages: Excellent heat dissipation for high loads and high-temperature environments, but requires fire prevention and oil leakage precautions.
Dry-type transformers (e.g., Epoxy resin-cast type, Dry-Type Dual-Winding):
Applicable scenarios: Indoor installations (e.g., data centers, commercial buildings), environments with strict fire safety requirements.
Advantages: No insulation oil, pollution-free, low noise, but requires ventilation for heat dissipation.
Amorphous alloy transformers (e.g., Amorphous Alloy Dry-Type):
Applicable scenarios: Grid-end applications, rural power supply, energy-efficient systems.
Advantages: Reduces no-load loss by over 70%, higher efficiency than traditional transformers, ideal for long-term low-load operations.

Q2: Which Equipment is Suitable for Rectifier Transformers (30-3200 kVA Rectifier Type)?

A: Designed specifically for rectifier equipment, such as:
Electroplating lines, electrolytic cells.
Aluminum/copper electrolysis production.
DC motor drive systems.
Features: Three-phase input, adjustable DC voltage output. Note: Harmonic loads may impact transformer performance.

Q3: What are the Differences Between Prefabricated Substations (European Style) and Combined Transformers (Combined Type)?

A:Prefabricated Substations:
High integration: Includes transformers, low-voltage cabinets, and protection devices pre-installed in weatherproof/fire-resistant enclosures.
Applicable scenarios: Rapidly deployable outdoor power systems (e.g., temporary construction sites, remote areas).
Combined Transformers:
Functional integration: Typically combines transformers, metering devices, and protection equipment to simplify power distribution.
Applicable scenarios: Power distribution hubs for small/medium factories or commercial complexes.

Q4: What is the Voltage Adjustment Method for 30-2500 kVA Dual-Winding Non-Adjustable Voltage Transformers?

A:Non-adjustable type: Fixed output voltage set at factory (e.g., 10 kV input → 400 V output); no on-site adjustment.
Applicable scenarios: Stable voltage environments with minimal load fluctuations (e.g., fixed production lines).
For voltage adjustment, choose on-load tap-changing transformers (customizable).

Q5: What are the Temperature Resistance and Lifespan of Epoxy Resin-Cast Dry-Type Transformers?

A:Temperature resistance: Class F (155°C) or Class H (180°C), with overload capacity up to 1.5× rated power.
Lifespan: Over 20 years under normal operation, but requires regular inspections of winding insulation and cooling systems.

 

Contact now

 

 

Hot Tags: 100kva american type substation compact substation, China 100kva american type substation compact substation manufacturers, suppliers, factory, 33kv compact substation, Mini Substation Transformer, Dry Type Secondary Substation Transformers, Dry Type Transformer Unitized Substation, secondary unit substation transformer, substation transformer recommendation

Send Inquiry