Power substations are an essential component of the electrical power grid. They play a crucial role in ensuring that electricity is distributed safely and efficiently to homes, businesses, and industries. A power substation typically consists of several pieces of equipment, including transformers, circuit breakers, switches, and other devices that help to control and protect the flow of electricity.
The main difference we find between substations and power substations is the scale of the installation. While substations are connected to the high/medium voltage transmission system, electricity substations are designed to support and transform lower voltages.
|
Description |
Unit |
Three Phase Power Substation |
|
Catalog No. |
NA |
25000kVA/354kV |
|
Insulation Type |
NA |
Oil |
|
Cooling Method |
NA |
ONAN |
|
Coil Configuration |
NA |
2 Winding |
|
Rating |
kVA |
25000 |
|
Vector Group |
NA |
Yd11, YNd11 |
|
Tapping Range |
% |
±4×2.5 |
|
Primary Voltage |
kV |
30/33/35 |
|
Secondary Voltage |
kV |
10/11 |
|
No-load loss |
kW |
19.12 |
|
Load-loss(75℃) |
kW |
93.5 |
|
Impedance |
% |
8.0 |
|
Short circuit current |
% |
0.3 |
|
Primary Insulation Level |
kV |
LI170 AC70 |
|
Secondary Insulation Level |
kV |
LI75 AC28 |
|
Temperature rise |
||
|
Oil |
℃ |
60℃ |
| Windings | ℃ | 65℃ |
Parts of an Power substation
Transformer: It is a static electrical machine that serves to increase or decrease electricity in an AC electrical circuit, while maintaining a constant frequency and power.
Circuit breaker: It interrupts and reestablishes the continuity of an electric circuit. Such interruption is made with load or short-circuit current.
Recloser: It is an electromechanical part that interrupts the current when there is an excess of electricity and acts when a fault is generated in the circuit. Reclosers are designed to operate with 3 closing operations and 4 openings with an interval between them.
Blade fuses: They are connection and disconnection elements of electric circuits with a double function. On the one hand, as a blade disconnect, it switches on and off. On the other hand, it acts as a fuse protection element and is used when an overcurrent is registered.
Disconnect switches and test switches: They serve to physically disconnect an electric circuit, so they usually operate without charge. These switches work mechanically and also manually.
Lightning arresters: They are responsible for keeping ionized rays away. When there is a surge of a certain magnitude, lightning arresters form an electronic arc that makes the current discharge on the ground and not on people or equipment and installations.
Instrument transformers: They are apparatuses responsible for measuring the electric current. There are two types: current transformers (CT), to change the value of the current, and potential transformers (PT), to transform the voltage values without taking the current into account. Both values are used in real time for measuring, control, and protection instruments that require current or voltage signals.
Junction boxes: They are the connection terminals per phase that allow us to make derivations and to reach specific areas.
Condensers: They allow us to conserve the electricity that is produced in an electric field. Through two conductors separated by insulating material, energy is temporarily stored.

Types of electrical substations
Transformer substation
They have one or several transformers that raise or reduce the voltage. And they may be:
- Step-up transformer substations: The voltage generated is raised to some much higher levels to be able to transport it. Normally, this installation is located outside, very close to electricity-generating plants.
- Step-down transformer substations: Unlike step-ups, these electrical substations reduce high voltages to medium levels for distribution.
Switching substation
In this type of electrical substation, two or more circuits are connected. The voltage isn't raised or lowered, but it serves as a node in the electrical system.