What is the turn - ratio test for dry type transformers?

Jun 25, 2025

Leave a message

The turn - ratio test is a crucial diagnostic procedure for dry - type transformers, which are widely used in various electrical power systems. As a dry - type transformer supplier, I have witnessed firsthand the significance of this test in ensuring the proper functioning and reliability of these transformers.

Understanding the Basics of Transformer Turn - Ratio

Before delving into the turn - ratio test, it's essential to understand what the turn - ratio of a transformer is. A transformer consists of primary and secondary windings. The turn - ratio (N) is defined as the ratio of the number of turns in the primary winding (Np) to the number of turns in the secondary winding (Ns), i.e., N = Np/Ns. This ratio plays a fundamental role in determining the voltage transformation characteristics of the transformer. According to the principle of electromagnetic induction, the ratio of the primary voltage (Vp) to the secondary voltage (Vs) is approximately equal to the turn - ratio, assuming an ideal transformer (Vp/Vs ≈ Np/Ns).

Why is the Turn - Ratio Test Necessary?

  1. Ensuring Design Compliance
    During the manufacturing process, transformers are designed with specific turn - ratios to meet the required voltage transformation specifications. A turn - ratio test verifies that the actual turn - ratio of the manufactured transformer matches the design value. Any deviation from the design turn - ratio can lead to incorrect voltage output, which may cause malfunctions in the connected electrical equipment. For example, if a transformer is designed to step down the voltage from 10kV to 400V but has an incorrect turn - ratio, the secondary voltage may be either too high or too low, endangering the safety and performance of the load.
  2. Detecting Winding Faults
    The turn - ratio test can also help in detecting various winding faults. Short - circuits between turns in either the primary or secondary winding can change the effective number of turns, thereby altering the turn - ratio. An open - circuit in the winding can also disrupt the normal magnetic coupling between the windings and affect the turn - ratio. By regularly performing turn - ratio tests, these faults can be detected early, allowing for timely maintenance and preventing more severe damage to the transformer.
  3. Assessing Transformer Health
    Over time, factors such as electrical stress, thermal cycling, and mechanical vibrations can cause changes in the winding characteristics of a transformer. Monitoring the turn - ratio over its service life provides valuable information about the overall health of the transformer. A gradual change in the turn - ratio may indicate the onset of degradation, which can help in planning for preventive maintenance or replacement.

The Procedure of the Turn - Ratio Test

  1. Test Setup
    To perform a turn - ratio test, a turn - ratio tester is required. The tester is typically connected to the primary and secondary terminals of the transformer. Before connecting the tester, it is important to ensure that the transformer is de - energized and properly grounded to avoid electrical hazards. The test leads should be securely connected to the terminals to ensure accurate measurements.
  2. Measurement Process
    Once the test setup is complete, the turn - ratio tester applies a known voltage to the primary winding and measures the resulting voltage across the secondary winding. The tester then calculates the turn - ratio based on the measured voltages. In some cases, multiple measurements may be taken at different tap positions if the transformer is equipped with a tap - changer. This helps in verifying the turn - ratio at all possible operating conditions.
  3. Interpretation of Results
    The measured turn - ratio is compared with the design value. The acceptable tolerance for the turn - ratio is usually specified by the transformer manufacturer. If the measured turn - ratio falls within the tolerance range, the transformer is considered to be in compliance. However, if the measured value deviates significantly from the design value, further investigation is required to identify the cause of the deviation.

Impact of Turn - Ratio on Transformer Performance

  1. Voltage Regulation
    The turn - ratio has a direct impact on the voltage regulation of a transformer. Voltage regulation is defined as the change in the secondary voltage from no - load to full - load conditions. A proper turn - ratio ensures that the voltage regulation is within acceptable limits, which is crucial for maintaining a stable voltage supply to the load.
  2. Efficiency
    An incorrect turn - ratio can also affect the efficiency of the transformer. If the turn - ratio is not optimized, the transformer may draw more current than necessary, resulting in increased losses (both copper and iron losses). This not only reduces the overall efficiency of the transformer but also leads to higher operating costs.

Our Product Offerings in the Context of Turn - Ratio

As a dry - type transformer supplier, we offer a wide range of high - quality dry - type transformers, including the 160kVA Epoxy Resin Insulated Transformer, 500kVA Dry Type Transformer, and Amorphous Alloy Dry Type Distribution Transformer. All our transformers undergo rigorous turn - ratio testing during the manufacturing process to ensure they meet the highest quality standards. We also provide after - sales support, including turn - ratio testing and maintenance services, to help our customers keep their transformers in optimal condition.

Conclusion

The turn - ratio test is an indispensable part of the quality control and maintenance process for dry - type transformers. It helps in ensuring that the transformer operates as designed, detects potential faults, and assesses its long - term health. As a dry - type transformer supplier, we are committed to providing our customers with reliable products that have accurate turn - ratios. If you are in the market for dry - type transformers or need further information about turn - ratio testing and our products, please feel free to contact us for procurement and negotiation.

500kVA Dry Type Transformer160kVA Epoxy Resin Insulated Transformer

References

  • Grover, W. M. (1979). Transformer Engineering: Design and Practice. Wiley - Interscience.
  • McPherson, G., & Laramore, R. D. (1990). An Introduction to Electrical Machines and Transformers. Wiley.
  • Westinghouse Electric Corporation. (1982). Electrical Transmission and Distribution Reference Book.