Reliable Global Dry Type Distribution Transformers For Sale Online
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Product Introduction
SCB10 Dry-Type Power Transformer This series of transformers incorporates European dry-type transformer technology to ensure that the products meet strict fire prevention, waterproof and environmental protection standards.
This series optimizes the interlayer voltage and capacitance distribution by improving the high-voltage coil structure, enhancing the ability to resist atmospheric overvoltage and operating overvoltage, and improving the electric field distribution. This series of transformers is an ideal choice for power distribution systems and is often used in subways, shipbuilding, mining, chemicals, power companies, densely populated buildings and other environments with strict safety requirements.
Transformer Type |
Resin Cast Dry Type |
Model |
SCB10-50/10 |
Number of Phase |
Three Phase |
Winding Type |
Two Winding |
Winding Material |
Aluminum/Copper |
Rated Capacity |
50kVA |
High Voltage |
10/11kV |
Low Voltage |
0.4kV |
Tapping Range |
±2x2.5% |
Impedance Voltage |
4% |
Load Loss (120°C) |
1kW |
No-load Loss |
0.27kW |
No-load Current |
2% |
Frequency |
50/60Hz |
Connection Group |
Yyn0/Dyn11 |
Cooling Method |
ANAF |
Protection Level |
IP00/IP20/IP30 |
Temperature Rise |
100K |
Operation Altitude |
≤1000m |
Size |
950x750x915mm |
Weight |
575kg |
The protection measures for dry-type transformers mainly include the following:
Transformer door travel switch: This switch has 4, each set of normally closed contacts is connected in parallel. When the transformer door is closed, the normally closed contacts are disconnected and there is no electrical signal input for comprehensive protection. If any door is opened, the normally closed contacts are reset and there is an electrical signal input for comprehensive protection. It can be set to alarm or trip the high-voltage cabinet after the door is opened.
Transformer door electromagnetic lock: Used to prevent people from electric shock. When the transformer is powered on, the electromagnetic lock is energized. At this time, the door cannot be opened with the handle and needs to be opened with a special key.
Temperature protection: It is realized through temperature sensors, thermostats and cooling fans. The temperature sensor detects the winding temperature, the thermostat sets the high temperature alarm and over-temperature trip value, and the cooling fan starts cooling when the temperature reaches the set value.
Hot Tags: reliable global dry type distribution transformers for sale online, China reliable global dry type distribution transformers for sale online manufacturers, suppliers, factory, Three Phase Distribution Transformer, 11 kVA 415V Pole Mounted Current Transformer, Distribution Transformer, Amorphous Alloy Steel Transformer, compact unit substation, Cast Dry Transformer
You Might Also Like
Send Inquiry