10KV Fully Sealed Three-phase Oil-immersed Power Distribution Transformer
Nov 07, 2025
Leave a message
10kv Oil immersed Transformer Type
For HENAN GNEE ELECTRIC CO., LTD., a 10kv transformer can be a three-phase oil immersed transformer, a column mounted three-phase oil immersed transformer, or a three-phase pad mounted transformer. These types of transformers have the same principle, but their structures are different, and different types of transformers have different applications. HENAN GNEE ELECTRIC CO., LTD. provides you with the most ideal solution.
10kV three-phase oil immersed transformer (rated voltage 6kV-35kV)
Install a three-phase oil immersed transformer (rated voltage 2.4kv-34.5kv) on an 10kV column
10kV three-phase pad mounted transformer (rated voltage 2.4kv-34.5kv)
10kv Oil immersed Transformer Technical Specifications
- Input voltage: 10kV
- Output voltage: 0.4kV 0.415 kv 0.420kv 0.430kv 0.440kv
- Capacity: 30-2500 kva
- Frequency: 50/60 HZ
- Remark: voltage, capacity, frequency, connection group and loss can be customized according to customer requirements
|
S11 Capacity |
Rated voltage&Off-load tapping | Vector GroupSymbol |
NO-load loss(W) |
Load loss(W) | NO-load current(%) | Short circuit impedance(%) |
||||
| H.V(kv) | High pressure Tap range(%) |
L.V(kv) | ||||||||
| 30 kva | 11 10.5 10 6.3 6 |
±5% ±2x2.5% |
0.4 0.415 0.420 0.430 0.440 |
Dyn11 Yyn0 |
100 | 630/600 | 1.5 | 4 | ||
| 50 kva | 130 | 910/870 | 1.3 | 4 | ||||||
| 63 kva | 150 | 1090/1040 | 1.2 | 4 | ||||||
| 80 kva | 180 | 1310/1250 | 1.2 | 4 | ||||||
| 100 kva | 200 | 1580/1500 | 1.1 | 4 | ||||||
| 125 kva | 240 | 1890/1800 | 1.1 | 4 | ||||||
| 160 kva | 280 | 2310/2200 | 1 | 4 | ||||||
| 200 kva | 340 | 2730/2600 | 1 | 4 | ||||||
| 250 kva | 400 | 3200/3050 | 0.9 | 4 | ||||||
| 300 kva | 480 | 3830/3650 | 0.9 | 4 | ||||||
| 400 kva | 570 | 4520/4300 | 0.8 | 4 | ||||||
| 500 kva | 680 | 5410/5150 | 0.8 | 4 | ||||||
| 630 kva | 810 | 6200 | 0.6 | 4.5 | ||||||
| 800 kva | 980 | 7500 | 0.6 | 4.5 | ||||||
| 1000 kva | 1150 | 10300 | 0.6 | 4.5 | ||||||
| 1250 kva | 1360 | 12000 | 0.5 | 4.5 | ||||||
| 1600 kva | 1640 | 14500 | 0.5 | 4.5 | ||||||
| 2000 kva | 1940 | 18300 | 0.4 | 5 | ||||||
| 2500 kva | 2290 | 21200 | 0.4 | 5 | ||||||
Against the backdrop of global electricity demand growth, 10kV three-phase oil immersed transformers are widely used in rural power grids, industry, commerce, new energy, public facilities, and other fields. High reliability operational verification in over 50 countries and regions worldwide; Already sold to countries and regions such as East Asia, Central Asia, Southeast Asia, South Asia, etc
10kv Oil immersed Transformer Standar & Certifaication
1. Standards: GB, IEC, GOST, EN, NF, ANSI/IEEE (customizable according to customer standards)
2. Certification: ISO,CE,IEC,SABS,COC,CSA,UL
3. Efficiency: The efficiency of an 10kV three-phase oil immersed transformer can exceed 99%, which can meet the European 2015/2014/548/EC ecodesign Tier 2 energy efficiency regulations.
4. Maintenance free: IP65 protection level, dustproof and moisture-proof, maintenance free, designed for a lifespan of over 25 years.
5. Environmental protection and sustainable development: FR3 vegetable oil can be selected.
6. Overload capacity: Copper coil 10kv transformer allows short-term overload to 150% of rated capacity for no more than 2 hours, but requires monitoring of oil temperature (≤ 95 ℃).
Ethiopia 112KVA 10kv Oil immersed Transformer Case
This 112 KVA distribution transformer was delivered to Ethiopia in 2013, the rated power of the transformer is 112 KVA. This 112 KVA Step Down transformer 11kv to 0.4kv, the primary voltage is 11kv, the secondary voltage is 0.4kv. We adopted copper wire at HV side and copper foil at LV side.
112 KVA transformer specifications and data sheet
|
Delivered to |
Ethiopia |
|
Year |
2022 |
|
Model |
S11-112 KVA-11/0.4KV |
|
Type |
Oil Immersed Distribution Transformer |
|
Standard |
IEC60076 |
|
Rated Power |
112 KVA |
|
Frequency |
50 HZ |
|
Phase |
Three |
|
Cooling Type |
ONAN |
|
Primary Voltage |
11 KV |
|
Secondary Voltage |
0.4 KV |
|
Winding Material |
Copper |
|
Vector Group |
Dyn11 |
|
Impedance |
4% |
|
Tap Changer |
NLTC |
|
Tapping Range |
±2*2.5% |
|
No Load Loss |
0.24KW |
|
On Load Loss |
1.8KW |
|
Accessories |
Standard Configuration |
|
Remarks |
N/A |