view more21
Mar
Characteristics Of Oil-immersed TransformersAdvantage: 1. Transformer oil has good insulation performance and good thermal conductivity. At the same time, transformer oil is cheap. 2. It can ...
view more20
Mar
Key Points For Selecting Oil-immersed TransformersLoad properties: 1) When there are a large number of primary or secondary loads, it is recommended to install two or more transformers. When any on...
view more19
Mar
Performance Characteristics Of Oil-immersed Transformersa. Except for small-capacity copper wires, the low-voltage windings of oil-immersed transformers generally adopt a cylindrical structure with coppe...
view more18
Mar
Development History Of Oil-immersed TransformersTransformer oil is a petroleum-based liquid that has the potential to burn and has disadvantages in terms of environmental protection. However, due...
view more17
Mar
What Is The Operating Temperature Of Dry-type Transformers?1. Most dry-type transformers now use H-class insulation materials, so generally the temperature of dry-type transformers should be below 180°C...
view more16
Mar
Safety Precautions For Dry-type Transformers1. Shake measurement of insulation resistance must be carried out by two people. 2. It is strictly forbidden to touch the transformer before chargi...
view more15
Mar
Maintenance Methods Of Dry-type Transformers1. Put in the spare transformer, disconnect the circuit breaker on the low-voltage side of the transformer for maintenance, remove the operating fu...
view more14
Mar
What Are The Advantages Of Dry-type Transformers?Dry-type transformers are mainly composed of iron cores made of silicon steel sheets and coils cast by epoxy resin. Insulating cylinders are placed...
view more13
Mar
Difference Between Oil Type And Dry Type TransformersOil-type transformers and dry-type transformers are two common types of transformers. Their main differences are as follows: 1. Insulating medium: ...
view more12
Mar
Dry-type Transformer Temperature RegulationsThe temperature range of dry-type transformer is: below 180℃. Generally speaking, the allowable temperature of a dry-type transformer is related to...
view more11
Mar
Dry-type Transformers Should Meet The Requirementsa) When the transformer and the low-voltage distribution cabinet are installed in parallel, the protection grade of the shell is not lower than IP3...
view more10
Mar
How To Check Dry-type Transformer?1. Is there any abnormal sound or vibration? 2. Whether there is any discoloration caused by local overheating, harmful gas corrosion, etc. that ma...