3 Phase Pad Mounted Transformer

3 Phase Pad Mounted Transformer

GNEE's dead-front transformers can be customized according to your needs and technical parameters. The highest voltage level can reach 44kV, and the capacity can reach 10MVA. Primary Voltage Ratings: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2,44 kV or others
Secondary Voltage Ratings: 240/480/480Y-277/600Y-347 or others
H.V. TAP RANGE: ±2×2.5% or others
CONNECTION TYPE: Dyn11/Yyn0 or others
TYPE: Loop feed/Radial feed
BIL: 30-200 kV
Power Rating: 75 kVA—10000 kVA
Send Inquiry
Chat Now

Have questions? GNEE sales representatives are available for live chat now

Send E-mail: sales@gneeelectric.com

Tel: +8615824687445

Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 3 phase pad mounted transformer in China. If you're going to buy customized 3 phase pad mounted transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.

 

GNEE Transformer is a professional pad mounted transformer manufacturer located in Henan, China.Specializes in manufacturing 3 phase pad mounted transformers with voltages up to 46 kV and power ratings up to 10 MVA. With over 200 projects completed annually in the Americas, we've installed over 10,000 transformers in the European and American markets.

 

Application: BESS, EV Charging, Ultiliy, Bitcoin Mining, Data Center,Real Estate, Solar photovoltaic power generation

 

The specifications of 3 phase pad mounted transformer vary according to different standards, as shown in the table below for IEEE and CSA standards.

In addition to the standard specifications mentioned above, GNEE Transformer can also accommodate customized specifications according to your requirements, such as 1250kVA, 2550kVA, 2600kVA, 3500kVA, 4000kVA, 4500kVA, 7MVA, 8MVA, etc.

 

The three phase pad mounted transformer is an oil filled distribution transformer designed for underground distribution loads in commercial settings like shopping centers, schools, and industrial plants.

 

Contact us now to receive a quote for your specific three phase pad mounted transformer specifications.

CSA Std Kiovolt-ampere ratings IEEE Std Kiovolt-ampere ratings
75 kVA &150 kVA 1280mm/1480mm(With) 45 kVA 1000 kVA
225 kVA,300 kVA, 500 kVA 1480mm(With) 75 kVA 1500 kVA
750 kVA 1730mm(With) 112.5 kVA 2000 kVA
1000 kVA 1730mm(With) 150 kVA 2500 kVA
1500 kVA 1730mm(With) 225 kVA 3750 kVA
2000 kVA 1730mm(With) 300 kVA 5000 kVA
2500 kVA 1730mm(With) 500 kVA 7500 kVA
3000 kVA 1730mm(With) 750 kVA 10000 kVA

product-1045-622

Contact GNEE Transformer for special requirements

Email: sales@gneeelectric.com

 

Three Phase Dead front loop feed pad mount transformner

Pad Mounted Transformer Price

The table below provides a price list for 3 phase pad mounted transformers for your reference only. Please note that prices may vary significantly based on different configurations and requirements. Contact us now to get an accurate price for your specific pad mounted transformer.

Pad Mounted Transformer Price List
45 kVA 6-8K 1000kVA 18-36K
75 kVA 8-10K 1500 kVA 20-40K
112.5 kVA 9-12K 2000 kVA 22-45K
150 kVA 10-15K 2500 kVA 25-50K
225 kVA 12-18K 3000kVA 28-56K
300 kVA 13-20K 3750 kVA 30-60K
500 kVA 14-25K 5000 kVA 40-70K
750 kVA 15-30K 10 000 kVA 100-150K

 

Pad Mounted Transformer Parts
Standard Parts Optional Parts
ELSP fuse
Bay-O net fuse
Oil level gauge
Drip tray
Drain valve
HV bushings
LV bushings
Carbon steel tank
Liquid temperature gauge
Pressure vacuum gauge
Oil drain valve with sampler
Tap changer(5-position/7-positon)
Load break switch(4-position or 2-position)
CT
IR window
ISO link
Elbow arresters
Kirk key interlock
Pressure relief device
Sudden pressure relay
IFD(fault indicator light)
Loadbreak feed-thru insert
DV( dual voltage switch)
304/306 stainless steel tank
Gauges with alarm/trip contacts
NEMA 4 or NEMA 4X rated enclosure
Under oil arrester with disconnector
Pad Mounted Transformer Parts

 

Three Phase Dead front loop feed pad mount transformner Dead Front Transformer

 

A dead front transformer is a pad-mounted transformer that features fully enclosed electrical connections and components, ensuring that there are no exposed live parts or terminals on the front panel. This design enhances safety by preventing accidental contact with energized elements. Dead front transformers are commonly used in outdoor applications for secure electrical power distribution.

 

The dead-front pad-mounted transformer is equipped with three/six high-voltage bushings on the high-voltage side, which are completely enclosed in insulating material for enhanced safety. When the hatch is opened, the high-voltage terminal remains unexposed, ensuring higher safety performance.

 

Dead-front transformers have two configurations: loop feed and radial feed. In the radial feed configuration, there are three bushings on the high-pressure side, while in the loop feed configuration, there are six bushings on the high-pressure side. In the loop feed setup, three bushings can be connected to cables, and the remaining three bushings can be connected to arresters. Alternatively, all six bushings can be connected to cables.

 

Dead front transformer comes with 200A and 600A separate bushings (bushing well + bushing insert) or a one-piece bushing. In the case of the dead-front transformer with a 200A HV bushing, it can be fully shielded and insulated for the load-break elbow connector connection to the underground cable. For the dead-front transformer with a 600A HV bushing, the current needs to be converted into 200A through the T-body dead-break connector before being connected to the underground cable via the load-break elbow connector. ome BESS projects require 3-phase pad-mounted transformers with 900A dead front bushings, and GNEE Transformer can meet these requirements. We have completed numerous BESS and photovoltaic projects.

2600 kVA Pad Mounted Transformer for Cryptocurrency Mining

 

gNEE Transformer pad mounted transformer projects

2600 kVA Pad Mounted Transformer for Cryptocurrency Mining

2 MVA Pad Mounted Transformer for Utility

1000 kVA Pad Mounted Transformers For Jamaica Market

2000 kVA Pad Mounted Transformers for Canadian Utility

1750 kVA Pad Mounted Transformer for the Dominica

2600 kVA Pad Mounted Transformer For Crypto Mine In Kansas

2550 kVA Pad Mounted Transformer For Data Center in Mexico, Missouri

Daelim Transformer Custom 1500 kVA Pad Mounted Transformer for Canada

Pad Mounted Transformer for BESS System 4.0 MVA in Riverside County, California

3 Phase Pad Mounted Transformer Sizes

The sizes of 3 phase pad mounted transformers vary based on power ratings, primary and secondary voltages, materials, etc. The table below provides specific dimensions of some pad mounted transformer projects completed by Daelim Transformer for your reference only.

3 Phase Pad Mounted Transformer Sizes
kVA Type HV LV W(mm) D(mm) H(mm)
75 radial 25000Delta 480GrdY/277 1280 1085 1085
150 loop 14400v 600GrdY/347 1480 1250 1750
225 radial 4160Delta 347GrdY/600V 1480 1295 1750
300 loop 345000 208GrdY/120 1500 1730 1850
500 loop 1247Grdy/7200V 600Y/347 1447 1800 1750
750 radial 24940GrdY/14400 800GrdY/462 1485 1730 1750
1,000 radial 249400DELTA 480V 1730 1350 1850
1,250 loop 25000V 416V 1730 1320 1920
1,500 loop 4160GRDY/2400 600GrdY/347 1730 1910 1965
1,500 loop 34500DELTA 480GrdY/277 2220 2069 2065
1,750 loop 13800Delta 480GrdY/277 1730 2304 1900
2,000 radial 4160DELTA 415GrdY/240 1730 1950 1810
2,500 loop 25000DELTA 600GrdY/347 1730 2560 1960
2,550 loop 12470DELTA 415GrdY/240 1730 2000 2200
2600 Loop 34500DELTA 416GrdY/240 1730 1695 2290
3000 Loop 27,600DELTA 13,800DELTA 1830 2360 2000
4000 loop 27600Delta 600GrdY/347 1900 2500 2010
5000 radial 13,800DELTA 4,160GrdY/2,400 1900 2735 2500
7000 loop 27,600DELTA 13,800DELTA 2200 3030 2080
7500 loop 249400DELTA 4.16kv Wye 2300 3200 2100
10000 loop 24900GrdY/14400 600V 2800 3500 2560

 

If you need to know the specific size of the transformer you require, please send the transformer specifications to sales@gneeelectric.com.

product-916-403

product-912-441

product-909-509

product-1123-477

product-1119-472

3 Phase pad mounted transformer grounding

3 Phase Pad Mounted Transformer Grounding

CSA Standard Grounding Provisions

According to CSA standards, grounding provisions for three phase pad mounted transformers include two vertically mounted earth spade terminals welded to the tank wall at a height of at least 150 mm at or above sill level. One terminal is placed on the high-voltage side and one on the low-voltage side. For GrdY transformers, the high-voltage side terminals shall be designated and marked H0. Both terminals shall be unpainted, made of stainless steel, with a width of not less than 40 mm and a thickness of not less than 6 mm. Each terminal is provided with two 14 mm (9/16 inches) holes, spaced 44.5 mm apart.

 

IEEE Standard Grounding Provisions

For transformers of 500 kVA and below, two steel pads shall be provided, each having a 1/2% inch 13 UNC tapped hole and a minimum thread depth of 11 mm (0.44 in.).

For transformers above 500 kVA, two unpainted copper-faced steel or stainless steel pads measuring 51 x 89 mm (2.0 x 3.5 in) each shall be provided. Each pad has two holes spaced 44 mm (1.75 in) on centers and tapped for a 1/2%-inch 13 UNC thread. The copper finish shall be not less than 0.5 mm (0.02 in.) thick, and the thread depth of the hole shall be not less than 13 mm (0.5 in).

 

Location

The ground pads should be welded on or near the transformer base, one in each high-voltage compartment and one in each low-voltage compartment. If the transformer tank and compartment are separate, these pads shall be electrically connected.

 

Optional features  
High and low voltage bushings Overcurrent protection
200 A (15, 25 kV bushing inserts Bay-O-Net fusing (Current sensing, dual sensing, dual element,high amperage overload)
200 A (15, 25 kV) feed thru inserts Bay-O-Net expulsion fuse in series with a partial range under-oil ELSP current limiting fuse (below 23 kV)
200 A (15, 25 kV)(HTN) bushing wells with removable studs Cartridge fusing in series with a partial range underoil ELSP current limiting fuse (above 23 kV)
High-voltage 600 A (15,25, 35 kV) deadbreak one-piece bushings MagneXTM interrupter with ELSP current-limiting fuseVacuum Fault Interrupter (VFl)
Low voltage 6-, 8-holes spade Visible break window
Low voltage 12-,16-,20-holes spade (750-2500 kVA) Fuse/switch interlock
Low voltage bushing supports Valves/plugs
Tank/cabinet features Drain/sampling valve in high-voltage compartment
Stainless steel tank base and cabinet Globe type upper fill valve
Stainless steel tank base, cabinet sides and sill Overvoltage protection
100% stainless steel unit Distribution,, intermediate-, or station-class surge arresters
Service entrance (2 inch) in sill or cabinet side Elbow arresters (for dead-front connections)
Touch-up paint (domestic) Metering/fan/control
Copper ground bus bar Full metering package
Kirk-Key provisions Current Transformers (CTs)
Nitrogen blanket Metering Socket
Bus duct cutout NEMA 4 control box (optional stainless steel)
Special designs NEMA 7 control box (explosion proof)
Factory Mutual (FM) Fan Packages
UL Classified Testing
Triplex Customer test witness
High altitude Customer final inspection
K-Factors Zero Sequence lmpedance Test
Step-up Heat Run Test
Critical application ANSl lmpulse Test
Modulation transformers Audible Sound Level Test
Seismic applications (including OSHPD) RIV (Corona) Test
Switches Dissolved Gas Analysis (DGA) Test
One, two, or three On/Off loadbreak switches 8- or 24-Hour Leak Test
4-position loadbreak V-blade switch or Tblade switch Coatings (paint)
Delta-wye switch ANSI Bell Green
3-position VBlade selector switch ANSI #61 Light Gray
100 A, 150 A, 300 A tap changers ANSI #70 Sky Gray
Dual voltage switch Special paint available per request
Visible break with VFl interrupter interlock Nameplate
External visible break (15, 25, and 35 kV, up to 3 MVA) Stainless steel nameplate
External visible break with gauges (15, 25, and 35 kV, up to 3MVA) Decals and labels
Gauges and devices High voltage warning signs
Liquid level gauge (optional contacts) Mr. Ouch
Pressure vacuum gauge (optional contacts and bleeder) Bi-lingual warning
Dial-type thermometer (optional alarm contacts) DOE compliant
Cover mounted pressure relief device (optional alarm contacts) Customer stock code
Ground connectors Customer stenciling
Hexhead captive bolt Shock and arc flash warning decal
Molded case circuit breaker mounting provisions Non-PCB decal
External gauges in padlockable box  

 

gnee pad mounted transformer factory

Pad Mounted Transformer Factory

Packaging&shipping

Residential pad mounted transformer

 

Hot Tags: 3 phase pad mounted transformer, China 3 phase pad mounted transformer manufacturers, suppliers, factory, pressure relief device of pad mounted transformer, Dry Type Three Phase Pad Mounted Transformer, tank of pad mounted transformer, pad mounted transformer storage, single-phase pad mounted transformer, pad mounted transformer buchholz relay

Send Inquiry