12 MVA Three Phase Power Transformer
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
The 12 MVA three-phase power transformer features a sealed tank structure and operates at a high voltage of 38 kV and a low voltage of 13.2 kV. It is meticulously designed and constructed in accordance with the ANSI C57 standard. Employing a two-stage air cooling system, this transformer ensures efficient heat dissipation.With a temperature rise specification of 55℃/65℃, the transformer is capable of achieving a rated capacity of 12 MVA at a 55℃ temperature rise, extendable up to 20 MVA. Similarly, at a 65℃ temperature rise, it boasts a rated capacity of 13.5 MVA, with the maximum capacity reaching 22.5 MVA.
Three Phase Power Transformer Specifications
| Rating | 12MVA 16MVA 20MVA |
| Primary Voltage | 38000V Delta |
| Secondary Voltage | 13200GrdY/7620V |
| Frequency | 60Hz |
| Vector Group | Dyn1 |
| Winding Material | Copper |
| Load Loss | 53900W |
| No Load Loss | 10600W |
| Impedance | 6.50% |
| Altitude | ≤1000m |
| Color | ANSI 61 Light Grey |
| Weight | 6400 lb |
| D*W*H(mm) | 4700*4650*3800 |
12MVA Power Transformer Picturers

Testing Procedure
- By IEEE Std C57.12.00 standards, the following tests are conducted:
- Appearance check
- Transformer oil test
- Measurement of dissolved gases in transformer oil
- Measurement of voltage ratio and verification of phase displacement
- Measurement of winding resistance
- Measurement of DC insulation resistance between each winding to earth and between windings
- Check of core and frame insulation for liquid-immersed transformers with core or frame insulation
- Measurement of determination and dissipation factor of the insulation system capacitances
- Measurement of no-load loss and current
- No-load current harmonics measurement
- Measurement of short-circuit impedance and load loss
- Lightning impulse test
- Applied voltage test
- Induced voltage withstand test
- Induced voltage test with partial discharge (PD) measurement
- Determination of sound levels
- Temperature rise test
- Measurement of frequency response
- Auxiliary wiring insulation test
- Verification of the ratio and polarity of built-in current transformers
- Leak testing with pressure for liquid-immersed transformers
- Inspection and function test of the control circuit
Packaging&Shipping

Hot Tags: 12 mva three phase power transformer, China 12 mva three phase power transformer manufacturers, suppliers, factory, step up power transformer, 150kVA Oil Immersed Distribution Transformer, Amorphous Alloy Steel Transformers, Dry Type Pad Mounted Transformer, Amorphous Alloy Metal Transformer, Step Down Power Transformer