80KVA 3 Phase Oil-immersed Power Transformer
Capacity: 80KVA
Delivery Year: 2023
Country: Indonesia
Key Advantages:
Efficient Cooling: Equipped with an Oil immersed self cooled transformer design, ensuring stable operation in tropical high-temperature environments and minimizing downtime.
Adaptive Performance: The Oil Immersed Transformer features a three-phase balanced structure, ideal for fluctuating industrial loads in factories.
Safety and Reliability: The oil filled transformer uses an insulating oil system to isolate circuits from air, reducing oxidation and spark risks while extending equipment lifespan.
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 80kva 3 phase oil-immersed power transformer in China. If you're going to buy customized 80kva 3 phase oil-immersed power transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
Product Functional Introduction of 3 Phase Oil-immersed Power Transformer
This Oil Immersed Transformer is designed for industrial and commercial applications, offering high reliability and efficiency. Key features include:
Cooling & Heat Dissipation: The Oil immersed self cooled transformer technology utilizes natural oil circulation to maintain stable performance in high-temperature or high-load conditions, reducing temperature-related performance loss.
Three-Phase Balance: Precisely engineered for three-phase power systems, it minimizes harmonic interference and ensures uniform voltage output.
Enhanced Safety: The oil filled transformer ensures dual protection through insulating oil, providing superior insulation to prevent short circuits and arc discharge, meeting international safety standards.
Additionally, the transformer supports customized input/output voltage configurations, making it suitable for mining, manufacturing plants, data centers, and other high-load power conversion scenarios.

Products parameter
| Rated capacity(kVA) |
High voltage(kV) | Tap range | Low voltage(kV) | connected group label | No-load loss(w) |
Load loss (75ºC)(W) |
No-load current(%) | Impedance voltage(%) |
| 30 | 6 6.3 6.6 10 10.5 11 |
±2*2.5 ±5 |
0.4 | Dyn11 Yyn0 Yzn11 |
33 | 535/510 | 1.5 | 4 |
| 50 | 43 | 780/745 | 1.2 | |||||
| 63 | 50 | 930/890 | 1.1 | |||||
| 80 | 60 | 1120/1070 | 1.0 | |||||
| 100 | 75 | 1350/1285 | 0.9 | |||||
| 125 | 85 | 1615/1540 | 0.8 | |||||
| 160 | 100 | 1975/1880 | 0.6 | |||||
| 200 | 120 | 2330/2225 | 0.6 | |||||
| 250 | 140 | 2275/2120 | 0.6 | |||||
| 315 | 170 | 3275/3120 | 0.5 | |||||
| 400 | 200 | 3865/3675 | 0.5 | |||||
| 500 | 240 | 4625/4400 | 0.5 | |||||
| 630 | Dyn11 Yyn0 |
320 | 5300 | 0.3 | 4.5 | |||
| 800 | 280 | 6415 | 0.3 | |||||
| 1000 | 450 | 8800 | 0.3 | |||||
| 1250 | 530 | 10260 | 0.2 | |||||
| 1600 | 630 | 12400 | 0.2 | |||||
| 2000 | 710 | 14800 | 0.2 | 5 | ||||
| 2500 | 860 | 16300 | 0.2 |
Maintenance Guidelines
The maintenance of an Oil Immersed Transformer should focus on the following key areas:
Daily Checks (Keyword Distribution)
Cooling System Inspection: Regularly monitor the oil level and piping of the Oil immersed self cooled transformer for leaks, ensuring oil cleanliness. If the oil level is insufficient, add the same type of insulating oil and check the seals.
Oil Condition Monitoring: The insulating oil in the oil filled transformer should be tested annually for its dielectric strength and water content. Replace it promptly if performance deteriorates.
Periodic Maintenance (Keyword Distribution)
Enclosure and Sealing: Inspect the transformer enclosure for deformation or corrosion, ensuring all sealing components (such as valves and flanges) are leak-free to prevent moisture ingress that could affect the insulation performance of the Oil Immersed Transformer.
Load and Temperature Monitoring: When operating under high load for extended periods, use an infrared thermometer to monitor coil temperatures. Investigate overload or poor cooling issues if the temperature exceeds the design range.
Fault Response (Keyword Distribution)
Abnormal Sounds or Odors: If you hear cracking sounds or smell a burnt odor, immediately cut off the power and inspect the oil filled transformer for localized discharge or insulation aging.
Oil Color Changes: If the oil appears cloudy or turns dark brown, this indicates possible overheating or oxidation. Shut down the system immediately for inspection and handling.
Precautions:
During maintenance, ensure the transformer is powered off, wear appropriate protective gear, and follow the safety guidelines provided by the manufacturer of the Oil Immersed Transformer. Avoid direct contact with insulating oil or live components.

video
about us
GNEE Group:
Global Transformer Supply Chain Integration Expert (2008 - Present)
Founded in 2008, GNEE Group has undergone fifteen years of deep industry cultivation, successfully transforming from a regional trader to a global supply chain management expert. As a pioneer in the integration of the steel industry chain, the group has established a full-cycle value system that spans raw material procurement, production coordination, logistics optimization, and terminal services, setting an innovative operational benchmark in the global transformer distribution sector. In the era of Industry 4.0, GNEE Group is accelerating towards its goal of becoming a global integrator oftransformer industry value through digital restructuring and green supply chain construction.


Our factory

Packing and Delivery

FAQ
Q1: How to Choose Between Oil-Immersed, Dry-Type, or Amorphous Alloy Transformers Based on Needs?
A:Oil-immersed transformers (e.g., 30-2500 kVA/10 kV Oil-Immersed Three-Phase Dual-Winding):
Applicable scenarios: Large factories, substations, outdoor high-voltage power distribution.
Advantages: Excellent heat dissipation for high loads and high-temperature environments, but requires fire prevention and oil leakage precautions.
Dry-type transformers (e.g., Epoxy resin-cast type, Dry-Type Dual-Winding):
Applicable scenarios: Indoor installations (e.g., data centers, commercial buildings), environments with strict fire safety requirements.
Advantages: No insulation oil, pollution-free, low noise, but requires ventilation for heat dissipation.
Amorphous alloy transformers (e.g., Amorphous Alloy Dry-Type):
Applicable scenarios: Grid-end applications, rural power supply, energy-efficient systems.
Advantages: Reduces no-load loss by over 70%, higher efficiency than traditional transformers, ideal for long-term low-load operations.
Q2: Which Equipment is Suitable for Rectifier Transformers (30-3200 kVA Rectifier Type)?
A: Designed specifically for rectifier equipment, such as:
Electroplating lines, electrolytic cells.
Aluminum/copper electrolysis production.
DC motor drive systems.
Features: Three-phase input, adjustable DC voltage output. Note: Harmonic loads may impact transformer performance.
Q3: What are the Differences Between Prefabricated Substations (European Style) and Combined Transformers (Combined Type)?
A:Prefabricated Substations:
High integration: Includes transformers, low-voltage cabinets, and protection devices pre-installed in weatherproof/fire-resistant enclosures.
Applicable scenarios: Rapidly deployable outdoor power systems (e.g., temporary construction sites, remote areas).
Combined Transformers:
Functional integration: Typically combines transformers, metering devices, and protection equipment to simplify power distribution.
Applicable scenarios: Power distribution hubs for small/medium factories or commercial complexes.
Q4: What is the Voltage Adjustment Method for 30-2500 kVA Dual-Winding Non-Adjustable Voltage Transformers?
A:Non-adjustable type: Fixed output voltage set at factory (e.g., 10 kV input → 400 V output); no on-site adjustment.
Applicable scenarios: Stable voltage environments with minimal load fluctuations (e.g., fixed production lines).
For voltage adjustment, choose on-load tap-changing transformers (customizable).