Low Voltage Power Cable
Copper & Aluminum Conductor Options
Armored & Unarmored Constructions Available
Flame Retardant & UV Resistant Outdoor Designs
Custom Sizes for 3 Core, 4 Core & Multi-Core Configurations
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of low voltage power cable in China. If you're going to buy customized low voltage power cable made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
What Is Low Voltage Power Cable?
A low voltage power cable is an electrical cable designed to transmit electric power at voltages typically rated up to 0.6/1kV (1000V) AC, with some variants extending to 1.8/3kV for specialized applications. As one of the most fundamental components in modern electrical distribution systems, lv power cable serves as the critical link between power sources and end-use equipment across residential, commercial, industrial, and infrastructure projects.
Our comprehensive range of low voltage power cables includes XLPE insulation Unarmoured power cable, XLPE insulation armoured power cable, PVC insulated Unarmoured power cable, and PVC insulated armored power cable options. We also supply specialty products such as NYY-J NYY-O Cable and XHHW THHN Cable to meet diverse international standards and project requirements.

Whether you need an outdoor low voltage cable with UV-resistant sheathing, a robust low voltage armored cable for direct burial installations, or precision low voltage control wire for automation systems, our product portfolio delivers reliable performance backed by rigorous quality testing.
💡 Not Sure Which LV Cable You Need?
Our engineering team can help you select the perfect low voltage power cable for your specific application. Tell us your project requirements and get a customized recommendation within 24 hours.
Types of Low Voltage Power Cables
As professional low voltage cable suppliers, we offer a comprehensive range of LV cable solutions designed for diverse installation environments and performance requirements. Explore our product categories below:
XLPE Insulated Power Cables
Cross-linked polyethylene insulated cables offer excellent thermal stability with a maximum conductor temperature of 90°C. Ideal for high-load applications and demanding environments.
- Unarmoured: XLPE insulation Unarmoured power cable for indoor, conduit, and cable tray installations
- Armoured: XLPE insulation armoured power cable for direct burial and outdoor industrial projects
- Voltage: 0.6/1kV up to 1.8/3kV
- Standards: IEC 60502-1, BS 5467, GB/T 12706
PVC Insulated Power Cables
Polyvinyl chloride insulated cables provide reliable electrical performance with excellent flexibility and cost-effectiveness. Suitable for general-purpose power distribution.
- Unarmoured: PVC insulated Unarmoured power cable for fixed indoor installations
- Armoured: PVC insulated armored power cable for underground and outdoor use
- Voltage: 0.6/1kV
- Standards: IEC 60502-1, BS 6004, AS/NZS 5000.1
NYY-J / NYY-O Cable
European-standard power cables with copper conductors, PVC insulation, and PVC outer sheath. NYY-J includes a green-yellow protective ground wire; NYY-O does not.
- Copper conductor, PVC insulation, PVC sheath
- Unarmoured design for indoor and protected installations
- Widely used in European markets and beyond
- Standards: VDE 0276-603, DIN EN 50525
XHHW / THHN Cable
North American standard building wires with cross-linked polyethylene (XHHW) or thermoplastic high-heat-resistant nylon (THHN) insulation. Perfect for commercial and industrial wiring.
- XHHW: XLPE insulation, wet/dry locations rated
- THHN: PVC/Nylon insulation, dry locations rated
- Stranded or solid copper conductors
- Standards: UL 44, UL 83, NEC compliant
3 Core Low Voltage Cable
Three-core LV cables for three-phase power distribution systems. Available with copper or aluminum conductors, in both armored and unarmored constructions.
- Conductor sizes: 1.5mm² up to 630mm²
- Armored options: STA (Steel Tape Armour), SWA (Steel Wire Armour)
- Ideal for motor circuits, three-phase equipment, and sub-main distribution
- Custom color coding available per project requirements
4 Core Low Voltage Cable
Four-core LV cables featuring three phase conductors plus one neutral conductor. Essential for balanced three-phase systems with neutral return.
- Configurations: 3+1 (equal phase + reduced neutral) or 4 equal cores
- Conductor sizes: 1.5mm² up to 630mm²
- Armored and unarmored versions available
- Perfect for commercial buildings, data centers, and industrial plants
Outdoor Low Voltage Cable
Specialized outdoor-rated LV cables designed to withstand harsh environmental conditions including UV exposure, moisture, temperature extremes, and mechanical stress.
- UV-resistant outer sheath (PE or special PVC compound)
- Water-blocking construction for direct burial
- Rodent and termite resistant options available
- Flame retardant and low smoke variants
Low Voltage Control Wire
Multi-core control cables for signal transmission, automation systems, and control circuits in industrial, commercial, and infrastructure applications.
- Core configurations: 2 to 61 cores or more
- Conductor sizes: 0.5mm² to 6mm²
- Shielded and unshielded options
- Screened variants for EMI-sensitive applications

🔍 Need a Custom Cable Configuration?
We specialize in custom low voltage cable sourcing and supply solutions. Whether you need unusual core configurations, special insulation materials, or unique armoring requirements, our engineering team works closely with partner factories to deliver cables tailored to your exact specifications. No MOQ for custom samples - request yours today.
Low Voltage Power Cable Specifications
Our low voltage power cable range is sourced from certified partner factories and manufactured to the highest international standards, ensuring consistent quality and reliable performance. Below are the key technical specifications for our standard product lines:
General Specifications of Low Voltage Power Cable
| Parameter | Specification | Options |
|---|---|---|
| Rated Voltage | 0.6/1kV (U0/U) | 1.8/3kV available upon request |
| Conductor Material | Copper (Class 2 stranded) | Aluminum, Class 1 solid, Class 5 flexible |
| Conductor Shape | Round compacted | Sectored, round uncompacted |
| Insulation Material | XLPE (Cross-linked PE) | PVC, EPR, LSZH |
| Max. Conductor Temp. | 90°C (XLPE) / 70°C (PVC) | 105°C high-temp variants |
| Armoring Type | STA (Steel Tape Armour) | SWA (Steel Wire), AWA, Unarmoured |
| Outer Sheath | PVC (ST2) | PE, LSZH, FRLS, HDPE |
| Number of Cores | 1, 2, 3, 3+1, 4, 4+1, 5 core | Custom multi-core configurations |
| Conductor Cross-Section | 1.5mm² – 630mm² | Larger sizes available on request |
XLPE Insulated LV Cable Data
| Conductor Size (mm²) | 3 Core Cable Diameter (approx.) | 3 Core Cable Weight (kg/km) | Current Rating (A, in air) | Voltage Drop (mV/A.m) |
|---|---|---|---|---|
| 16 | 22.5 mm | 780 kg/km | 86 A | 2.5 mV/A.m |
| 25 | 25.8 mm | 1,120 kg/km | 112 A | 1.7 mV/A.m |
| 35 | 28.4 mm | 1,450 kg/km | 138 A | 1.25 mV/A.m |
| 50 | 31.5 mm | 1,890 kg/km | 168 A | 0.93 mV/A.m |
| 70 | 35.8 mm | 2,560 kg/km | 213 A | 0.67 mV/A.m |
| 95 | 39.6 mm | 3,340 kg/km | 260 A | 0.50 mV/A.m |
| 120 | 43.2 mm | 4,080 kg/km | 300 A | 0.41 mV/A.m |
| 150 | 47.0 mm | 4,980 kg/km | 345 A | 0.34 mV/A.m |
| 185 | 51.5 mm | 6,020 kg/km | 390 A | 0.28 mV/A.m |
| 240 | 57.8 mm | 7,650 kg/km | 455 A | 0.23 mV/A.m |
| 300 | 63.5 mm | 9,350 kg/km | 525 A | 0.19 mV/A.m |
Note: Values are approximate and based on XLPE insulated, copper conductor, PVC sheathed unarmoured cables. Actual values may vary by manufacturer, installation conditions, and ambient temperature. Contact our engineering team for precise calculations for your project.
Low Voltage Power Cable Applications
As trusted low voltage cable suppliers to global markets, our lv power cable solutions serve a wide spectrum of industries and applications. From residential buildings to large-scale industrial complexes, our cables deliver consistent, safe, and efficient power distribution.
🏢Commercial Buildings:Office towers, shopping malls, hotels, hospitals, and educational institutions
🏭Industrial Plants:Manufacturing facilities, processing plants, warehouses, and production lines
🏠Residential Developments:Apartment complexes, housing estates, and residential infrastructure
⚡Power Distribution:Substations, transformer connections, and distribution networks
🌞Renewable Energy:Solar farms, wind power installations, and energy storage systems
🚇Infrastructure:Railways, airports, tunnels, and utility infrastructure projects
⛽Oil & Gas:Refineries, petrochemical plants, and offshore platforms
📡Data & Telecom:Data centers, telecom towers, and communication facilities

Common Installation Scenarios
- Indoor Installation: PVC insulated Unarmoured power cable and XLPE unarmoured cables for cable trays, conduits, and building wiring
- Direct Burial: low voltage armored cable with SWA or STA protection for underground installations without conduit
- Outdoor Overhead: outdoor low voltage cable with UV-resistant PE sheath for aerial and exposed outdoor applications
- Control Systems: low voltage control wire for PLC systems, motor control centers, and industrial automation
- Hazardous Areas: Special flame-retardant and low-smoke zero-halogen (LSZH) cables for tunnels, metro systems, and high-risk environments
Core Advantages of Our Low Voltage Power Cables
When you choose us as your low voltage cable suppliers, you're partnering with a trusted supplier committed to quality, reliability, and customer success. Here's what sets our low voltage power cable range apart:

01 Premium Raw Materials
99.99% pure oxygen-free copper conductors and virgin-grade insulation materials sourced from approved suppliers, ensuring consistent electrical performance and long service life.
02 Rigorous Quality Testing
Every cable undergoes 10+ quality checks including high-voltage testing, conductor resistance measurement, insulation thickness verification, and mechanical property testing before shipment, all conducted at our partner factories and verified by our own QC team.
03 Global Standards Compliance
All cables are manufactured to IEC, BS, ASTM, AS/NZS, DIN, and VDE standards by our certified partner factories. Our partner testing labs are ISO/IEC 17025 accredited, with third-party verification from KEMA, BASEC, and SGS available.
04 Custom Sourcing Solutions
Flexible supply capabilities allow us to source custom cable designs, sizes, and specifications from our partner factories. From special conductor stranding to unique sheath materials - we've got you covered.

Ready to Get Your Low Voltage Power Cable Quote?
Send us your specifications - receive a detailed quotation within 24 hours. Free samples available for quality verification.


FAQ
What is the difference between XLPE and PVC insulated cables?
XLPE (Cross-linked Polyethylene) insulated cables offer higher temperature resistance (90°C continuous vs. 70°C for PVC), better electrical properties, and longer service life. PVC insulated cables are more economical and flexible, making them suitable for general-purpose applications. XLPE insulation armoured power cable is typically used for higher-load industrial and outdoor installations, while PVC insulated armored power cable is common in commercial and residential projects.
How do I choose between armored and unarmored cables?
Armored cables (with steel wire or steel tape armor) provide mechanical protection for direct burial, outdoor installations, and areas prone to impact or rodent damage. Unarmored cables are lighter, more flexible, and more economical - ideal for indoor installations in cable trays, conduits, or ducts. If you need outdoor low voltage cable for direct burial, choose a low voltage armored cable. For protected indoor runs, unarmored is sufficient.
What is NYY-J vs NYY-O cable?
NYY-J NYY-O Cable are European-standard (VDE/DIN) power cables with copper conductors, PVC insulation, and PVC outer sheath. NYY-J includes a green-yellow protective conductor (PE/ground wire) within the cable assembly. NYY-O does not include a ground wire - the "O" stands for "ohne" (German for "without"). Both are unarmoured and designed for indoor or protected installations.
What is the difference between XHHW and THHN cable?
XHHW THHN Cable are both North American standard building wires. THHN (Thermoplastic High Heat-resistant Nylon-coated) uses PVC insulation with a nylon outer layer and is rated for dry locations only. XHHW (Cross-linked Polyethylene High heat-resistant Water-resistant) uses XLPE insulation and is rated for both wet and dry locations, with higher temperature ratings. XHHW is typically used for higher-temperature and outdoor/underground applications.
Hot Tags: low voltage power cable, China low voltage power cable manufacturers, suppliers, factory
You Might Also Like
Send Inquiry