8 Sets 1250kVA On-load Tap-changing Oil-immersed Transformers Customized For The Moldovan Client
Nov 18, 2025
Leave a message
The 1250kVA on-load tap-changing oil-immersed transformer customized for the Moldovan client has been manufactured and tested.
Eight transformers of various specifications ordered by our Moldovan client have been manufactured and tested. They are currently being packed for shipment. This shipment consists of a 40-foot container transported by truck to Qingdao Port in China, from where it will be shipped by sea to the client's final destination.
Transformers bound for Moldova are beingpacked at full speed.

Everyscrew is tightened with a sense of responsibility.

Every layer of protection is taken to the extreme.

Ready to cross mountains and seas to fulfil their overseas mission!

Technical Parameter
Technical Parameter for 6kV, 10kV& 30kVA-2500kVA With Off Circuit Dry Type Transformer
| (KVA)Rated capacity | Voltage Combination | Connection Group Symbol | No-load Loss(W) | Load Loss (W) | No-load Current (%) | Short-circuit Impedance(%) | ||||
| High Voltage (KV) | Tapping ranges of High Voltage | Low Voltage(KV) | 130℃(B) (100℃) | 155℃(F) (120℃) | 180℃(H) (145℃) | |||||
| 30 | 6 6.3 6.6 10 10.5 11 |
±2.5% ±5% |
0.4 | Dyn11 Yyn0 | 190 | 670 | 710 | 760 | 2 | 4 |
| 50 | 270 | 940 | 1000 | 1070 | 2 | |||||
| 80 | 370 | 1290 | 1380 | 1480 | 1.5 | |||||
| 100 | 400 | 1480 | 1570 | 1690 | 1.5 | |||||
| 125 | 470 | 1740 | 1850 | 1980 | 1.3 | |||||
| 160 | 540 | 2000 | 2130 | 2280 | 1.3 | |||||
| 200 | ±2X2.5% ±5% |
620 | 2370 | 2530 | 2710 | 1.1 | ||||
| 250 | 720 | 2590 | 2760 | 2960 | 1.1 | |||||
| 315 | 880 | 3270 | 3470 | 3730 | 1 | |||||
| 400 | 980 | 3750 | 3990 | 4280 | 1 | |||||
| 500 | 1150 | 4590 | 4880 | 5230 | 1 | |||||
| 630 | 1340 | 5530 | 5880 | 6290 | 0.85 | |||||
| 630 | 1300 | 5610 | 5960 | 6400 | 0.85 | 6 | ||||
| 800 | 1520 | 6550 | 6960 | 7460 | 0.85 | |||||
| 1000 | 1770 | 7650 | 8130 | 8760 | 0.85 | |||||
| 1250 | 2090 | 9100 | 9690 | 10300 | 0.85 | |||||
| 1600 | 2450 | 11000 | 11700 | 12500 | 0.85 | |||||
| 2000 | 3050 | 13600 | 14400 | 15500 | 0.7 | |||||
| 2500 | 3600 | 16100 | 17100 | 18400 | 0.7 | |||||
| 1600 | 2450 | 1220 | 12900 | 13900 | 0.85 | 8 | ||||
| 2000 | 3050 | 15000 | 15900 | 17100 | 0.7 | |||||
| 2500 | 3600 | 17700 | 18800 | 20200 | 0.7 | |||||
Technical Parameter for 20kV 50kVA-2500kVA With Off Circuit Dry Type Transformer
| (KVA)Rated capacity | Voltage Combination | Connection Group Symbol | No-load Loss(W) | Load Loss (W) | No-load Current (%) | Short-circuit Impedance(%) | ||||
| High Voltage (KV) | Tapping ranges of High Voltage | Low Voltage(KV) | 130℃(B) (100℃) | 155℃(F) (120℃) | 180℃(H) (145℃) | |||||
| 50 | 20 22 24 |
±2.5% ±5% |
0.4 | Dyn11 Yyn0 | 340 | 1160 | 1230 | 1310 | 2 | 5.0 |
| 100 | 540 | 1870 | 1990 | 2130 | 1.8 | |||||
| 160 | 670 | 2350 | 2470 | 3460 | 1.8 | |||||
| 200 | ±2X2.5% ±5% |
730 | 2770 | 2940 | 3140 | 1.8 | ||||
| 250 | 840 | 3220 | 3420 | 3660 | 1.8 | |||||
| 315 | 970 | 3850 | 4080 | 4360 | 1.8 | |||||
| 400 | 1150 | 4650 | 4840 | 5180 | 1.1 | |||||
| 500 | 1350 | 5460 | 5790 | 6190 | 1.1 | |||||
| 630 | 1530 | 6450 | 6840 | 7320 | 1 | |||||
| 800 | 1750 | 7790 | 8260 | 8840 | 1 | |||||
| 1000 | 2070 | 9220 | 9780 | 10400 | 0.85 | |||||
| 1250 | 2380 | 10800 | 11500 | 12300 | 0.85 | |||||
| 1600 | 2790 | 13000 | 13800 | 14800 | 0.85 | |||||
| 2000 | 3240 | 15400 | 16300 | 17500 | 0.7 | 8.0 | ||||
| 2500 | 3870 | 18200 | 19300 | 20700 | 0.7 | |||||
| 2000 | 3240 | 16800 | 17800 | 19100 | 0.7 | |||||
| 2500 | 3870 | 20000 | 21200 | 22700 | 0.7 | |||||
Technical Parameter for 35kV 50kVA-2500kVA With Off Circuit Dry Type Transformer
| (KVA)Rated capacity | Voltage Combination | Connection Group Symbol | No-load Loss(W) | Load Loss (W) | No-load Current (%) | Short-circuit Impedance(%) | ||||
| High Voltage (KV) | Tapping ranges of High Voltage | Low Voltage(KV) | 130℃(B) (100℃) | 155℃(F) (120℃) | 180℃(H) (145℃) | |||||
| 50 | 35 36 37 38.5 |
±2.5% ±5% |
0.4 | Dyn11 Yyn0 | 450 | 1340 | 1420 | 1520 | 2.3 | 6 |
| 100 | 630 | 1970 | 2090 | 2230 | 2 | |||||
| 160 | 0.79 | 2650 | 2810 | 3000 | 1.5 | |||||
| 200 | ±2X2.5% ±5% |
0.88 | 3130 | 3320 | 3550 | 1.5 | ||||
| 250 | 0.99 | 3580 | 3800 | 4060 | 1.3 | |||||
| 315 | 1170 | 4250 | 4510 | 4820 | 1.3 | |||||
| 400 | 1370 | 5100 | 5410 | 5790 | 1.1 | |||||
| 500 | 1520 | 6270 | 6650 | 7110 | 1.1 | |||||
| 630 | 1860 | 7250 | 7690 | 8230 | 1 | |||||
| 800 | 2160 | 8600 | 9120 | 9760 | 1 | |||||
| 1000 | 2430 | 9860 | 10400 | 11100 | 0.75 | |||||
| 1250 | 2830 | 12000 | 12700 | 13600 | 0.75 | |||||
| 1600 | 3240 | 14600 | 15400 | 16500 | 0.75 | |||||
| 2000 | 3820 | 17200 | 18200 | 19500 | 0.75 | |||||
| 2500 | 4450 | 20600 | 21800 | 23300 | 0.75 | |||||
If you are interested in our products, please contact us or SEND INQUIRY to us, we will reply you within one hour.
Send Inquiry