introduction of 2000kVA pad mounted transformer


 

GNEE TRANSFORMER supplies 2000kVA pad mounted transformer.

2000kVA three phase pad mounted transformer adopts a fully sealed oil-immersed design, which complies with international standards such as IEC, ANSI and GB. It has the characteristics of high efficiency, low loss and strong weather resistance. It is widely used in industrial parks, commercial complexes, power companies and new energy projects, and is particularly suitable for medium and large load environments that require both stable power supply and energy saving.

 

features

  • Sealed tank construction
  • Pad mounted transformer use FR3 high-fire-point dielectric fluid, environmental friendly choice
  • Reliability: The rugged nature and design of pad-mounted transformers allows them to perform flawlessly in harsh weather conditions.
  • Special type design that is to be easy transpotation and installation.
  • Excellent cooling effect by corrugate cooling way and external appearance is beautiful.
  • Safety: The enclosed and durable design of pad-mounted transformers provides the highest level of protection against electric shock and arc flash hazards.

 

2000 kVA Pad Mounted Transformer Specifications
Phase Three phase Std. ANSI/IEEE Std C57 & DOE 2016 Std
Power rating 2000kVA (2MVA) Config Dead front/loop feed
Mounting Pad Mount Frequency 60Hz
HV Voltage 24.94 kV Delta Tap changer 5-position
LV Voltage 480 V Fluid Capacity 416 GAL
HV BIL 125 kV Total weight 12125 LBS
LV BIL 30 kV No load loss 1555 W
Vectorgroup Dyn1 On load loss 13670 W
Cooling method KNAN Impedance 5.50%
Winding Material Aluminum Forced Air (Fans) None
Insulation Fluid Biodegradable vegetable oil Capacity @ 65°C Temperature Rise 2000 kVA
Enclosure Rating NEMA 3R Weatherproof    
 

company profile


 

GNEE TRANSFORMER has strong production capacity and an efficient marketing team.

 

Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,

 

Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.

 

GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.

 

transformer Workshop equipment display


 

Transformer Test equipment
Test equipment
Transformer Test equipment2
Test equipment

 

Oil transformation workshop
Oil transformation workshop
Dry transformation workshop
Dry transformation workshop

 

Transformer Intelligent automatic bending machine
Intelligent automatic bending machine
Transformer Cnc punch press
Cnc punch press

 

Transformer Intelligent laser cutting machine
Intelligent laser cutting machine
Transformer Welding robot
Welding robot

 

Transformer Fully automatic laminating unit
Fully automatic laminating unit
Transformer Fully automatic laminating unit2
Fully automatic laminating unit

 

Transformer Wire winding unit
Wire winding unit
Transformer Wire winding unit2
Wire winding unit
Transformer Wire winding unit3
Wire winding unit
 
 

 

 

 

 

types of transformer from GNEE


 

500kV oil-immersed single-phase double-winding unexcited voltage regulating power transformer

500kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
220kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
66kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
66kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
35kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
35kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
10kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
S(B)H15(21~25)-M sealed amorphous alloy power transformer
SCB three-dimensional core transformer
35kV dry-type non-excitation voltage regulating power transformer
35kV dry-type on-load voltage regulating power transformer
35kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side without excitation voltage regulation
20kV dry-type non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side
SC(B)H15(17~19) amorphous alloy dry type transformer
SG(B)12~18 non-encapsulated H-class dry type transformer
CSD marine transformer
SGB three-dimensional core transformer
New energy transformer
35kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
10kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
Prefabricated cabin substation
Integrated inverter and step-up converter
10000V mine transformer
6000V mine transformer
Buried transformer
Phase-shifting rectifier transformer
Electric furnace transformer
Grounding transformer
QSG/SG three-phase dry isolation transformer
Three-phase pad-mounted transformer
Single-phase pad-mounted transformer
Single-phase pole-mounted transformer

Get Transformer Order specification

GNEE Transformer Order specification

When choosing our company's products, please provide the following data to better serve you.

Demander

Demander:

Telephonemethods:

Fax:

Project technical leader:

Telephonemethods:

Mailbox:

Transformer type selection

□Dry transformer

{□SC(B) Epoxy resin □SC(B) Non-encapsulated}

□American Box(ZGS)

{□Terminal type(-Z-) □Ring network type(-H-)}

□European Box change(YBM){□ Dry change □Oil change}

□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow}

□Amorphous alloy transformer{□Dry amorphous □ Oil amorphous}

□ Special transformer{Rectifier, Furnace, Mine, Etc}

Transformer basic data selection

Country of use:

 

Phase number:

□Three-phase(S conventional) □ Monophase □Other( )

Frequency:

□50Hz(conventional) □60Hz □ Other( )

Transformer oil:

□#25(conventional) □#45(minimum temperature below-25℃)

Rated capacity:

□( )kVA Conditions of use □Outdoor type □Indoor type

Altitude:

□Less than 1000m(conventional) □1000-2000m □3000m以上 over

Rated voltage(High voltage)

□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( )

Rated voltage(Low pressure)

□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( )

Connected group

□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( )

Impedance(%):

□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( )

Voltage regulation mode

□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z)

Voltage regulation range

□±2*2.5% □±5% □±3*2.5% □Other( )

Transformer accessory selection

□Fan □Temperature control{□ Common □With 485 computer interface}

□Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel}

□Protection level of dry case(□IP20(Conventional) □IP( )}

□Dry case height requirements{□None □Requirements[ ]}

□ Cable out mode of the dry variable shell

{□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]}

Note:

1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged

2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee)

Other special requirements(additional charges apply below)

Dry transformer

□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo

□Zero sequence transformer □Copper bar to the low voltage cabinet

□Protective mesh □Lighting □100kVA or less Fan □Shock absorber

Oil-immersed transformer

□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator

□400kVA and below low voltage outlet OABC phase with wiring terminals

□630kVA or below requires temperature control

□800kVA or below Low voltage outlet phase 0 requires wiring terminals

□630kVA and below must be equipped with gas relay

 

GNEE TRANSFORMER Industrial Layout


 

Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan

 

Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa

 

North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica

 

Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom

 

South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile

 

Middle East: The Middle East region

 

Oceania: Australia, Papua New Guinea. Fiji

Hot Tags: 2000kva pad mounted transformer, China 2000kva pad mounted transformer manufacturers, suppliers, factory, documentation of pad mounted transformer, Dry Type Pad Mounted Transformer, high voltage pad mounted transformer, pad mounted transformer dimensions, pad mounted transformer regulations, size of pad mounted transformer

Send Inquiry