
44kV 2MVA Live Front Transformer
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
introduction of 44kV 2MVA Live Front Transformer

GNEE TRANSFORMER supplies 44kV 2MVA Live Front Transformer.
Core Features:
- Compliance with CSA C88 & CSA C227.5 standards
- Anti-tamper design
- Live front type
- High voltage side equipped with lightning arresters, capable of withstanding transient overvoltages up to 118kV
- Low voltage side-out design
- Environmentally friendly, reliable, and fireproof, it uses vegetable oil with a higher ignition point as the insulating fluid, offering excellent insulation performance and a high fireproof rating.
44kV 2MVA Live Front Transformer Technical Specifications | |
POWER RATING | 2MVA |
RATINGPRIMARY VOLTAGE | 44,000 V DELTA |
SECONDARY VOLTAGE | 600GRDY/347V |
FREQUENCY | 60Hz |
VECTOR GROUP | Dyn1 |
WINDING MATERIAL | COPPER |
LOAD LOSS AT RATED VOLTAGE | 16,500W |
NO LOAD LOSSES | 2,600W |
IMPEDANCE | 6.5% AT 2MVA |
ALTITUDE | ≤1000m |
OIL WEIGHT | 2,450L |
TOTAL WEIGHT | 8,420kg |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
When choosing our company's products, please provide the following data to better serve you. |
||
Demander |
||
Demander: |
Telephonemethods: |
Fax: |
Project technical leader: |
Telephonemethods: |
Mailbox: |
Transformer type selection |
||
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
Transformer basic data selection
Country of use: |
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: 44kv 2mva live front transformer, China 44kv 2mva live front transformer manufacturers, suppliers, factory, outdoor pad mounted transformers, pad mounted transformer monitoring, pad mounted transformer regulations, size of pad mounted transformer, transformer for pad mounting, warranty of pad mounted transformer
You Might Also Like
Send Inquiry