220kV 63 MVA three phase oil filled power transformer
Primary Voltage Ratings: 220kV
Secondary Voltage Ratings: 30/11kV
H.V. TAP RANGE: 220kV ±1.25%×10 tapping positions
CONNECTION TYPE: YNyno d11
Power Rating: 47.5MVA, 63 MVA
Cooling Method: ONAN/ONAF
Standards: IEC
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 220kv 63 mva three phase oil filled power transformer in China. If you're going to buy customized 220kv 63 mva three phase oil filled power transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
introduction of 220kV 63 MVA power transformer
GNEE TRANSFORMER supplies 220kV 63 MVA three phase oil filled power transformer.
The 220KV 63MVA 3 Phase Power Transformer is engineered for demanding high-voltage transmission applications in harsh outdoor environments. This advanced unit features a three-winding conservator design and is built to IEC standards for reliability and performance. Its on-load tap changer (OLTC) provides 21 precise tap positions with ±1.25% increments, ensuring optimal voltage regulation over a wide range of operating conditions. Designed for stability under extreme climates-with high ambient temperatures up to 50°C and sub-zero conditions down to -5°C.
This transformer combines robust core construction, high-quality copper windings, and a durable, coated tank to deliver long-term service even in corrosive and tropical environments. Its efficient ONAN/ONAF cooling system guarantees that the unit maintains safe operating temperatures while minimizing energy losses and ensuring consistent performance in critical power distribution networks.
three phase oil filled power transformer Service Conditions:
- Maximum altitude: 1,000 meters above sea level
- Maximum ambient air temperature: +50°C
- Minimum ambient air temperature: -5°C
- Monthly average temperature of the hottest month: 40°C
- Yearly average temperature: 30°C
220kV 63 MVA three phase oil filled power transformer Specifications
|
Rated Power |
63 MVA |
|
Primary Voltage |
220 kV |
|
Secondary Voltage |
30/11 kV |
|
Frequency |
50/60Hz |
|
Tap Changer |
21-position OLTC with ±1.25% step adjustments |
|
Cooling Method |
ONAN/ONAF (Natural oil and forced air cooling) |
|
Connection Type |
YNyno d11 |
|
Transformer Type |
3-phase, three-winding conservator design |
|
Standards Compliance |
Fully IEC compliant |
|
Environmental Endurance |
Designed for operation in extreme conditions (ambient up to +50°C and as low as -5°C, with robust protection against humidity and corrosive elements) |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: 220kv 63 mva three phase oil filled power transformer, China 220kv 63 mva three phase oil filled power transformer manufacturers, suppliers, factory, transformer financing, transformer industry, transformer wiring, transformer recommendation, transformer promotion, transformer calibration
You Might Also Like
Send Inquiry