35MVA 115kV Three-phase Oil-filled Power Transformer
Primary Voltage Ratings: 115kV
Secondary Voltage Ratings: 13.8kV
TYPE: On load tap changer power transformer
Power Rating: 20,500/27,200/35,000kVA
Cooling Method: ONAN/ONAF1/ONAF2
Standards: IEEE
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
Henan GNEE Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of 35mva 115kv three-phase oil-filled power transformer in China. If you're going to buy customized 35mva 115kv three-phase oil-filled power transformer made in China, welcome to get quotation from our factory. Quality products and reasonable price are available.
introduction of 35MVA 115kV Power Transformer
GNEE TRANSFORMER supplies 35MVA 115kV oil immersed power transformer.
The 35MVA 115kV Three-phase Oil-filled Power Transformer is a cutting-edge, high-performance solution for modern power distribution systems, particularly in renewable energy sectors. It offers high efficiency, reliability, and long service life.Its applications include renewable energy projects (such as solar and wind), industrial power distribution, grid stabilization, and high-reliability power systems.
35MVA 115kV Three-phase Oil-filled Power Transformer Features
- Compliance with IEEE C57.12.00: The 35MVA 115kV transformer adheres to international industry standards, ensuring superior quality and performance.
- Low Loss and High Efficiency: Designed with low core and copper losses, this transformer significantly reduces energy consumption, contributing to sustainability and cost-effectiveness.
- Reduced Partial Discharge and Noise: Engineered for low partial discharge (PD) and noise emissions, it ensures a quieter operation while maintaining long-term stability.
- Short-Circuit Resistance: The transformer is designed to withstand high fault currents, improving the overall safety and durability of the system.
- Leakage-Free Design: With robust construction, this transformer is designed to prevent oil leakage, enhancing environmental safety and system reliability.
35MVA 115kV Three-phase Oil-filled Power Transformer Specifications
| RATED POWER | 20.5/27.2/35 MVA |
| RATINGPRIMARY VOLTAGE | 115 kV |
| SECONDARY VOLTAGE | 13.8 kV |
| FREQUENCY | 60Hz |
| VECTOR GROUP | YNd1 |
| WINDING MATERIAL | COPPER |
| LOAD LOSS | 166.9KW |
| NO LOAD LOSSES | 19.86KW |
| IMPEDANCE VOLTAGE | 15.01% |
| ALTITUDE | ≤1260m |
| SERVICE LOCATION | OUTDOOR |
| INSULATING OIL WEIGHT | 1670 GAL |
| TOTAL WEIGHT | 102977 LBS |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: 35mva 115kv three-phase oil-filled power transformer, China 35mva 115kv three-phase oil-filled power transformer manufacturers, suppliers, factory, transformer lease, transformer website, reliable transformer, transformer development, step up transformer, transformer tap changer
You Might Also Like
Send Inquiry