132 KV 60 MVA Oil-immersed Power Transformer
Primary Voltage Ratings: 132 kV
Secondary Voltage Ratings: 11.5 kV
CONNECTION TYPE: DYN11
Power Rating: 60MVA
Standards: IEC
Have questions? GNEE sales representatives are available for live chat now
Send E-mail: sales@gneeelectric.com
Tel: +8615824687445
introduction of 132 kV 60 MVA power transformer
GNEE TRANSFORMER supplies 132 kV 60 MVA three phase oil filled power transformer.
Our 132KV 60MVA 3 Phase Power Transformer is engineered for heavy-duty high-voltage transmission applications in challenging environments. This oil-immersed, conservator-type transformer features a free-breathing design and an on-load tap changer with 17 precise tap settings, each offering a 1.5% voltage adjustment.
Built to exceed IEC standards, it delivers exceptional performance with a controlled temperature rise that stays well within safe limits, even in tropical or corrosive climates. Designed for outdoor deployment, its robust construction, including high-grade winding materials and a welded conservator, guarantees long-term reliability and efficient energy distribution, making it ideal for modern power grids and critical infrastructure projects.
Oil-immersed Power Transformer Applications
- High-Voltage Transmission Networks
Ideal for upgrading transmission grids in regions with severe climate conditions, ensuring continuous, reliable power flow.
- Substation Modernization
Perfectly suited for utility substations where precise voltage control and robust environmental resistance are necessary to support high-demand urban centers.
- Renewable Energy Backbones
Supports large-scale solar and wind farms by providing stable voltage conversion and efficient integration with grid-tied systems.
- Critical Infrastructure Projects
Tailored for energy-intensive installations like industrial complexes and data centers that require resilient power solutions in corrosive or tropical environments.
132 KV 60 MVA Oil-immersed Power Transformer Specifications
|
Rated Power |
60MVA |
|
Primary Voltage |
132KV |
|
Secondary Voltage |
11.5KV |
|
Frequency |
50Hz |
|
Tap Configuration |
17-step on-load tap changer (each step at 1.5% adjustment) |
|
Cooling Method |
ONAN (Natural Air Cooling) |
|
Transformer Type |
Oil-immersed, conservator design with free breathing |
|
Standards Compliance |
Meets IEC standards for safety and performance |
|
Temperature Rise |
50°C above ambient, maintained 10°C below IEC maximum limits |
|
Environmental Protection |
IP55-rated enclosure for resistance to dust and moisture |
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji
Hot Tags: 132 KV 60 MVA Oil-immersed Power Transformer, China 132 KV 60 MVA Oil-immersed Power Transformer manufacturers, suppliers, factory, dry type power transformer, power isolation transformer, power voltage transformer, Substation Power, transformer development, transformer modernization
You Might Also Like
Send Inquiry